Literature DB >> 19336276

B1 homogenization in MRI by multilayer coupled coils.

Shumin Wang1, Joseph Murphy-Boesch, Hellmut Merkle, Alan P Koretsky, Jeff H Duyn.   

Abstract

Transmit B(1)(+) field homogenization in high-field ( > 3.0 T) human magnetic resonance imaging (MRI) is challenging due to radio-frequency wavelength effects. An approach based on appropriately coupling surface coils to a volume coil was investigated. Electromagnetic simulation results demonstrated the feasibility and effectiveness of this method in proton MRI of the human head at 7.0 T.

Entities:  

Mesh:

Year:  2009        PMID: 19336276      PMCID: PMC3197805          DOI: 10.1109/TMI.2008.2006523

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  10 in total

1.  A hybrid inverse approach applied to the design of lumped-element RF coils.

Authors:  H Fujita; L S Petropoulos; M A Morich; S M Shvartsman; R W Brown
Journal:  IEEE Trans Biomed Eng       Date:  1999-03       Impact factor: 4.538

2.  Effect of RF coil excitation on field inhomogeneity at ultra high fields: a field optimized TEM resonator.

Authors:  T S Ibrahim; R Lee; B A Baertlein; A M Abduljalil; H Zhu; P M Robitaille
Journal:  Magn Reson Imaging       Date:  2001-12       Impact factor: 2.546

3.  A time-harmonic inverse methodology for the design of RF coils in MRI.

Authors:  Ben G Lawrence; Stuart Crozier; Desmond D Yau; David M Doddrell
Journal:  IEEE Trans Biomed Eng       Date:  2002-01       Impact factor: 4.538

4.  Transmit SENSE.

Authors:  Ulrich Katscher; Peter Börnert; Christoph Leussler; Johan S van den Brink
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

5.  Focused, eight-element transceive phased array coil for parallel magnetic resonance imaging of the chest--theoretical considerations.

Authors:  Bing Keong Li; Feng Liu; Stuart Crozier
Journal:  Magn Reson Med       Date:  2005-06       Impact factor: 4.668

6.  Manipulation of image intensity distribution at 7.0 T: passive RF shimming and focusing with dielectric materials.

Authors:  Qing X Yang; Weihua Mao; Jinghua Wang; Michael B Smith; Hao Lei; Xiaoliang Zhang; Kamil Ugurbil; Wei Chen
Journal:  J Magn Reson Imaging       Date:  2006-07       Impact factor: 4.813

7.  Analysing radio-frequency coil arrays in high-field magnetic resonance imaging by the combined field integral equation method.

Authors:  Shumin Wang; Jeff H Duyn
Journal:  Phys Med Biol       Date:  2006-06-06       Impact factor: 3.609

8.  9.4T human MRI: preliminary results.

Authors:  Thomas Vaughan; Lance DelaBarre; Carl Snyder; Jinfeng Tian; Can Akgun; Devashish Shrivastava; Wanzahn Liu; Chris Olson; Gregor Adriany; John Strupp; Peter Andersen; Anand Gopinath; Pierre-Francois van de Moortele; Michael Garwood; Kamil Ugurbil
Journal:  Magn Reson Med       Date:  2006-12       Impact factor: 4.668

9.  Reduction of transmitter B1 inhomogeneity with transmit SENSE slice-select pulses.

Authors:  Zhenghui Zhang; Chun-Yu Yip; William Grissom; Douglas C Noll; Fernando E Boada; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2007-05       Impact factor: 4.668

10.  On the field inhomogeneity of a birdcage coil.

Authors:  J Jin; G Shen; T Perkins
Journal:  Magn Reson Med       Date:  1994-09       Impact factor: 4.668

  10 in total
  6 in total

1.  Transmit B1-field correction at 7 T using actively tuned coupled inner elements.

Authors:  Hellmut Merkle; Joseph Murphy-Boesch; Peter van Gelderen; Shumin Wang; Tie-Qiang Li; Alan P Koretsky; Josef H Duyn
Journal:  Magn Reson Med       Date:  2011-03-24       Impact factor: 4.668

2.  Field shaping arrays: a means to address shading in high field breast MRI.

Authors:  Ileana Hancu; Seung-Kyun Lee; W Thomas Dixon; Laura Sacolick; Ricardo Becerra; Zhenghui Zhang; Graeme McKinnon; Vijayanand Alagappan
Journal:  J Magn Reson Imaging       Date:  2012-06-21       Impact factor: 4.813

3.  Radiofrequency pulse designs for three-dimensional MRI providing uniform tipping in inhomogeneous B₁ fields.

Authors:  Hui Liu; Gerald B Matson
Journal:  Magn Reson Med       Date:  2011-04-26       Impact factor: 4.668

4.  A method to localize RF B₁ field in high-field magnetic resonance imaging systems.

Authors:  Hyoungsuk Yoo; Anand Gopinath; J Thomas Vaughan
Journal:  IEEE Trans Biomed Eng       Date:  2012-08-23       Impact factor: 4.538

5.  A radially interleaved sodium and proton coil array for brain MRI at 7 T.

Authors:  Bili Wang; Bei Zhang; Zidan Yu; Carlotta Ianniello; Karthik Lakshmanan; Jan Paska; Guillaume Madelin; Martijn Cloos; Ryan Brown
Journal:  NMR Biomed       Date:  2021-09-03       Impact factor: 4.478

6.  Improvement of magnetic resonance imaging using a wireless radiofrequency resonator array.

Authors:  Akbar Alipour; Alan C Seifert; Bradley N Delman; Philip M Robson; Raj Shrivastava; Patrick R Hof; Gregor Adriany; Zahi A Fayad; Priti Balchandani
Journal:  Sci Rep       Date:  2021-11-29       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.