Literature DB >> 15284973

Cementless titanium tapered-wedge femoral stem: 10- to 15-year follow-up.

Amanda D Marshall1, Jeffrey G Mokris, Richard D Reitman, Alicia Dandar, David R Mauerhan.   

Abstract

This investigation is an ongoing clinical and radiographic analysis of a titanium tapered-wedge femoral component with a proximal plasma-spray porous coating. Integral femoral stems (Biomet, Warsaw, IN) were implanted in 200 hips in 186 patients. Nineteen patients died before 10-year follow-up, and 50 patients were lost to follow-up. The mean follow-up of the remaining 129 hips was 11.6 years. Harris Hip Scores improved from 58 to 93. Thigh pain was 2.3%. Radiographic analysis revealed adaptive distal remodeling in zones 2, 3, 5, 6, and 13, with no evidence of osteolysis below the level of the calcar and the greater trochanteric region. Only 2 femoral stems were revised: 1 with suspected fibrous fixation at 7 years postoperatively and another with a broken trunion at 10 years postoperatively. A tapered titanium femoral stem with circumferential plasma-spray porous coating provides excellent long-term fixation, durable clinical outcome, and protects against osteolysis below the level of the calcar and greater trochanter.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15284973     DOI: 10.1016/j.arth.2004.01.006

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  14 in total

1.  Second-generation extensively porous-coated THA stems at minimum 10-year followup.

Authors:  David W Hennessy; John J Callaghan; Steve S Liu
Journal:  Clin Orthop Relat Res       Date:  2009-04-14       Impact factor: 4.176

2.  Early equivalence of uncemented press-fit and Compress femoral fixation.

Authors:  German L Farfalli; Patrick J Boland; Carol D Morris; Edward A Athanasian; John H Healey
Journal:  Clin Orthop Relat Res       Date:  2009-06-10       Impact factor: 4.176

3.  Periprosthetic fractures may be more likely in cementless femoral stems with sharp edges.

Authors:  K Hu; X Zhang; J Zhu; C Wang; W Ji; X Bai
Journal:  Ir J Med Sci       Date:  2009-10-22       Impact factor: 1.568

4.  Early Post-operative Periprosthetic Femur Fracture in the Presence of a Non-cemented Tapered Wedge Femoral Stem.

Authors:  H John Cooper; José A Rodriguez
Journal:  HSS J       Date:  2010-04-02

Review 5.  Surgical treatment options in patients with impaired bone quality.

Authors:  Norman A Johanson; Jody Litrenta; Jay M Zampini; Frederic Kleinbart; Haviva M Goldman
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

6.  Densitometric evaluation of bone-prosthetic counterface in hip and knee arthroplasty with modern implants.

Authors:  Andrea Cozzi Lepri; Marco Giorgini; Carla Signorini; Christian Carulli; Roberto Civinini; Maria Luisa Brandi; Massimo Innocenti
Journal:  Clin Cases Miner Bone Metab       Date:  2016-10-05

7.  A short tapered stem reduces intraoperative complications in primary total hip arthroplasty.

Authors:  Ryan G Molli; Adolph V Lombardi; Keith R Berend; Joanne B Adams; Michael A Sneller
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

8.  Cementless total hip arthroplasty for primary osteoarthritis in patients aged 55 years and older.

Authors:  Keijo T Mäkelä; Antti Eskelinen; Pekka Paavolainen; Pekka Pulkkinen; Ville Remes
Journal:  Acta Orthop       Date:  2010-02       Impact factor: 3.717

9.  The Bimetric cementless total hip replacement: 7-18 year follow-up assessing the influence of acetabular design on survivorship.

Authors:  R C Russell; A Ghassemi; J H Dorrell; D P Powles
Journal:  Int Orthop       Date:  2008-06-13       Impact factor: 3.075

10.  Comparison of short-stem with conventional-stem prostheses in total hip arthroplasty: an 8-year follow-up study.

Authors:  Alexander Zimmerer; Stefanie Slouka; Stefan Kinkel; Thomas Fritz; Stefan Weiss; Christian Sobau; Wolfgang Miehlke
Journal:  Arch Orthop Trauma Surg       Date:  2020-06-22       Impact factor: 2.928

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.