Factory-Calibrated Continuous Glucose Sensors: The Science Behind the Technology.

Udo Hoss1, Erwin Satrya Budiman1.   

Abstract

The use of commercially available continuous glucose monitors for diabetes management requires sensor calibrations, which until recently are exclusively performed by the patient. A new development is the implementation of factory calibration for subcutaneous glucose sensors, which eliminates the need for user calibrations and the associated blood glucose tests. Factory calibration means that the calibration process is part of the sensor manufacturing process and performed under controlled laboratory conditions. The ability to move from a user calibration to factory calibration is based on several technical requirements related to sensor stability and the robustness of the sensor manufacturing process. The main advantages of factory calibration over the conventional user calibration are: (a) more convenience for the user, since no more fingersticks are required for calibration and (b) elimination of use errors related to the execution of the calibration process, which can lead to sensor inaccuracies. The FreeStyle Libre™ and FreeStyle Libre Pro™ flash continuous glucose monitoring systems are the first commercially available sensor systems using factory-calibrated sensors. For these sensor systems, no user calibrations are required throughout the sensor wear duration.

Entities:  

Keywords:  Calibration; Continuous Glucose Monitoring; Factory calibration; Glucose sensor; Subcutaneous

Mesh:

Substances:

Year:  2017        PMID: 28541139      PMCID: PMC5444502          DOI: 10.1089/dia.2017.0025

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  52 in total

Review 1.  Characterization of implantable biosensor membrane biofouling.

Authors:  N Wisniewski; F Moussy; W M Reichert
Journal:  Fresenius J Anal Chem       Date:  2000 Mar-Apr

2.  Calibration of a subcutaneous amperometric glucose sensor implanted for 7 days in diabetic patients. Part 2. Superiority of the one-point calibration method.

Authors:  C Choleau; J C Klein; G Reach; B Aussedat; V Demaria-Pesce; G S Wilson; R Gifford; W K Ward
Journal:  Biosens Bioelectron       Date:  2002-08       Impact factor: 10.618

3.  Accuracy of the Sof-sensor glucose sensor with the iPro calibration algorithm.

Authors:  John B Welsh; Francine R Kaufman; Scott W Lee
Journal:  J Diabetes Sci Technol       Date:  2012-03-01

4.  CGM--a technology in evolution.

Authors:  Jay S Skyler
Journal:  Diabetes Technol Ther       Date:  2009-02       Impact factor: 6.118

5.  Continuous glucose monitoring in the subcutaneous tissue over a 14-day sensor wear period.

Authors:  Udo Hoss; Erwin S Budiman; Hanqing Liu; Mark P Christiansen
Journal:  J Diabetes Sci Technol       Date:  2013-09-01

Review 6.  Factors affecting blood glucose monitoring: sources of errors in measurement.

Authors:  Barry H Ginsberg
Journal:  J Diabetes Sci Technol       Date:  2009-07-01

7.  Continuous subcutaneous glucose monitoring in children with type 1 diabetes.

Authors:  H P Chase; L M Kim; S L Owen; T A MacKenzie; G J Klingensmith; R Murtfeldt; S K Garg
Journal:  Pediatrics       Date:  2001-02       Impact factor: 7.124

Review 8.  System accuracy of blood glucose monitoring systems: impact of use by patients and ambient conditions.

Authors:  Christina Schmid; Cornelia Haug; Lutz Heinemann; Guido Freckmann
Journal:  Diabetes Technol Ther       Date:  2013-07-24       Impact factor: 6.118

9.  Reconstruction of glucose in plasma from interstitial fluid continuous glucose monitoring data: role of sensor calibration.

Authors:  Andrea Facchinetti; Giovanni Sparacino; Claudio Cobelli
Journal:  J Diabetes Sci Technol       Date:  2007-09

10.  From Two to One Per Day Calibration of Dexcom G4 Platinum by a Time-Varying Day-Specific Bayesian Prior.

Authors:  Giada Acciaroli; Martina Vettoretti; Andrea Facchinetti; Giovanni Sparacino; Claudio Cobelli
Journal:  Diabetes Technol Ther       Date:  2016-08       Impact factor: 6.118

View more
  33 in total

1.  Flash Glucose Monitoring: The Future Is Here.

Authors:  Satish K Garg; Halis Kaan Akturk
Journal:  Diabetes Technol Ther       Date:  2017-05       Impact factor: 6.118

2.  Safety and Accuracy of Factory-Calibrated Continuous Glucose Monitoring in Pediatric Patients Undergoing Hematopoietic Stem Cell Transplantation.

