Literature DB >> 19175116

Implications of resolution and noise for in vivo micro-MRI of trabecular bone.

Charles Q Li1, Jeremy F Magland, Chamith S Rajapakse, X Edward Guo, X Henry Zhang, Branimir Vasilic, Felix W Wehrli.   

Abstract

Osteoporotic bone loss is accompanied by impaired structural integrity of the trabecular network, leading to a decrease in the overall mechanical properties of the bone. The development of the "virtual bone biopsy" (VBB), a method combining magnetic resonance microimaging (microMRI) and digital image processing techniques, has previously been shown to quantify topology and scale of human trabecular bone noninvasively. The aim of this work was to determine the extent to which structural parameters derived from images acquired in the limited spatial resolution regime of in vivo imaging are sensitive to resolution and noise and further, whether under these conditions, a small amount of bone loss and its associated structural manifestations can be detected. Toward these goals 3D models of trabecular bone representing multiple anatomic locations were generated on the basis of microCT images of human cadaveric bone cores. These images were binarized and the resulting data arrays representing pure bone (proton density=0) and pure marrow (proton density=255) subjected to simulated MR imaging by Cartesian sampling of k space, yielding, after 3D Fourier reconstruction, voxel sizes currently achievable in vivo. Subsequently, realistic levels of Gaussian noise were superimposed on the complex data and magnitude images were computed. The resulting images were subsequently VBB processed for a range of signal-to-noise ratio (SNR) values and image voxel sizes. For comparison of the predicted behavior to in vivo data, images from a recent patient study were evaluated as well. Systematic changes of the derived structural parameters changing progressively with decreasing SNR were noted, and it is shown that the errors are correctable using simple linear transformations, thereby allowing the data to be normalized. The predicted dependence of the structural parameters on SNR also closely parallel those observed in vivo. Finally, in order to assess the sensitivity of the VBB processing algorithms to detect bone loss during disease progression or regression in response to treatment, the high-resolution specimen data were subjected to 5% bone loss either by homogeneous or heterogeneous erosion and microMR images simulated at in vivo resolution and SNR. At typical in vivo SNR (SNR=12) and effective image resolution (160 microm isotropic and 137 x 137 X 410 microm3), VBB algorithms were able to detect the structural implications of a 5% loss in bone volume fraction with high statistical significance.

Entities:  

Mesh:

Year:  2008        PMID: 19175116      PMCID: PMC2673605          DOI: 10.1118/1.3005598

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  43 in total

1.  Mechanical consequences of bone loss in cancellous bone.

Authors:  J C van der Linden; J Homminga; J A Verhaar; H Weinans
Journal:  J Bone Miner Res       Date:  2001-03       Impact factor: 6.741

Review 2.  Bone microstructure in osteoporosis: transilial biopsy and histomorphometry.

Authors:  M Janet Barger-Lux; Robert R Recker
Journal:  Top Magn Reson Imaging       Date:  2002-10

3.  Trabecular bone pattern factor--a new parameter for simple quantification of bone microarchitecture.

Authors:  M Hahn; M Vogel; M Pompesius-Kempa; G Delling
Journal:  Bone       Date:  1992       Impact factor: 4.398

4.  A novel local thresholding algorithm for trabecular bone volume fraction mapping in the limited spatial resolution regime of in vivo MRI.

Authors:  Branimir Vasilic; Felix W Wehrli
Journal:  IEEE Trans Med Imaging       Date:  2005-12       Impact factor: 10.048

Review 5.  Trabecular bone architecture in the pathogenesis and prevention of fracture.

Authors:  A M Parfitt
Journal:  Am J Med       Date:  1987-01-26       Impact factor: 4.965

6.  Star volume of marrow space and trabeculae in iliac crest: sampling procedure and correlation to star volume of first lumbar vertebra.

Authors:  A Vesterby
Journal:  Bone       Date:  1990       Impact factor: 4.398

7.  Effects of salmon calcitonin on trabecular microarchitecture as determined by magnetic resonance imaging: results from the QUEST study.

Authors:  Charles H Chesnut; Sharmilla Majumdar; David C Newitt; Andrew Shields; Jan Van Pelt; Ellen Laschansky; Moise Azria; Audrey Kriegman; Melvin Olson; Erik F Eriksen; Linda Mindeholm
Journal:  J Bone Miner Res       Date:  2005-04-27       Impact factor: 6.741

8.  Bone structure of the distal radius and the calcaneus vs BMD of the spine and proximal femur in the prediction of osteoporotic spine fractures.

