Literature DB >> 15587662

Mapping of the prostate in endorectal coil-based MRI/MRSI and CT: a deformable registration and validation study.

J Lian1, L Xing, S Hunjan, C Dumoulin, J Levin, A Lo, R Watkins, K Rohling, R Giaquinto, D Kim, D Spielman, B Daniel.   

Abstract

The endorectal coil is being increasingly used in magnetic resonance imaging (MRI) and MR spectroscopic imaging (MRSI) to obtain anatomic and metabolic images of the prostate with high signal-to-noise ratio (SNR). In practice, however, the use of endorectal probe inevitably distorts the prostate and other soft tissue organs, making the analysis and the use of the acquired image data in treatment planning difficult. The purpose of this work is to develop a deformable image registration algorithm to map the MRI/MRSI information obtained using an endorectal probe onto CT images and to verify the accuracy of the registration by phantom and patient studies. A mapping procedure involved using a thin plate spline (TPS) transformation was implemented to establish voxel-to-voxel correspondence between a reference image and a floating image with deformation. An elastic phantom with a number of implanted fiducial markers was designed for the validation of the quality of the registration. Radiographic images of the phantom were obtained before and after a series of intentionally introduced distortions. After mapping the distorted phantom to the original one, the displacements of the implanted markers were measured with respect to their ideal positions and the mean error was calculated. In patient studies, CT images of three prostate patients were acquired, followed by 3 Tesla (3 T) MR images with a rigid endorectal coil. Registration quality was estimated by the centroid position displacement and image coincidence index (CI). Phantom and patient studies show that TPS-based registration has achieved significantly higher accuracy than the previously reported method based on a rigid-body transformation and scaling. The technique should be useful to map the MR spectroscopic dataset acquired with ER probe onto the treatment planning CT dataset to guide radiotherapy planning.

Entities:  

Mesh:

Year:  2004        PMID: 15587662     DOI: 10.1118/1.1806292

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  22 in total

1.  Image-based modeling of tumor shrinkage in head and neck radiation therapy.

Authors:  Ming Chao; Yaoqin Xie; Eduardo G Moros; Quynh-Thu Le; Lei Xing
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

2.  Objective assessment of deformable image registration in radiotherapy: a multi-institution study.

Authors:  Rojano Kashani; Martina Hub; James M Balter; Marc L Kessler; Lei Dong; Lifei Zhang; Lei Xing; Yaoqin Xie; David Hawkes; Julia A Schnabel; Jamie McClelland; Sarang Joshi; Quan Chen; Weiguo Lu
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

3.  Feature-based rectal contour propagation from planning CT to cone beam CT.

Authors:  Yaoqin Xie; Ming Chao; Percy Lee; Lei Xing
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

4.  A Domain Constrained Deformable (DoCD) Model for Co-registration of Pre- and Post-Radiated Prostate MRI.

Authors:  Robert Toth; Bryan Traughber; Rodney Ellis; John Kurhanewicz; Anant Madabhushi
Journal:  Neurocomputing       Date:  2014-11-20       Impact factor: 5.719

5.  Accuracy of deformable image registration on magnetic resonance images in digital and physical phantoms.

Authors:  Rachel B Ger; Jinzhong Yang; Yao Ding; Megan C Jacobsen; Clifton D Fuller; Rebecca M Howell; Heng Li; R Jason Stafford; Shouhao Zhou; Laurence E Court
Journal:  Med Phys       Date:  2017-07-18       Impact factor: 4.071

6.  Multimodal image registration for the identification of dominant intraprostatic lesion in high-precision radiotherapy treatments.

Authors:  Delia Ciardo; Barbara Alicja Jereczek-Fossa; Giuseppe Petralia; Giorgia Timon; Dario Zerini; Raffaella Cambria; Elena Rondi; Federica Cattani; Alessia Bazani; Rosalinda Ricotti; Maria Garioni; Davide Maestri; Giulia Marvaso; Paola Romanelli; Marco Riboldi; Guido Baroni; Roberto Orecchia
Journal:  Br J Radiol       Date:  2017-08-22       Impact factor: 3.039

7.  Volume and landmark analysis: comparison of MRI measurements obtained with an endorectal coil and with a phased-array coil.

Authors:  Y Mazaheri; A A Afaq; S I Jung; D A Goldman; L Wang; H Aslan; M J Zelefsky; O Akin; H Hricak
Journal:  Clin Radiol       Date:  2014-12-29       Impact factor: 2.350

8.  Three-dimensional elastic image registration based on strain energy minimization: application to prostate magnetic resonance imaging.

Authors:  Bao Zhang; Dwayne D Arola; Steve Roys; Rao P Gullapalli
Journal:  J Digit Imaging       Date:  2011-08       Impact factor: 4.056

9.  A registration based approach for 4D cardiac micro-CT using combined prospective and retrospective gating.

Authors:  Cristian T Badea; Eduard Schreibmann; Tim Fox
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

Review 10.  Role of magnetic resonance methods in the evaluation of prostate cancer: an Indian perspective.

Authors:  Naranamangalam R Jagannathan; Virendra Kumar; Rajeev Kumar; Sanjay Thulkar
Journal:  MAGMA       Date:  2008-07-17       Impact factor: 2.310

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.