Literature DB >> 19365696

Second-generation extensively porous-coated THA stems at minimum 10-year followup.

David W Hennessy1, John J Callaghan, Steve S Liu.   

Abstract

The relatively high prevalence of thigh pain and stress shielding associated with the AML porous-coated cementless femoral component led to the development of the Prodigy, a femoral component with more extensive porous-coating and a distal polished bullet tip with medial diaphyseal relief to potentially decrease the flexural rigidity. We prospectively evaluated a cohort of 100 consecutive cementless total hip arthroplasties performed using this device. The minimum followup was 10 years (mean, 11.4 years; range, 10-12 years). At 10-year followup, 69 of the 86 patients (82 hips) were living, 14 patients with 15 hips were deceased, and three patients with three hips were lost to followup. No hips required a stem revision. Two patients (two hips) complained of thigh pain. All hips were bone ingrown. Distal tip radiolucencies and osteolysis occurred in 13 hips (17%) and none, respectively. Twenty-one hips (28%) demonstrated moderate or severe stress shielding. Only further followup will determine if this could be a clinical problem or one with revision surgery. These results encourage the authors to continue using second-generation extensively coated stems in their primary total hip arthroplasty constructs.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19365696      PMCID: PMC2866944          DOI: 10.1007/s11999-009-0831-9

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  30 in total

1.  Hydroxyapatite coating improves 8- to 10-year performance of the link RS cementless femoral stem.

Authors:  Lars Palm; Sven-Arne Jacobsson; Ingemar Ivarsson
Journal:  J Arthroplasty       Date:  2002-02       Impact factor: 4.757

2.  Total hip arthroplasty using an uncemented femoral component with taper design: outcome at 10-year follow-up.

Authors:  M Schramm; F Keck; D Hohmann; R P Pitto
Journal:  Arch Orthop Trauma Surg       Date:  2000       Impact factor: 3.067

3.  A ten- to 15-year follow-up of the cementless spotorno stem.

Authors:  P R Aldinger; S J Breusch; M Lukoschek; H Mau; V Ewerbeck; M Thomsen
Journal:  J Bone Joint Surg Br       Date:  2003-03

4.  Thirteen year results of total hip arthroplasty using a tapered titanium femoral component inserted without cement in patients with type C bone.

Authors:  Richard D Reitman; Roger Emerson; Linda Higgins; William Head
Journal:  J Arthroplasty       Date:  2003-10       Impact factor: 4.757

5.  Cementless Spotorno tapered titanium stems: excellent 10-15-year survival in 141 young patients.

Authors:  Peter R Aldinger; Marc Thomsen; Hans Mau; Volker Ewerbeck; Steffen J Breusch
Journal:  Acta Orthop Scand       Date:  2003-06

6.  Cementless titanium tapered-wedge femoral stem: 10- to 15-year follow-up.

Authors:  Amanda D Marshall; Jeffrey G Mokris; Richard D Reitman; Alicia Dandar; David R Mauerhan
Journal:  J Arthroplasty       Date:  2004-08       Impact factor: 4.757

7.  Cementless total hip arthroplasty with a tapered, rectangular titanium stem and a threaded cup: a minimum ten-year follow-up.

Authors:  Alexander Grübl; Catharina Chiari; Martin Gruber; Alexandra Kaider; Florian Gottsauner-Wolf
Journal:  J Bone Joint Surg Am       Date:  2002-03       Impact factor: 5.284

8.  Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation.

Authors:  W H Harris
Journal:  J Bone Joint Surg Am       Date:  1969-06       Impact factor: 5.284

9.  Cementless Lord total hip arthroplasty: cup loosening common after minimum 10-year follow-up of 103 hips.

Authors:  T Kubo; S Inoue; T Maeda; Y Arai; K Hirakawa; Y Wu; H Suehara; T Ogura; Y Hirasawa
Journal:  Acta Orthop Scand       Date:  2001-12

10.  THA using an anatomic stem in patients with femoral head osteonecrosis.

Authors:  Yong-Chan Ha; Hee Joong Kim; Shin-Yoon Kim; Tae-Young Kim; Kyung-Hoi Koo
Journal:  Clin Orthop Relat Res       Date:  2008-03-08       Impact factor: 4.176

View more
  12 in total

1.  Surgical Approaches to OA Therapy: Osteotomy and Arthroplasty.

Authors:  John J Callaghan
Journal:  HSS J       Date:  2011-12-28

2.  Two- to 4-Year Followup of a Short Stem THA Construct: Excellent Fixation, Thigh Pain a Concern.

Authors:  Richard L Amendola; Devon D Goetz; Steve S Liu; John J Callaghan
Journal:  Clin Orthop Relat Res       Date:  2017-02       Impact factor: 4.176

3.  The effect of poly sterilization on wear, osteolysis and survivorship of a press-fit cup at 10-year followup.

Authors:  Charles A Engh; Cara C Powers; Henry Ho; Sarah E Beykirch-Padgett; Robert H Hopper; C Anderson Engh
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

4.  The Frank Stinchfield Award: the impact of socioeconomic factors on outcome after THA: a prospective, randomized study.

Authors:  R Allen Butler; Seth Rosenzweig; Leann Myers; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

5.  Ultrashort versus Conventional Anatomic Cementless Femoral Stems in the Same Patients Younger Than 55 Years.

Authors:  Young-Hoo Kim; Jang-Won Park; Jun-Shik Kim
Journal:  Clin Orthop Relat Res       Date:  2016-06-03       Impact factor: 4.176

6.  Fixation strength of taper connection at head-neck junction in retrieved carbon fiber-reinforced PEEK hip stems.

Authors:  Ichiro Nakahara; Masaki Takao; Shunichi Bandoh; Nobuhiko Sugano
Journal:  J Artif Organs       Date:  2014-09-05       Impact factor: 1.731

7.  Distal fixation stems for revision of total hip replacement.

Authors:  Fernando Lopreite; Leonel Perez Alamino; Harold Simesen de Bielke; German Garabano; Hernán Del Sel
Journal:  J Orthop       Date:  2021-02-21

8.  High 10-year survival rate with an anatomic cementless stem (SPS).

Authors:  Elhadi Sariali; Alexandre Mouttet; Philippe Mordasini; Yves Catonné
Journal:  Clin Orthop Relat Res       Date:  2012-03-09       Impact factor: 4.176

9.  Assessment of retention force and bone apposition in two differently coated femoral stems after 6 months of loading in a goat model.

Authors:  Knut Harboe; Nils R Gjerdet; Einar Sudmann; Kari Indrekvam; Kjetil Søreide
Journal:  J Orthop Surg Res       Date:  2014-08-16       Impact factor: 2.359

Review 10.  Implant Design in Cementless Hip Arthroplasty.

Authors:  Jung Taek Kim; Jeong Joon Yoo
Journal:  Hip Pelvis       Date:  2016-06-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.