Authors:  Thomas M Link; Volker Vieth; Julia Matheis; David Newitt; Ying Lu; Ernst J Rummeny; Sharmila Majumdar
Journal:  Eur Radiol       Date:  2001-10-05       Impact factor: 5.315

9.  Trabecular structure quantified with the MRI-based virtual bone biopsy in postmenopausal women contributes to vertebral deformity burden independent of areal vertebral BMD.

Authors:  Glenn A Ladinsky; Branimir Vasilic; Andra M Popescu; Michael Wald; Babette S Zemel; Peter J Snyder; Louise Loh; Hee Kwon Song; Punam K Saha; Alexander C Wright; Felix W Wehrli
Journal:  J Bone Miner Res       Date:  2008-01       Impact factor: 6.741

10.  Trabecular bone structure analysis in the limited spatial resolution regime of in vivo MRI.

Authors:  Jeremy F Magland; Felix W Wehrli
Journal:  Acad Radiol       Date:  2008-12       Impact factor: 3.173

View more
  10 in total

1.  Performance of μMRI-Based virtual bone biopsy for structural and mechanical analysis at the distal tibia at 7T field strength.

Authors:  Yusuf A Bhagat; Chamith S Rajapakse; Jeremy F Magland; James H Love; Alexander C Wright; Michael J Wald; Hee Kwon Song; Felix W Wehrli
Journal:  J Magn Reson Imaging       Date:  2011-02       Impact factor: 4.813

2.  Radiological diagnostic progress in skeletal diseases.

Authors:  Giuseppe Guglielmi; Michelangelo Nasuto; Michele La Porta
Journal:  Clin Cases Miner Bone Metab       Date:  2011-01

3.  Structural and mechanical parameters of trabecular bone estimated from in vivo high-resolution magnetic resonance images at 3 tesla field strength.

Authors:  Michael Jeffrey Wald; Jeremy Franklin Magland; Chamith Sudesh Rajapakse; Felix Werner Wehrli
Journal:  J Magn Reson Imaging       Date:  2010-05       Impact factor: 4.813

4.  On the significance of motion degradation in high-resolution 3D μMRI of trabecular bone.

Authors:  Yusuf A Bhagat; Chamith S Rajapakse; Jeremy F Magland; Michael J Wald; Hee Kwon Song; Mary B Leonard; Felix W Wehrli
Journal:  Acad Radiol       Date:  2011-08-04       Impact factor: 3.173

5.  Classification of trabeculae into three-dimensional rodlike and platelike structures via local inertial anisotropy.

Authors:  Branimir Vasilić; Chamith S Rajapakse; Felix W Wehrli
Journal:  Med Phys       Date:  2009-07       Impact factor: 4.071

6.  Non-destructive characterization of microdamage in cortical bone using low field pulsed NMR.

Authors:  Daniel P Nicolella; Qingwen Ni; Kwai S Chan
Journal:  J Mech Behav Biomed Mater       Date:  2010-11-21

7.  Helmholtz-pair transmit coil with integrated receive array for high-resolution MRI of trabecular bone in the distal tibia at 7T.

Authors:  Alexander C Wright; Rostislav Lemdiasov; Thomas J Connick; Yusuf A Bhagat; Jeremy F Magland; Hee Kwon Song; Steven P Toddes; Reinhold Ludwig; Felix W Wehrli
Journal:  J Magn Reson       Date:  2011-02-23       Impact factor: 2.229

Review 8.  High-resolution imaging techniques for the assessment of osteoporosis.

Authors:  Roland Krug; Andrew J Burghardt; Sharmila Majumdar; Thomas M Link
Journal:  Radiol Clin North Am       Date:  2010-05       Impact factor: 2.303

9.  Performance of the MRI-based virtual bone biopsy in the distal radius: serial reproducibility and reliability of structural and mechanical parameters in women representative of osteoporosis study populations.

Authors:  Shing Chun Benny Lam; Michael J Wald; Chamith S Rajapakse; Yinxiao Liu; Punam K Saha; Felix W Wehrli
Journal:  Bone       Date:  2011-07-19       Impact factor: 4.398

10.  Registration-based autofocusing technique for automatic correction of motion artifacts in time-series studies of high-resolution bone MRI.

Authors:  Ning Zhang; Jeremy F Magland; Hee Kwon Song; Felix W Wehrli
Journal:  J Magn Reson Imaging       Date:  2014-05-07       Impact factor: 4.813

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.