Adequate image quality with reduced radiation dose in prospectively triggered coronary CTA compared with retrospective techniques.

Elisabeth Arnoldi1, Thorsten R Johnson, Carsten Rist, Bernd J Wintersperger, Wieland H Sommer, Alexander Becker, Christoph R Becker, Maximilian F Reiser, Konstantin Nikolaou.   

Abstract

The goal of our study was to compare a prospective triggering (PT) CT technique with retrospectively gated (RG) CT techniques in coronary computed tomographic angiograms (CCTA) with respect to image quality and radiation dose. Sixty consecutive patients were enrolled. CCTAs using the RG technique were obtained with a dual-source 64-slice CT system in 40 patients, using ECG-triggered tube current modulation, with either a broad pulsing window at 30-80% of the RR interval (group RGb, 20 patients, heart rate > 70 bpm) or a small pulsing window at 70% (group RGs, 20 patients, heart rate < 70 bpm). The other 20 patients underwent CCTA using the PT technique on a 128-slice CT system (group PT, heart rate < 70 bpm). All images were evaluated by two observers for quality on a three-point scale, with 1 being excellent and 3 being insufficient. The effective radiation dose was calculated for each patient. The average image quality score was 1.5 +/- 0.6 for PT, 1.35 +/- 0.5 for RGs and 1.65 +/- 0.5 for RGb. The mean effective dose for RGb was 9 +/- 4 mSv, for RGs 7 +/- 3 mSv and for PT 3 +/- 1 mSv. This represents a 57% dose reduction for PT compared with RGs and a 67% dose reduction for PT compared with RGb. In conclusion, in selected patients CCTA with the PT technique offers adequate image quality with a significantly lower radiation dose compared with CCTA using RG techniques.

Entities:  

Mesh:

Year:  2009        PMID: 19415293     DOI: 10.1007/s00330-009-1411-9

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  35 in total

1.  ACC/AHA guidelines for coronary angiography. A report of the American College of Cardiology/American Heart Association Task Force on practice guidelines (Committee on Coronary Angiography). Developed in collaboration with the Society for Cardiac Angiography and Interventions.

Authors:  P J Scanlon; D P Faxon; A M Audet; B Carabello; G J Dehmer; K A Eagle; R D Legako; D F Leon; J A Murray; S E Nissen; C J Pepine; R M Watson; J L Ritchie; R J Gibbons; M D Cheitlin; T J Gardner; A Garson; R O Russell; T J Ryan; S C Smith
Journal:  J Am Coll Cardiol       Date:  1999-05       Impact factor: 24.094

2.  Image quality, motion artifacts, and reconstruction timing of 64-slice coronary computed tomography angiography with 0.33-second rotation speed.

Authors:  Bernd J Wintersperger; Konstantin Nikolaou; Franz von Ziegler; Thorsten Johnson; Carsten Rist; Alexander Leber; Thomas Flohr; Andreas Knez; Maximilian F Reiser; Christoph R Becker
Journal:  Invest Radiol       Date:  2006-05       Impact factor: 6.016

Review 3.  Computed tomography--an increasing source of radiation exposure.

Authors:  David J Brenner; Eric J Hall
Journal:  N Engl J Med       Date:  2007-11-29       Impact factor: 91.245

4.  Image quality and reconstruction intervals of dual-source CT coronary angiography: recommendations for ECG-pulsing windowing.

Authors:  Sebastian Leschka; Hans Scheffel; Lotus Desbiolles; Andre Plass; Oliver Gaemperli; Ines Valenta; Lars Husmann; Thomas G Flohr; Michele Genoni; Borut Marincek; Philipp A Kaufmann; Hatem Alkadhi
Journal:  Invest Radiol       Date:  2007-08       Impact factor: 6.016

5.  Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose.

Authors:  James P Earls; Elise L Berman; Bruce A Urban; Charlene A Curry; Judith L Lane; Robert S Jennings; Colin C McCulloch; Jiang Hsieh; John H Londt
Journal:  Radiology       Date:  2008-01-14       Impact factor: 11.105

6.  Comparison of radiation doses from multislice computed tomography coronary angiography and conventional diagnostic angiography.

Authors:  Duncan R Coles; Mary A Smail; Ian S Negus; Peter Wilde; Martin Oberhoff; Karl R Karsch; Andreas Baumbach
Journal:  J Am Coll Cardiol       Date:  2006-04-19       Impact factor: 24.094

7.  Visual and automatic grading of coronary artery stenoses with 64-slice CT angiography in reference to invasive angiography.

