Literature DB >> 19469674

The chemistry of commercial continuous glucose monitors.

Geoffrey McGarraugh1.   

Abstract

The analytical methodologies of the continuous glucose monitors (CGMs) commercialized to date are described. The devices include two noninvasive products: the GlucoWatch (Cygnus, Redwood City, CA) G2 Biographer uses iontophoresis to obtain a sample and electrochemistry for glucose detection, and PENDRA (Pendragon Medical Ltd., Zurich, Switzerland) utilizes impedance spectroscopy. Three minimally invasive systems employ subcutaneous amperometric sensors-Guardian REAL-Time (Medtronic MiniMed, Sylmar, CA), DexCom STS-7 (DexCom, San Diego, CA), and FreeStyle Navigator (Abbott Diabetes Care, Alameda, CA). The GlucoDay (A. Menarini I.F.R. S.r.l., Florence, Italy) collects a sample with a minimally invasive microdialysis fiber and measures the glucose electrochemically.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19469674     DOI: 10.1089/dia.2008.0133

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  40 in total

1.  Non-invasive continuous glucose monitoring: improved accuracy of point and trend estimates of the Multisensor system.

Authors:  Mattia Zanon; Giovanni Sparacino; Andrea Facchinetti; Michela Riz; Mark S Talary; Roland E Suri; Andreas Caduff; Claudio Cobelli
Journal:  Med Biol Eng Comput       Date:  2012-06-22       Impact factor: 2.602

2.  Continuous glucose monitoring in the subcutaneous tissue over a 14-day sensor wear period.

Authors:  Udo Hoss; Erwin S Budiman; Hanqing Liu; Mark P Christiansen
Journal:  J Diabetes Sci Technol       Date:  2013-09-01

3.  Signal processing algorithms implementing the "smart sensor" concept to improve continuous glucose monitoring in diabetes.

Authors:  Andrea Facchinetti; Giovanni Sparacino; Claudio Cobelli
Journal:  J Diabetes Sci Technol       Date:  2013-09-01

4.  The design and development of fluorescent nano-optodes for in vivo glucose monitoring.

Authors:  Mary K Balaconis; Kelvin Billingsley; Matthew J Dubach; Kevin J Cash; Heather A Clark
Journal:  J Diabetes Sci Technol       Date:  2011-01-01

5.  An analysis of the SEVEN system: have we reached the summit of needle-type sensor accuracy?

Authors:  Iris M E Wentholt; J Hans DeVries
Journal:  J Diabetes Sci Technol       Date:  2009-09-01

Review 6.  Hypo- and Hyperglycemic Alarms: Devices and Algorithms.

Authors:  Daniel Howsmon; B Wayne Bequette
Journal:  J Diabetes Sci Technol       Date:  2015-04-30

7.  Home use of a bihormonal bionic pancreas versus insulin pump therapy in adults with type 1 diabetes: a multicentre randomised crossover trial.

Authors:  Firas H El-Khatib; Courtney Balliro; Mallory A Hillard; Kendra L Magyar; Laya Ekhlaspour; Manasi Sinha; Debbie Mondesir; Aryan Esmaeili; Celia Hartigan; Michael J Thompson; Samir Malkani; J Paul Lock; David M Harlan; Paula Clinton; Eliana Frank; Darrell M Wilson; Daniel DeSalvo; Lisa Norlander; Trang Ly; Bruce A Buckingham; Jamie Diner; Milana Dezube; Laura A Young; April Goley; M Sue Kirkman; John B Buse; Hui Zheng; Rajendranath R Selagamsetty; Edward R Damiano; Steven J Russell
Journal:  Lancet       Date:  2016-12-20       Impact factor: 79.321

8.  Factory-Calibrated Continuous Glucose Sensors: The Science Behind the Technology.

Authors:  Udo Hoss; Erwin Satrya Budiman
Journal:  Diabetes Technol Ther       Date:  2017-05       Impact factor: 6.118

9.  In Vitro Sugar Interference Testing With Amperometric Glucose Oxidase Sensors.

Authors:  Ryan Boehm; John Donovan; Disha Sheth; Andrew Durfor; Jason Roberts; Irada Isayeva
Journal:  J Diabetes Sci Technol       Date:  2018-08-03

10.  GlucoMen Day continuous glucose monitoring system: a screening for enzymatic and electrochemical interferents.

Authors:  Fausto Lucarelli; Francesco Ricci; Felice Caprio; Francesco Valgimigli; Cosimo Scuffi; Danila Moscone; Giuseppe Palleschi
Journal:  J Diabetes Sci Technol       Date:  2012-09-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.