An analysis of the SEVEN system: have we reached the summit of needle-type sensor accuracy?

Iris M E Wentholt1, J Hans DeVries.   

Abstract

In this issue of Journal of Diabetes Science and Technology, Zisser and colleagues show improved sensor accuracy with the newest generation of needle-type sensors as compared to first generation sensors. Can we expect further improvement? It is unknown what the future holds, but there certainly seems much to be gained from improved calibration procedures. In addition, sensor operating times are increasing and it is hoped that this will translate into improved sensor use and thereby into improved glycemic control. 2009 Diabetes Technology Society.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 20144430      PMCID: PMC2769899          DOI: 10.1177/193229680900300520

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  6 in total

1.  A critical appraisal of the continuous glucose-error grid analysis.

Authors:  Iris M Wentholt; Joost B Hoekstra; J Hans Devries
Journal:  Diabetes Care       Date:  2006-08       Impact factor: 19.112

2.  Relationship of fasting and hourly blood glucose levels to HbA1c values: safety, accuracy, and improvements in glucose profiles obtained using a 7-day continuous glucose sensor.

Authors:  Satish Garg; Lois Jovanovic
Journal:  Diabetes Care       Date:  2006-12       Impact factor: 19.112

3.  The chemistry of commercial continuous glucose monitors.

Authors:  Geoffrey McGarraugh
Journal:  Diabetes Technol Ther       Date:  2009-06       Impact factor: 6.118

4.  Accuracy of the SEVEN continuous glucose monitoring system: comparison with frequently sampled venous glucose measurements.

Authors:  Howard C Zisser; Timothy S Bailey; Sherwyn Schwartz; Robert E Ratner; Jonathan Wise
Journal:  J Diabetes Sci Technol       Date:  2009-09-01

5.  Continuous glucose monitoring and intensive treatment of type 1 diabetes.

Authors:  William V Tamborlane; Roy W Beck; Bruce W Bode; Bruce Buckingham; H Peter Chase; Robert Clemons; Rosanna Fiallo-Scharer; Larry A Fox; Lisa K Gilliam; Irl B Hirsch; Elbert S Huang; Craig Kollman; Aaron J Kowalski; Lori Laffel; Jean M Lawrence; Joyce Lee; Nelly Mauras; Michael O'Grady; Katrina J Ruedy; Michael Tansey; Eva Tsalikian; Stuart Weinzimer; Darrell M Wilson; Howard Wolpert; Tim Wysocki; Dongyuan Xing
Journal:  N Engl J Med       Date:  2008-09-08       Impact factor: 91.245

6.  Continuous glucose sensing: future technology developments.

Authors:  Jim Brauker
Journal:  Diabetes Technol Ther       Date:  2009-06       Impact factor: 6.118

  6 in total
  2 in total

1.  Factors influencing the effectiveness of glucagon for preventing hypoglycemia.

Authors:  Jessica R Castle; Julia M Engle; Joseph El Youssef; Ryan G Massoud; W Kenneth Ward
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

2.  Pilot study of a prototype minimally invasive intradermal continuous glucose monitor.

Authors:  Ruth S Weinstock; Suzan Bristol; Andrew Armenia; A Chris Gesswein; B Wayne Bequette; John P Willis
Journal:  J Diabetes Sci Technol       Date:  2012-11-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.