Literature DB >> 15895570

Four-dimensional computed tomography: image formation and clinical protocol.

Eike Rietzel1, Tinsu Pan, George T Y Chen.   

Abstract

Respiratory motion can introduce significant errors in radiotherapy. Conventional CT scans as commonly used for treatment planning can include severe motion artifacts that result from interplay effects between the advancing scan plane and object motion. To explicitly include organ/target motion in treatment planning and delivery, time-resolved CT data acquisition (4D Computed Tomography) is needed. 4DCT can be accomplished by oversampled CT data acquisition at each slice. During several CT tube rotations projection data are collected in axial cine mode for the duration of the patient's respiratory cycle (plus the time needed for a full CT gantry rotation). Multiple images are then reconstructed per slice that are evenly distributed over the acquisition time. Each of these images represents a different anatomical state during a respiratory cycle. After data acquisition at one couch position is completed, x rays are turned off and the couch advances to begin data acquisition again until full coverage of the scan length has been obtained. Concurrent to CT data acquisition the patient's abdominal surface motion is recorded in precise temporal correlation. To obtain CT volumes at different respiratory states, reconstructed images are sorted into different spatio-temporally coherent volumes based on respiratory phase as obtained from the patient's surface motion. During binning, phase tolerances are chosen to obtain complete volumetric information since images at different couch positions are reconstructed at different respiratory phases. We describe 4DCT image formation and associated experiments that characterize the properties of 4DCT. Residual motion artifacts remain due to partial projection effects. Temporal coherence within resorted 4DCT volumes is dominated by the number of reconstructed images per slice. The more images are reconstructed, the smaller phase tolerances can be for retrospective sorting. From phantom studies a precision of about 2.5 mm for quasiregular motion and typical respiratory periods could be concluded. A protocol for 4DCT scanning was evaluated and clinically implemented at the MGH. Patient data are presented to elucidate how additional patient specific parameters can impact 4DCT imaging.

Entities:  

Mesh:

Year:  2005        PMID: 15895570     DOI: 10.1118/1.1869852

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  105 in total

1.  Four-dimensional magnetic resonance imaging (4D-MRI) using image-based respiratory surrogate: a feasibility study.

Authors:  Jing Cai; Zheng Chang; Zhiheng Wang; William Paul Segars; Fang-Fang Yin
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

2.  A novel technique for markerless, self-sorted 4D-CBCT: feasibility study.

Authors:  Irina Vergalasova; Jing Cai; Fang-Fang Yin
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

3.  Extraction of tumor motion trajectories using PICCS-4DCBCT: a validation study.

Authors:  Zhihua Qi; Guang-Hong Chen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

4.  Reduction of irregular breathing artifacts in respiration-correlated CT images using a respiratory motion model.

Authors:  Agung Hertanto; Qinghui Zhang; Yu-Chi Hu; Oleksandr Dzyubak; Andreas Rimner; Gig S Mageras
Journal:  Med Phys       Date:  2012-06       Impact factor: 4.071

5.  Thoracic target volume delineation using various maximum-intensity projection computed tomography image sets for radiotherapy treatment planning.

Authors:  David A Zamora; Adam C Riegel; Xiaojun Sun; Peter Balter; George Starkschall; Osama Mawlawi; Tinsu Pan
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

6.  Assessment of regional ventilation and deformation using 4D-CT imaging for healthy human lungs during tidal breathing.

Authors:  Nariman Jahani; Sanghun Choi; Jiwoong Choi; Krishna Iyer; Eric A Hoffman; Ching-Long Lin
Journal:  J Appl Physiol (1985)       Date:  2015-08-27

7.  Development of a novel post-processing treatment planning platform for 4D radiotherapy.

Authors:  Lan Lin; Chengyu Shi; Yaxi Liu; Gregory Swanson; Nikos Papanikolaou
Journal:  Technol Cancer Res Treat       Date:  2008-04

8.  Iterative sorting for four-dimensional CT images based on internal anatomy motion.

Authors:  Rongping Zeng; Jeffrey A Fessler; James M Balter; Peter A Balter
Journal:  Med Phys       Date:  2008-03       Impact factor: 4.071

9.  4D-CT motion estimation using deformable image registration and 5D respiratory motion modeling.

Authors:  Deshan Yang; Wei Lu; Daniel A Low; Joseph O Deasy; Andrew J Hope; Issam El Naqa
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

10.  Respiratory effort correction strategies to improve the reproducibility of lung expansion measurements.

Authors:  Kaifang Du; Joseph M Reinhardt; Gary E Christensen; Kai Ding; John E Bayouth
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.