Literature DB >> 11817872

Cementless Lord total hip arthroplasty: cup loosening common after minimum 10-year follow-up of 103 hips.

T Kubo1, S Inoue, T Maeda, Y Arai, K Hirakawa, Y Wu, H Suehara, T Ogura, Y Hirasawa.   

Abstract

We evaluated the clinical and radiographic results of 103 (88 patients) cementless Lord total hip arthroplasty after a mean follow-up period of 12.5 (10-16) years. 77 hips had arthrosis, 15 rheumatoid arthritis and 11 osteonecrosis. The preoperative mean Harris Hip Score improved from 47 (19-66) to 87 (62-99) at 5 years, but declined to 77 (56-97) at the final examination. The survivorship of the cup, using radiographically confirmed aseptic loosening as the end point, was 63% at 10 years and 45% at 15 years and the survivorship of the stem was 97% at 10 years and 96% at 15 years. The low figures of the cup may be due to insufficient contact between the smooth-surfaced threads of the cup and the acetabular bone. Thinner polyethylene, insufficient initial bone coverage, and larger femoral head diameter were significantly related to the occurrence of loosening. We can not recommend this smooth-surfaced threaded cup because of its high failure.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11817872     DOI: 10.1080/000164701317268996

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  5 in total

1.  Second-generation extensively porous-coated THA stems at minimum 10-year followup.

Authors:  David W Hennessy; John J Callaghan; Steve S Liu
Journal:  Clin Orthop Relat Res       Date:  2009-04-14       Impact factor: 4.176

2.  A long-term follow-up of 60 Lord total hip arthroplasties in rheumatic disease: a mean follow-up of 14 years.

Authors:  C C Lybäck; C O Lybäck; A Kyrö; H J Kautiainen; E A Belt
Journal:  Int Orthop       Date:  2006-05-12       Impact factor: 3.075

3.  Long-term results of the threaded Mecron cup in primary total hip arthroplasty : A 15-20-year follow-up study.

Authors:  Michael Clarius; Alexander W Jung; Marcus R Streit; Christian Merle; Patric Raiss; Peter R Aldinger
Journal:  Int Orthop       Date:  2009-07-24       Impact factor: 3.075

4.  Long-term results of the threaded Weill cup in primary total hip arthroplasty: a 15-20-year follow-up study.

Authors:  Michael Clarius; Alexander W Jung; Patric Raiss; Marcus R Streit; Christian Merle; Peter R Aldinger
Journal:  Int Orthop       Date:  2009-07-24       Impact factor: 3.075

5.  Stable fixation of a madreporic Lord femoral prosthesis at 31-year follow-up in a total hip arthroplasty: A case report.

Authors:  Fernando M Judas; Joana Fonseca Ferreira; Rui Freitas Dias; Francisco M Lucas
Journal:  Int J Surg Case Rep       Date:  2015-12-14
  5 in total