Literature DB >> 22929360

A method to localize RF B₁ field in high-field magnetic resonance imaging systems.

Hyoungsuk Yoo1, Anand Gopinath, J Thomas Vaughan.   

Abstract

In high-field magnetic resonance imaging (MRI) systems, B₀ fields of 7 and 9.4 T, the RF field shows greater inhomogeneity compared to clinical MRI systems with B₀ fields of 1.5 and 3.0 T. In multichannel RF coils, the magnitude and phase of the input to each coil element can be controlled independently to reduce the nonuniformity of the RF field. The convex optimization technique has been used to obtain the optimum excitation parameters with iterative solutions for homogeneity in a selected region of interest. The pseudoinverse method has also been used to find a solution. The simulation results for 9.4- and 7-T MRI systems are discussed in detail for the head model. Variation of the simulation results in a 9.4-T system with the number of RF coil elements for different positions of the regions of interest in a spherical phantom are also discussed. Experimental results were obtained in a phantom in the 9.4-T system and are compared to the simulation results and the specific absorption rate has been evaluated.

Entities:  

Mesh:

Year:  2012        PMID: 22929360      PMCID: PMC4041104          DOI: 10.1109/TBME.2012.2208965

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  15 in total

1.  Signal-to-noise ratio and absorbed power as functions of main magnetic field strength, and definition of "90 degrees " RF pulse for the head in the birdcage coil.

Authors:  C M Collins; M B Smith
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

2.  Effect of RF coil excitation on field inhomogeneity at ultra high fields: a field optimized TEM resonator.

Authors:  T S Ibrahim; R Lee; B A Baertlein; A M Abduljalil; H Zhu; P M Robitaille
Journal:  Magn Reson Imaging       Date:  2001-12       Impact factor: 2.546

3.  Different excitation and reception distributions with a single-loop transmit-receive surface coil near a head-sized spherical phantom at 300 MHz.

Authors:  C M Collins; Q X Yang; J H Wang; X Zhang; H Liu; S Michaeli; X-H Zhu; G Adriany; J T Vaughan; P Anderson; H Merkle; K Ugurbil; M B Smith; W Chen
Journal:  Magn Reson Med       Date:  2002-05       Impact factor: 4.668

4.  B1 mapping by Bloch-Siegert shift.

Authors:  Laura I Sacolick; Florian Wiesinger; Ileana Hancu; Mika W Vogel
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

5.  B(1) destructive interferences and spatial phase patterns at 7 T with a head transceiver array coil.

Authors:  Pierre-François Van de Moortele; Can Akgun; Gregor Adriany; Steen Moeller; Johannes Ritter; Christopher M Collins; Michael B Smith; J Thomas Vaughan; Kāmil Uğurbil
Journal:  Magn Reson Med       Date:  2005-12       Impact factor: 4.668

6.  Focused, eight-element transceive phased array coil for parallel magnetic resonance imaging of the chest--theoretical considerations.

Authors:  Bing Keong Li; Feng Liu; Stuart Crozier
Journal:  Magn Reson Med       Date:  2005-06       Impact factor: 4.668

7.  Electromagnetic perspective on the operation of RF coils at 1.5-11.7 Tesla.

Authors:  Tamer S Ibrahim; Chad Mitchell; Petra Schmalbrock; Robert Lee; Donald W Chakeres
Journal:  Magn Reson Med       Date:  2005-09       Impact factor: 4.668

8.  Proposed radiofrequency phased-array excitation scheme for homogenous and localized 7-Tesla whole-body imaging based on full-wave numerical simulations.

Authors:  Roney Abraham; Tamer S Ibrahim
Journal:  Magn Reson Med       Date:  2007-02       Impact factor: 4.668

9.  Exploring the limits of RF shimming for high-field MRI of the human head.

Authors:  Weihua Mao; Michael B Smith; Christopher M Collins
Journal:  Magn Reson Med       Date:  2006-10       Impact factor: 4.668

10.  9.4T human MRI: preliminary results.

Authors:  Thomas Vaughan; Lance DelaBarre; Carl Snyder; Jinfeng Tian; Can Akgun; Devashish Shrivastava; Wanzahn Liu; Chris Olson; Gregor Adriany; John Strupp; Peter Andersen; Anand Gopinath; Pierre-Francois van de Moortele; Michael Garwood; Kamil Ugurbil
Journal:  Magn Reson Med       Date:  2006-12       Impact factor: 4.668

View more
  3 in total

1.  Rapid slice excitation without B0 gradients using large array coils.

Authors:  Ke Feng; Steven M Wright
Journal:  Quant Imaging Med Surg       Date:  2014-04

2.  Improvement of Electromagnetic Field Distributions Using High Dielectric Constant (HDC) Materials for CTL-Spine MRI: Numerical Simulations and Experiments.

Authors:  Bu S Park; Brent McCright; Leonardo M Angelone; Amir Razjouyan; Sunder S Rajan
Journal:  IEEE Trans Electromagn Compat       Date:  2017-10       Impact factor: 2.006

Review 3.  Parallel transmission for ultrahigh-field imaging.

Authors:  Francesco Padormo; Arian Beqiri; Joseph V Hajnal; Shaihan J Malik
Journal:  NMR Biomed       Date:  2015-05-19       Impact factor: 4.044

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.