A Fabry-Perot fiber-optic ultrasonic hydrophone for the simultaneous measurement of temperature and acoustic pressure.

Paul Morris1, Andrew Hurrell, Adam Shaw, Edward Zhang, Paul Beard.   

Abstract

A dual sensing fiber-optic hydrophone that can make simultaneous measurements of acoustic pressure and temperature at the same location has been developed for characterizing ultrasound fields and ultrasound-induced heating. The transduction mechanism is based on the detection of acoustically- and thermally-induced thickness changes in a polymer film Fabry-Perot interferometer deposited at the tip of a single mode optical fiber. The sensor provides a peak noise-equivalent pressure of 15 kPa (at 5 MHz, over a 20 MHz measurement bandwidth), an acoustic bandwidth of 50 MHz, and an optically defined element size of 10 microm. As well as measuring acoustic pressure, temperature changes up to 70 degrees C can be measured, with a resolution of 0.34 degrees C. To evaluate the thermal measurement capability of the sensor, measurements were made at the focus of a high-intensity focused ultrasound (HIFU) field in a tissue mimicking phantom. These showed that the sensor is not susceptible to viscous heating, is able to withstand high intensity fields, and can simultaneously acquire acoustic waveforms while monitoring induced temperature rises. These attributes, along with flexibility, small physical size (OD approximately 150 microm), immunity to Electro-Magnetic Interference (EMI), and low sensor cost, suggest that this type of hydrophone may provide a practical alternative to piezoelectric based hydrophones.

Entities:  

Mesh:

Year:  2009        PMID: 19507943     DOI: 10.1121/1.3117437

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  42 in total

1.  A comparison of light spot hydrophone and fiber optic probe hydrophone for lithotripter field characterization.

Authors:  N Smith; G N Sankin; W N Simmons; R Nanke; J Fehre; P Zhong
Journal:  Rev Sci Instrum       Date:  2012-01       Impact factor: 1.523

2.  Considerations for Choosing Sensitive Element Size for Needle and Fiber-Optic Hydrophones-Part I: Spatiotemporal Transfer Function and Graphical Guide.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-10       Impact factor: 2.725

3.  Improved measurement of acoustic output using complex deconvolution of hydrophone sensitivity.

Authors:  Keith A Wear; Paul M Gammell; Subha Maruvada; Yunbo Liu; Gerald R Harris
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-01       Impact factor: 2.725

4.  Variation of High-Intensity Therapeutic Ultrasound (HITU) Pressure Field Characterization: Effects of Hydrophone Choice, Nonlinearity, Spatial Averaging and Complex Deconvolution.

Authors:  Yunbo Liu; Keith A Wear; Gerald R Harris
Journal:  Ultrasound Med Biol       Date:  2017-07-21       Impact factor: 2.998

5.  An adaptive filtered back-projection for photoacoustic image reconstruction.

Authors:  He Huang; Gilbert Bustamante; Ralph Peterson; Jing Yong Ye
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

6.  Correction for frequency-dependent hydrophone response to nonlinear pressure waves using complex deconvolution and rarefactional filtering: application with fiber optic hydrophones.

Authors:  Keith Wear; Yunbo Liu; Paul M Gammell; Subha Maruvada; Gerald R Harris
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-01       Impact factor: 2.725

7.  Rapid quantitative imaging of high intensity ultrasonic pressure fields.

Authors:  Huiwen Luo; Jiro Kusunose; Gianmarco Pinton; Charles F Caskey; William A Grissom
Journal:  J Acoust Soc Am       Date:  2020-08       Impact factor: 1.840

8.  Ultrasound insertion loss of rat parietal bone appears to be proportional to animal mass at submegahertz frequencies.

Authors:  Meaghan A O'Reilly; Aidan Muller; Kullervo Hynynen
Journal:  Ultrasound Med Biol       Date:  2011-09-16       Impact factor: 2.998

9.  Directivity and Frequency-Dependent Effective Sensitive Element Size of a Reflectance-Based Fiber-Optic Hydrophone: Predictions From Theoretical Models Compared With Measurements.

Authors:  Keith A Wear; Samuel M Howard
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-10-01       Impact factor: 2.725

Review 10.  Optical Detection of Ultrasound in Photoacoustic Imaging.

Authors:  Biqin Dong; Cheng Sun; Hao F Zhang
Journal:  IEEE Trans Biomed Eng       Date:  2016-09-01       Impact factor: 4.538

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.