Authors:  Stephanie Busch; Thorsten R C Johnson; Konstantin Nikolaou; Franz von Ziegler; Andreas Knez; Maximilian F Reiser; Christoph R Becker
Journal:  Eur Radiol       Date:  2006-12-16       Impact factor: 5.315

8.  Diagnostic accuracy of dual-source computed tomography in the diagnosis of coronary artery disease.

Authors:  Thorsten R C Johnson; Konstantin Nikolaou; Stephanie Busch; Alexander W Leber; Alexander Becker; Bernd J Wintersperger; Carsten Rist; Andreas Knez; Maximilian F Reiser; Christoph R Becker
Journal:  Invest Radiol       Date:  2007-10       Impact factor: 6.016

9.  Radiation dose of cardiac dual-source CT: the effect of tailoring the protocol to patient-specific parameters.

Authors:  Hatem Alkadhi; Paul Stolzmann; Hans Scheffel; Lotus Desbiolles; Stephan Baumüller; André Plass; Michele Genoni; Borut Marincek; Sebastian Leschka
Journal:  Eur J Radiol       Date:  2008-10-30       Impact factor: 3.528

10.  Radiation dose estimates from cardiac multislice computed tomography in daily practice: impact of different scanning protocols on effective dose estimates.

Authors:  Jörg Hausleiter; Tanja Meyer; Martin Hadamitzky; Ester Huber; Maria Zankl; Stefan Martinoff; Adnan Kastrati; Albert Schömig
Journal:  Circulation       Date:  2006-03-06       Impact factor: 29.690

View more
  24 in total

Review 1.  Diagnostic value of coronary CT angiography with prospective ECG-gating in the diagnosis of coronary artery disease: a systematic review and meta-analysis.

Authors:  Zhonghua Sun; Kwan-Hoong Ng
Journal:  Int J Cardiovasc Imaging       Date:  2012-01-04       Impact factor: 2.357

2.  Dual-step prospective ECG-triggered 128-slice dual-source CT for evaluation of coronary arteries and cardiac function without heart rate control: a technical note.

Authors:  Gudrun Feuchtner; Robert Goetti; Andrè Plass; Stephan Baumueller; Paul Stolzmann; Hans Scheffel; Monika Wieser; Borut Marincek; Hatem Alkadhi; Sebastian Leschka
Journal:  Eur Radiol       Date:  2010-04-21       Impact factor: 5.315

Review 3.  Paediatric cardiac computed tomography: a review of imaging techniques and radiation dose consideration.

Authors:  Carolyn Young; Andrew M Taylor; Catherine M Owens
Journal:  Eur Radiol       Date:  2010-12-28       Impact factor: 5.315

4.  [Cardiac SPECT/CT: correlation between atherosclerosis, significant coronary artery stenoses and myocardial perfusion parameters in patients with known coronary artery disease].

Authors:  C Ubleis; C Rist; I Griesshammer; A Becker; C Becker; M Hacker
Journal:  Radiologe       Date:  2010-04       Impact factor: 0.635

5.  Impact of iterative reconstruction on CT coronary calcium quantification.

Authors:  Akira Kurata; Anoeshka Dharampal; Admir Dedic; Pim J de Feyter; Gabriel P Krestin; Marcel L Dijkshoorn; Koen Nieman
Journal:  Eur Radiol       Date:  2013-09-22       Impact factor: 5.315

6.  Retrospective versus prospective ECG-gated dual-source CT in pediatric patients with congenital heart diseases: comparison of image quality and radiation dose.

Authors:  Kwang Nam Jin; Eun-Ah Park; Cheong-Il Shin; Whal Lee; Jin Wook Chung; Jae Hyung Park
Journal:  Int J Cardiovasc Imaging       Date:  2010-01-01       Impact factor: 2.357

7.  Systolic prospectively ECG-triggered dual-source CT angiography for evaluation of the coronary arteries in heart transplant recipients.

Authors:  Gorka Bastarrika; Jordi Broncano; María Arraiza; Pedro M Azcárate; Isabel Simon-Yarza; Beltrán G Levy Praschker; Jesús C Pueyo; José L Zubieta; Gregorio Rabago
Journal:  Eur Radiol       Date:  2011-04-12       Impact factor: 5.315

8.  Dose study of electrocardiogram automatic tube current modulation technology in prospective coronary computed tomography angiography scans of overweight patients.

Authors:  Guiru He; Xiaopei Liu; Yan Liu; Wei Wang; Zhiliang Ke
Journal:  Exp Ther Med       Date:  2015-04-07       Impact factor: 2.447

Review 9.  SCCT guidelines on radiation dose and dose-optimization strategies in cardiovascular CT.

Authors:  Sandra S Halliburton; Suhny Abbara; Marcus Y Chen; Ralph Gentry; Mahadevappa Mahesh; Gilbert L Raff; Leslee J Shaw; Jörg Hausleiter
Journal:  J Cardiovasc Comput Tomogr       Date:  2011 Jul-Aug

10.  Declining radiation dose of coronary computed tomography angiography: German cardiac CT registry experience 2009-2014.

Authors:  Axel Schmermund; Mohamed Marwan; Jörg Hausleiter; Sebastian Barth; Oliver Bruder; Sebastian Kerber; Grigorius Korosoglou; Alexander Leber; Werner Moshage; Stephen Schröder; Steffen Schneider; Jochen Senges; Stephan Achenbach
Journal:  Clin Res Cardiol       Date:  2017-07-19       Impact factor: 5.460

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.