Literature DB >> 25190272

Fixation strength of taper connection at head-neck junction in retrieved carbon fiber-reinforced PEEK hip stems.

Ichiro Nakahara1, Masaki Takao, Shunichi Bandoh, Nobuhiko Sugano.   

Abstract

Carbon fiber-reinforced polyetheretherketone (CFR-PEEK) hip prostheses possess numerous advantages over metal prostheses; however, the security of the taper connection between the CFR-PEEK stem and the modular femoral head in vivo has not been verified. Therefore, we mechanically examined the taper connection of retrieved in vivo loaded CFR-PEEK stems in comparison with in vivo loaded titanium alloy stems. CFR-PEEK and titanium alloy femoral stems with a 12/14 taper trunnion were implanted in ovine hips. A 22-mm ceramic head was intraoperatively impacted to the stem. Retrieved specimens were obtained following weight-bearing conditions for up to 39 postoperative weeks and taper junction pull-off tests were conducted. Postoperative retrieved CFR-PEEK stem pull-off strength was significantly greater than that at time zero. Postoperative retrieved CFR-PEEK stem pull-off strength was also significantly higher than that of postoperative retrieved titanium alloy stem. Microscopic findings of the taper surface revealed no obvious damage in the retrieved CFR-PEEK stems, whereas fretting and corrosion were observed in the retrieved titanium alloy stems. The present findings suggest that the taper connection between the ceramic head and the 12/14 CFR-PEEK stem trunnion is more secure than that between the ceramic head and the titanium alloy trunnion.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25190272     DOI: 10.1007/s10047-014-0789-6

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  33 in total

1.  A multicenter retrieval study of the taper interfaces of modular hip prostheses.

Authors:  Jay R Goldberg; Jeremy L Gilbert; Joshua J Jacobs; Thomas W Bauer; Wayne Paprosky; Sue Leurgans
Journal:  Clin Orthop Relat Res       Date:  2002-08       Impact factor: 4.176

2.  Influence of assembly procedure and material combination on the strength of the taper connection at the head-neck junction of modular hip endoprostheses.

Authors:  Annelie Rehmer; Nicholas E Bishop; Michael M Morlock
Journal:  Clin Biomech (Bristol, Avon)       Date:  2011-09-08       Impact factor: 2.063

3.  Composite hip prosthesis design. I. Analysis.

Authors:  H Yildiz; S K Ha; F K Chang
Journal:  J Biomed Mater Res       Date:  1998-01

4.  Composite technology for total hip arthroplasty.

Authors:  H B Skinner
Journal:  Clin Orthop Relat Res       Date:  1988-10       Impact factor: 4.176

5.  The tradeoffs associated with modular hip prostheses.

Authors:  J P Collier; M B Mayor; I R Williams; V A Surprenant; H P Surprenant; B H Currier
Journal:  Clin Orthop Relat Res       Date:  1995-02       Impact factor: 4.176

6.  An analysis of the head-neck taper interface in retrieved hip prostheses.

Authors:  J R Lieberman; C M Rimnac; K L Garvin; R W Klein; E A Salvati
Journal:  Clin Orthop Relat Res       Date:  1994-03       Impact factor: 4.176

7.  Detection of orthopaedic implants in vivo by enhanced-sensitivity, walk-through metal detectors.

Authors:  Miguel A Ramirez; Edward K Rodriguez; David Zurakowski; Lars C Richardson
Journal:  J Bone Joint Surg Am       Date:  2007-04       Impact factor: 5.284

8.  Pseudotumours associated with metal-on-metal hip resurfacings.

Authors:  H Pandit; S Glyn-Jones; P McLardy-Smith; R Gundle; D Whitwell; C L M Gibbons; S Ostlere; N Athanasou; H S Gill; D W Murray
Journal:  J Bone Joint Surg Br       Date:  2008-07

9.  In vitro biocompatibility of polyetheretherketone and polysulfone composites.

Authors:  L M Wenz; K Merritt; S A Brown; A Moet; A D Steffee
Journal:  J Biomed Mater Res       Date:  1990-02

10.  Long-term compressive property durability of carbon fibre-reinforced polyetheretherketone composite in physiological saline.

Authors:  G Zhang; R A Latour; J M Kennedy; H Del Schutte; R J Friedman
Journal:  Biomaterials       Date:  1996-04       Impact factor: 12.479

View more
  1 in total

1.  Journal of Artificial Organs 2014: the year in review.

Authors:  Y Sawa; K Matsuda; E Tatsumi; G Matsumiya; T Abe; K Fukunaga; A Kishida; K Kokubo; T Masuzawa; A Myoui; M Nishimura; T Nishimura; T Nishinaka; E Okamoto; S Tokunaga; T Tomo; T Tsukiya; Y Yagi; T Yamaoka
Journal:  J Artif Organs       Date:  2015-02-21       Impact factor: 1.731

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.