Literature DB >> 33412481

Tissue-specific deformable image registration using a spatial-contextual filter.

Yongbin Zhang1, Lifei Zhang2, Laurence E Court2, Peter Balter2, Lei Dong3, Jinzhong Yang4.   

Abstract

Intensity-based deformable registration with spatial-invariant regularization generally fails when distinct motion exists across different types of tissues. The purpose of this work was to develop and validate a new regularization approach for deformable image registration that is tissue-specific and able to handle motion discontinuities. Our approach was built upon a Demons registration framework, and used the image context supplementing the original spatial constraint to regularize displacement vector fields in iterative image registration process. The new regularization was implemented as a spatial-contextual filter, which favors the motion vectors within the same tissue type but penalizes the motion vectors from different tissues. This approach was validated using five public lung cancer patients, each with 300 landmark pairs identified by a thoracic radiation oncologist. The mean and standard deviation of the landmark registration errors were 1.3 ± 0.8 mm, compared with those of 2.3 ± 2.9 mm using the original Demons algorithm. Particularly, for the case with the largest initial landmark displacement of 15 ± 9 mm, the modified Demons algorithm had a registration error of 1.3 ± 1.1 mm, while the original Demons algorithm had a registration error of 3.6 ± 5.9 mm. We also qualitatively evaluated the modified Demons algorithm using two difficult cases in our routine clinic: one lung case with large sliding motion and one head and neck case with large anatomical changes in air cavity. Visual evaluation on the deformed image created by the deformable image registration showed that the modified Demons algorithm achieved reasonable registration accuracy, but the original Demons algorithm produced distinct registration errors.
Copyright © 2020 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Deformable image registration; Lung sliding motion; Spatial-contextual filter

Mesh:

Year:  2020        PMID: 33412481      PMCID: PMC7902440          DOI: 10.1016/j.compmedimag.2020.101849

Source DB:  PubMed          Journal:  Comput Med Imaging Graph        ISSN: 0895-6111            Impact factor:   4.790


  23 in total

Review 1.  Computational vision and regularization theory.

Authors:  T Poggio; V Torre; C Koch
Journal:  Nature       Date:  1985 Sep 26-Oct 2       Impact factor: 49.962

2.  Dosimetric impact of esophagus motion in single fraction spine stereotactic body radiotherapy.

Authors:  Xin Wang; Jinzhong Yang; Zhongxiang Zhao; Dershan Luo; Laurence Court; Yongbin Zhang; David Weksberg; Paul D Brown; Jing Li; Amol J Ghia
Journal:  Phys Med Biol       Date:  2019-05-29       Impact factor: 3.609

3.  Cardiac atlas development and validation for automatic segmentation of cardiac substructures.

Authors:  Rongrong Zhou; Zhongxing Liao; Tinsu Pan; Sarah A Milgrom; Chelsea C Pinnix; Anhui Shi; Linglong Tang; Ju Yang; Ying Liu; Daniel Gomez; Quynh-Nhu Nguyen; Bouthaina S Dabaja; Laurence Court; Jinzhong Yang
Journal:  Radiother Oncol       Date:  2016-12-08       Impact factor: 6.280

4.  Prospective observer and software-based assessment of magnetic resonance imaging quality in head and neck cancer: Should standard positioning and immobilization be required for radiation therapy applications?

Authors:  Yao Ding; Abdallah S R Mohamed; Jinzhong Yang; Rivka R Colen; Steven J Frank; Jihong Wang; Eslam Y Wassal; Wenjie Wang; Michael E Kantor; Peter A Balter; David I Rosenthal; Stephen Y Lai; John D Hazle; Clifton D Fuller
Journal:  Pract Radiat Oncol       Date:  2014-12-17

5.  Digital reconstruction of high-quality daily 4D cone-beam CT images using prior knowledge of anatomy and respiratory motion.

Authors:  Yongbin Zhang; Jinzhong Yang; Lifei Zhang; Laurence E Court; Song Gao; Peter A Balter; Lei Dong
Journal:  Comput Med Imaging Graph       Date:  2014-10-29       Impact factor: 4.790

6.  Automated segmentation of a motion mask to preserve sliding motion in deformable registration of thoracic CT.

Authors:  Jef Vandemeulebroucke; Olivier Bernard; Simon Rit; Jan Kybic; Patrick Clarysse; David Sarrut
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

7.  Modeling respiratory motion for reducing motion artifacts in 4D CT images.

Authors:  Yongbin Zhang; Jinzhong Yang; Lifei Zhang; Laurence E Court; Peter A Balter; Lei Dong
Journal:  Med Phys       Date:  2013-04       Impact factor: 4.071

8.  Constrained non-rigid registration for use in image-guided adaptive radiotherapy.

Authors:  W H Greene; S Chelikani; K Purushothaman; J P S Knisely; Z Chen; X Papademetris; L H Staib; J S Duncan
Journal:  Med Image Anal       Date:  2009-07-16       Impact factor: 8.545

9.  Performance evaluation of automatic anatomy segmentation algorithm on repeat or four-dimensional computed tomography images using deformable image registration method.

Authors:  He Wang; Adam S Garden; Lifei Zhang; Xiong Wei; Anesa Ahamad; Deborah A Kuban; Ritsuko Komaki; Jennifer O'Daniel; Yongbin Zhang; Radhe Mohan; Lei Dong
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-09-01       Impact factor: 7.038

10.  Tissue feature-based and segmented deformable image registration for improved modeling of shear movement of lungs.

Authors:  Yaoqin Xie; Ming Chao; Lei Xing
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-07-15       Impact factor: 7.038

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.