Literature DB >> 16682310

Comparison of radiation doses from multislice computed tomography coronary angiography and conventional diagnostic angiography.

Duncan R Coles1, Mary A Smail, Ian S Negus, Peter Wilde, Martin Oberhoff, Karl R Karsch, Andreas Baumbach.   

Abstract

OBJECTIVES: The aim of this study was to quantify and compare effective doses from conventional angiography and multislice computed tomography (MSCT) coronary angiography using a 16-slice scanner.
BACKGROUND: Multislice computed tomography is now a viable modality for cardiac imaging. However, for any diagnostic use of ionizing radiation, the risk to the patient must be considered and justified.
METHODS: Multislice computed tomography angiography and conventional angiography were used to assess 180 patients with suspected coronary artery disease. Estimates of effective dose were derived from exposure data recorded for each patient examination. For each modality, a comparable calculation technique was used, based on Monte Carlo modeling of the standard Cristy phantom.
RESULTS: In a subset of 91 directly comparable patients the mean effective dose for MSCT coronary angiography was 14.7 mSv (SD 2.2) and that for conventional angiography was 5.6 mSv (SD 3.6). A significant difference in effective dose was seen between the two protocols.
CONCLUSIONS: The mean effective dose for MSCT coronary angiography was significantly higher than that for conventional angiography. As MSCT cardiac scanners become increasingly available, operators must be aware of the radiation dose and the factors that affect it.

Entities:  

Mesh:

Year:  2006        PMID: 16682310     DOI: 10.1016/j.jacc.2005.11.078

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  59 in total

1.  Individually adapted coronary 64-slice CT angiography based on precontrast attenuation values, using different kVp and tube current settings: evaluation of image quality.

Authors:  Jean-François Paul
Journal:  Int J Cardiovasc Imaging       Date:  2011-10-18       Impact factor: 2.357

2.  Quantification of radiation dose savings in cardiac computed tomography using prospectively triggered mode and ECG pulsing: a phantom study.

Authors:  Lukas Lehmkuhl; Dieter Gosch; H D Nagel; Patrick Stumpp; Thomas Kahn; Matthias Gutberlet
Journal:  Eur Radiol       Date:  2010-04-09       Impact factor: 5.315

3.  Measurement of carotid intima-media thickness and carotid plaque detection for cardiovascular risk assessment.

Authors:  Heather M Johnson; James H Stein
Journal:  J Nucl Cardiol       Date:  2011-02       Impact factor: 5.952

4.  Fourth annual Mario S. Verani, MD Memorial Lecture: noninvasive imaging in coronary artery disease: changing roles, changing players.

Authors:  Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2006-07       Impact factor: 5.952

Review 5.  Dual-source cardiac computed tomography: image quality and dose considerations.

Authors:  Stephan Achenbach; Katharina Anders; Willi A Kalender
Journal:  Eur Radiol       Date:  2008-02-26       Impact factor: 5.315

6.  Effect of kVp on image quality and accuracy in coronary CT angiography according to patient body size: a phantom study.

Authors:  Sang Min Lee; Whal Lee; Jin Wook Chung; Eun-Ah Park; Jae Hyung Park
Journal:  Int J Cardiovasc Imaging       Date:  2013-11-02       Impact factor: 2.357

Review 7.  Coronary CT angiography with low radiation dose.

Authors:  Lei Xu; Zhaoqi Zhang
Journal:  Int J Cardiovasc Imaging       Date:  2010-02       Impact factor: 2.357

8.  Cardiac spiral dual-source CT with high pitch: a feasibility study.

Authors:  Dirk Ertel; Michael M Lell; Frank Harig; Thomas Flohr; Bernhard Schmidt; Willi A Kalender
Journal:  Eur Radiol       Date:  2009-06-30       Impact factor: 5.315

Review 9.  Transitioning from 16-slice to 64-slice multidetector computed tomography for the assessment of coronary artery disease: are we really making progress?

Authors:  Razi Khan; Sapna Rawal; Mark J Eisenberg
Journal:  Can J Cardiol       Date:  2009-09       Impact factor: 5.223

Review 10.  Coronary CT angiography in emergency department patients with acute chest pain: triple rule-out protocol versus dedicated coronary CT angiography.

Authors:  Hwa Yeon Lee; Seung Min Yoo; Charles S White
Journal:  Int J Cardiovasc Imaging       Date:  2008-10-14       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.