Literature DB >> 11886913

Cementless total hip arthroplasty with a tapered, rectangular titanium stem and a threaded cup: a minimum ten-year follow-up.

Alexander Grübl1, Catharina Chiari, Martin Gruber, Alexandra Kaider, Florian Gottsauner-Wolf.   

Abstract

BACKGROUND: We report the results of cementless total hip arthroplasty with a tapered, rectangular titanium stem that was introduced in 1979 and continues to be used today with only minor changes. The aim of the design is to achieve primary stability to resist rotational and axial forces through precision rasping and press-fit implantation of a tapered, rectangular femoral component.
METHODS: Between October 1986 and November 1987, 208 total hip arthroplasties with insertion of a tapered, rectangular titanium stem and a threaded cup without cement were performed in 200 consecutive patients (average age, sixty-one years; range, twenty-two to eighty-four years).
RESULTS: At the time of the latest follow-up, fifty-one patients (fifty-two hips) had died and sixteen patients had been lost to follow-up, leaving 133 patients. Twelve hips had been revised, two in patients who subsequently died, leaving 123 living patients without revision. The median follow-up time was 120.7 months. Five cups needed revision surgery because of aseptic loosening; two, because of massive polyethylene wear; one, because of posttraumatic migration; and one, because of breakage. Three femoral stems were revised: one because of malpositioning (the reoperation was done five days after implantation); one, because of infection; and the third, after multiple failed acetabular revisions. The mean Harris hip score for the patients who did not have revision was 85.4 points (range, 46 to 100 points) at the time of the latest follow-up. Four patients (3%) complained of thigh pain that was not associated with another disorder. According to the criteria of Engh et al., all femoral implants were graded as stable bone-ingrown. The probability of survival of both the femoral and the acetabular component at ten years, with any revision as the end point, was 0.92 (95% confidence interval, 0.88 to 0.97). The probability of survival of the cup was 0.93 (95% confidence interval, 0.89 to 0.97), and that of the stem was 0.99 (95% confidence interval, 0.97 to 1.00).
CONCLUSIONS: The results of arthroplasty with a tapered, rectangular titanium stem combined with a conical threaded cup inserted without cement were excellent at a minimum of ten years. Our data suggest that femoral stem fixation continues to be secure, while the threaded cup is prone to aseptic loosening.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11886913     DOI: 10.2106/00004623-200203000-00014

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  37 in total

1.  [Proposal for the classification of the periprosthetic membrane from loosened hip and knee endoprostheses].

Authors:  L Morawietz; Th Gehrke; R-A Classen; B Barden; M Otto; T Hansen; Th Aigner; P Stiehl; J Neidel; J H Schröder; L Frommelt; Th Schubert; C Meyer-Scholten; A König; Ph Ströbel; Ch P Rader; S Kirschner; F Lintner; W Rüther; A Skwara; I Bos; J Kriegsmann; V Krenn
Journal:  Pathologe       Date:  2004-09       Impact factor: 1.011

2.  Long-term follow-up of primary total hip arthroplasty with the Alloclassic Variall system.

Authors:  Josef Hochreiter; Giovanni Brusaferri; Klaus Kirschbichler; Katja Emmanuel
Journal:  Int Orthop       Date:  2015-08-18       Impact factor: 3.075

3.  [Cementless stems of the hip. Current status].

Authors:  H Effenberger; M Imhof; U Witzel; S Rehart
Journal:  Orthopade       Date:  2005-05       Impact factor: 1.087

4.  Modes of failure of a threaded acetabular cup : a radiographic study with EBRA of 42 revised cups.

Authors:  Thomas Ilchmann; Severin Neher; Franz Maurer; Kuno Weise
Journal:  Int Orthop       Date:  2006-06-08       Impact factor: 3.075

5.  Fifteen- to 20-year results of uncemented tapered fully porous-coated cobalt-chrome stems.

Authors:  Taek Rim Yoon; Sung-Man Rowe; Myung-Sun Kim; Sang-Gwon Cho; Jong-Keun Seon
Journal:  Int Orthop       Date:  2007-02-24       Impact factor: 3.075

6.  Three-dimensional stress analysis of threaded cups - a finite element analysis.

Authors:  U Witzel; W Rieger; H Effenberger
Journal:  Int Orthop       Date:  2007-02-21       Impact factor: 3.075

7.  Minimally invasive total hip replacement via the anterolateral approach in the supine position.

Authors:  G Pflüger; S Junk-Jantsch; V Schöll
Journal:  Int Orthop       Date:  2007-08       Impact factor: 3.075

Review 8.  [Histopathologic diagnostics in endoprosthetics: periprosthetic neosynovialitis, hypersensitivity reaction, and arthrofibrosis].

Authors:  V Krenn; M Otto; L Morawietz; T Hopf; M Jakobs; W Klauser; B Schwantes; T Gehrke
Journal:  Orthopade       Date:  2009-06       Impact factor: 1.087

9.  Second-generation extensively porous-coated THA stems at minimum 10-year followup.

Authors:  David W Hennessy; John J Callaghan; Steve S Liu
Journal:  Clin Orthop Relat Res       Date:  2009-04-14       Impact factor: 4.176

10.  Radiostereometric analysis: the hip.

Authors:  F Bottner; E Su; B Nestor; B Azzis; T P Sculco; M Bostrom
Journal:  HSS J       Date:  2005-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.