Literature DB >> 14560420

Thirteen year results of total hip arthroplasty using a tapered titanium femoral component inserted without cement in patients with type C bone.

Richard D Reitman1, Roger Emerson, Linda Higgins, William Head.   

Abstract

Although cementless arthroplasty with a tapered titanium femoral component has proven reliable in young patients with excellent bone quality, studies involving patients with poor bone quality are lacking. The present study evaluates the results of total hip arthroplasty (THA) using such a femoral component in patients with Type C femoral bone. Ninety-two THAs were performed in 81 patients aged 65 years and older using a tapered titanium cementless femoral component. Follow-up in 62 patients (72 hips) averaged 13.2 years (minimum, 10 years); 19 patients were lost to follow-up. According to Door's criteria, 20 femora were classified as Type A, 19 as Type B, and 33 as Type C. No stem was revised because of stem instability, thigh pain, or osteolysis. One stem was removed because of sepsis. Six acetabula were revised because of polyethylene wear and periacetabular osteolysis. Four patients reported mild thigh pain. Radiologic signs of osseous integration for cylindrical extensively porous coated cobalt-chrome femoral components are not valid for tapered titanium designs.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 14560420     DOI: 10.1016/s0883-5403(03)00344-9

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  15 in total

1.  Second-generation extensively porous-coated THA stems at minimum 10-year followup.

Authors:  David W Hennessy; John J Callaghan; Steve S Liu
Journal:  Clin Orthop Relat Res       Date:  2009-04-14       Impact factor: 4.176

2.  Survivorship of 2000 tapered titanium porous plasma-sprayed femoral components.

Authors:  Adolph V Lombardi; Keith R Berend; Thomas H Mallory; Michael D Skeels; Joanne B Adams
Journal:  Clin Orthop Relat Res       Date:  2008-10-31       Impact factor: 4.176

3.  A short tapered stem reduces intraoperative complications in primary total hip arthroplasty.

Authors:  Ryan G Molli; Adolph V Lombardi; Keith R Berend; Joanne B Adams; Michael A Sneller
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

4.  Early perioperative complication rates and subsidence with the Tribute® short cementless, tapered stem in primary total hip arthroplasty.

Authors:  John Attenello; Sean Chan; Kelvin Naito; Michele Saruwatari; Sean Saito; Samantha Andrews; Cass Nakasone
Journal:  J Orthop       Date:  2019-01-17

5.  Engineering endochondral bone: in vitro studies.

Authors:  Serafim M Oliveira; Isabel F Amaral; Mário A Barbosa; Cristina C Teixeira
Journal:  Tissue Eng Part A       Date:  2009-03       Impact factor: 3.845

6.  Classifications in Brief: The Dorr Classification of Femoral Bone.

Authors:  Jacob Wilkerson; Navin D Fernando
Journal:  Clin Orthop Relat Res       Date:  2020-05-06       Impact factor: 4.755

7.  Subsidence in Collarless Corail Hip Replacement.

Authors:  Veenesh Selvaratnam; Vishwanath Shetty; Vishal Sahni
Journal:  Open Orthop J       Date:  2015-05-29

8.  Minimal stress shielding with a Mallory-Head titanium femoral stem with proximal porous coating in total hip arthroplasty.

Authors:  Brad Ellison; Nicholas A Cheney; Keith R Berend; Adolph V Lombardi; Thomas H Mallory
Journal:  J Orthop Surg Res       Date:  2009-12-09       Impact factor: 2.359

9.  Evaluation of the results from proximal fixation of uncemented conical femoral components in Dorr type C femurs.

Authors:  Munif Ahmad Hatem; Bernardo Ferreira da Luz; Rodrigo Nishimoto Nishi; Paulo Gilberto Cimbalista de Alencar
Journal:  Rev Bras Ortop       Date:  2014-03-14

10.  Comparison of total hip arthroplasty in osteoarthritis of mechanical and rheumatologic causes.

Authors:  Leandro Ejnisman; Nathalia Zalc Leonhardt; Laura Fillipini Lorimier Fernandes; Marcos de Camargo Leonhardt; José Ricardo Negreiros Vicente; Alberto Tesconi Croci
Journal:  Acta Ortop Bras       Date:  2014       Impact factor: 0.513

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.