Authors:  Jenna Sopfe; Tim Vigers; Laura Pyle; Roger H Giller; Gregory P Forlenza
Journal:  Diabetes Technol Ther       Date:  2020-03-17       Impact factor: 6.118

3.  A Head-to-Head Comparison Study of the First-Day Performance of Two Factory-Calibrated CGM Systems.

Authors:  Douglas Denham
Journal:  J Diabetes Sci Technol       Date:  2020-01-08

4.  Factory-Calibrated Continuous Glucose Monitoring: How and Why It Works, and the Dangers of Reuse Beyond Approved Duration of Wear.

Authors:  Gregory P Forlenza; Taisa Kushner; Laurel H Messer; R Paul Wadwa; Sriram Sankaranarayanan
Journal:  Diabetes Technol Ther       Date:  2019-02-28       Impact factor: 6.118

5.  Accuracy of a 14-Day Factory-Calibrated Continuous Glucose Monitoring System With Advanced Algorithm in Pediatric and Adult Population With Diabetes.

Authors:  Shridhara Alva; Timothy Bailey; Ronald Brazg; Erwin S Budiman; Kristin Castorino; Mark P Christiansen; Gregory Forlenza; Mark Kipnes; David R Liljenquist; Hanqing Liu
Journal:  J Diabetes Sci Technol       Date:  2020-09-19

6.  Accuracy of a Factory-Calibrated, Real-Time Continuous Glucose Monitoring System During 10 Days of Use in Youth and Adults with Diabetes.

Authors:  R Paul Wadwa; Lori M Laffel; Viral N Shah; Satish K Garg
Journal:  Diabetes Technol Ther       Date:  2018-06-14       Impact factor: 6.118

7.  Comparison of Interstitial Fluid Glucose Levels Obtained by Continuous Glucose Monitoring and Flash Glucose Monitoring in Patients With Type 2 Diabetes Mellitus Undergoing Hemodialysis.

Authors:  Takahiro Yajima; Hiroshi Takahashi; Keigo Yasuda
Journal:  J Diabetes Sci Technol       Date:  2019-10-18

8.  Exercise improves metformin 72-h glucose control by reducing the frequency of hyperglycemic peaks.

Authors:  J F Ortega; F Morales-Palomo; M Ramirez-Jimenez; A Moreno-Cabañas; R Mora-Rodríguez
Journal:  Acta Diabetol       Date:  2020-02-04       Impact factor: 4.280

9.  The Effect of Various, Everyday Practices on Glucose Levels in Critically Ill Children.

Authors:  Eleni Tsotridou; Eirini Kotzapanagiotou; Asimina Violaki; Meropi Dimitriadou; Menelaos Svirkos; Peristera-Eleni Mantzafleri; Vasiliki Papadopoulou; Maria Sdougka; Athanasios Christoforidis
Journal:  J Diabetes Sci Technol       Date:  2020-10-07

Review 10.  Review of methods for detecting glycemic disorders.

Authors:  Michael Bergman; Muhammad Abdul-Ghani; Ralph A DeFronzo; Melania Manco; Giorgio Sesti; Teresa Vanessa Fiorentino; Antonio Ceriello; Mary Rhee; Lawrence S Phillips; Stephanie Chung; Celeste Cravalho; Ram Jagannathan; Louis Monnier; Claude Colette; David Owens; Cristina Bianchi; Stefano Del Prato; Mariana P Monteiro; João Sérgio Neves; Jose Luiz Medina; Maria Paula Macedo; Rogério Tavares Ribeiro; João Filipe Raposo; Brenda Dorcely; Nouran Ibrahim; Martin Buysschaert
Journal:  Diabetes Res Clin Pract       Date:  2020-06-01       Impact factor: 5.602

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.