Literature DB >> 22796656

Tracking the motion trajectories of junction structures in 4D CT images of the lung.

Guanglei Xiong1, Chuangzhen Chen, Jianzhou Chen, Yaoqin Xie, Lei Xing.   

Abstract

Respiratory motion poses a major challenge in lung radiotherapy. Based on 4D CT images, a variety of intensity-based deformable registration techniques have been proposed to study the pulmonary motion. However, the accuracy achievable with these approaches can be sub-optimal because the deformation is defined globally in space. Therefore, the accuracy of the alignment of local structures may be compromised. In this work, we propose a novel method to detect a large collection of natural junction structures in the lung and use them as the reliable markers to track the lung motion. Specifically, detection of the junction centers and sizes is achieved by analysis of local shape profiles on one segmented image. To track the temporal trajectory of a junction, the image intensities within a small region of interest surrounding the center are selected as its signature. Under the assumption of the cyclic motion, we describe the trajectory by a closed B-spline curve and search for the control points by maximizing a metric of combined correlation coefficients. Local extrema are suppressed by improving the initial conditions using random walks from pair-wise optimizations. Several descriptors are introduced to analyze the motion trajectories. Our method was applied to 13 real 4D CT images. More than 700 junctions in each case are detected with an average positive predictive value of greater than 90%. The average tracking error between automated and manual tracking is sub-voxel and smaller than the published results using the same set of data.

Entities:  

Mesh:

Year:  2012        PMID: 22796656      PMCID: PMC7552994          DOI: 10.1088/0031-9155/57/15/4905

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  43 in total

1.  Semi-automatic construction of reference standards for evaluation of image registration.

Authors:  K Murphy; B van Ginneken; S Klein; M Staring; B J de Hoop; M A Viergever; J P W Pluim
Journal:  Med Image Anal       Date:  2010-08-03       Impact factor: 8.545

2.  Multiframe temporal estimation of cardiac nonrigid motion.

Authors:  J C McEachen; A Nehorai; J S Duncan
Journal:  IEEE Trans Image Process       Date:  2000       Impact factor: 10.856

3.  Diffeomorphic demons: efficient non-parametric image registration.

Authors:  Tom Vercauteren; Xavier Pennec; Aymeric Perchant; Nicholas Ayache
Journal:  Neuroimage       Date:  2008-11-07       Impact factor: 6.556

4.  Image matching as a diffusion process: an analogy with Maxwell's demons.

Authors:  J P Thirion
Journal:  Med Image Anal       Date:  1998-09       Impact factor: 8.545

5.  Spatiotemporal motion estimation for respiratory-correlated imaging of the lungs.

Authors:  Jef Vandemeulebroucke; Simon Rit; Jan Kybic; Patrick Clarysse; David Sarrut
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

6.  Registration of 4D cardiac CT sequences under trajectory constraints with multichannel diffeomorphic demons.

Authors:  Jean-Marc Peyrat; Hervé Delingette; Maxime Sermesant; Chenyang Xu; Nicholas Ayache
Journal:  IEEE Trans Med Imaging       Date:  2010-03-18       Impact factor: 10.048

7.  Four-dimensional deformable image registration using trajectory modeling.

Authors:  Edward Castillo; Richard Castillo; Josue Martinez; Maithili Shenoy; Thomas Guerrero
Journal:  Phys Med Biol       Date:  2010-01-07       Impact factor: 3.609

8.  A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing.

Authors:  Daniel A Low; Michelle Nystrom; Eugene Kalinin; Parag Parikh; James F Dempsey; Jeffrey D Bradley; Sasa Mutic; Sasha H Wahab; Tareque Islam; Gary Christensen; David G Politte; Bruce R Whiting
Journal:  Med Phys       Date:  2003-06       Impact factor: 4.071

9.  Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy.

Authors:  Yvette Seppenwoolde; Hiroki Shirato; Kei Kitamura; Shinichi Shimizu; Marcel van Herk; Joos V Lebesque; Kazuo Miyasaka
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-07-15       Impact factor: 7.038

10.  4D-CT lung motion estimation with deformable registration: quantification of motion nonlinearity and hysteresis.

Authors:  Vlad Boldea; Gregory C Sharp; Steve B Jiang; David Sarrut
Journal:  Med Phys       Date:  2008-03       Impact factor: 4.071

View more
  3 in total

1.  Sequential Monte Carlo tracking of the marginal artery by multiple cue fusion and random forest regression.

Authors:  Kevin M Cherry; Brandon Peplinski; Lauren Kim; Shijun Wang; Le Lu; Weidong Zhang; Jianfei Liu; Zhuoshi Wei; Ronald M Summers
Journal:  Med Image Anal       Date:  2014-10-13       Impact factor: 8.545

2.  Contour propagation using non-uniform cubic B-splines for lung tumor delineation in 4D-CT.

Authors:  Yongchuan Liu; Renchao Jin; Mi Chen; Enmin Song; Xiangyang Xu; Sheng Zhang; Chih-Cheng Hung
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-07-16       Impact factor: 2.924

3.  3D Magnetic Resonance Spirometry.

Authors:  Tanguy Boucneau; Brice Fernandez; Peder Larson; Luc Darrasse; Xavier Maître
Journal:  Sci Rep       Date:  2020-06-15       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.