Literature DB >> 16872930

Marginal accuracy of titanium copings fabricated by casting and CAD/CAM techniques.

Siegbert Witkowski1, Futoshi Komine, Thomas Gerds.   

Abstract

STATEMENT OF PROBLEM: Advances in computer-aided design/computer-assisted manufacturing (CAD/CAM) technology purportedly enhance the marginal fit of dental restorations. However, little information is available on the marginal accuracy of restorations manufactured with various CAD/CAM systems.
PURPOSE: The purpose of this study was to evaluate and compare the marginal accuracy and refinement time of titanium copings fabricated by 3 different CAD/CAM systems relative to standard casting techniques.
MATERIAL AND METHODS: Sixty-four stone die duplicates of a human maxillary central incisor, prepared for a metal-ceramic crown, with a uniform chamfer design, were divided into 4 groups (n=16). The specimens were restored with titanium copings using CAD/CAM systems Pro 50 (PRO), DCS (DCS), and Everest (EVE). A conventional titanium casting technique, Biotan (BIO), served as a control. Vertical and horizontal discrepancies between restoration margins and the preparations were each measured before and after manual refinement. This refinement was completed using a disclosing agent and by removing the internal positive defects of the copings. The marginal discrepancies of the copings were evaluated at 4 standard areas using 10 measurements, for a total of 160 measurements of each margin. Repeated-measures ANOVA was used for analyzing marginal accuracy. The coping refinement time was analyzed with the Kruskal-Wallis and post hoc Wilcoxon rank sum tests (alpha=.05).
RESULTS: The marginal discrepancies (microm) ranged from 32.9 to 127.8 before and from 3.4 to 58.4 after the manual refinement of copings. Manual refinement significantly improved the marginal accuracy (P<.0001) when compared with the initial fabrication. The relative (%) gain of marginal accuracy was PRO, 74.1%; DCS, 69.7%; EVE, 68.7%; and the control, BIO, 69.2%. The median duration of manual refinement time in minutes was 6.0 for PRO, 9.5 for DCS, 4.0 for EVE, and 4.0 for BIO (Kruskal-Wallis-test: P<.0001).
CONCLUSION: Manual adjustment significantly improves the marginal accuracy of CAD/CAM system-fabricated titanium copings. The highest marginal accuracy was achieved with the DCS system, using a longer refinement time.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16872930     DOI: 10.1016/j.prosdent.2006.05.013

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  22 in total

1.  Different CAD/CAM-processing routes for zirconia restorations: influence on fitting accuracy.

Authors:  Philipp Kohorst; Janet Junghanns; Marc P Dittmer; Lothar Borchers; Meike Stiesch
Journal:  Clin Oral Investig       Date:  2010-05-22       Impact factor: 3.573

2.  Parameters affecting retentive force of electroformed double-crown systems.

Authors:  Florian Beuer; Daniel Edelhoff; Wolfgang Gernet; Michael Naumann
Journal:  Clin Oral Investig       Date:  2009-04-03       Impact factor: 3.573

Review 3.  3D printing in dentistry.

Authors:  A Dawood; B Marti Marti; V Sauret-Jackson; A Darwood
Journal:  Br Dent J       Date:  2015-12       Impact factor: 1.626

4.  Metal-ceramic-fixed dental prosthesis with CAD/CAM-fabricated substructures: 6-year clinical results.

Authors:  Jeremias Hey; Florian Beuer; Tobias Bensel; Arne F Boeckler
Journal:  Clin Oral Investig       Date:  2012-09-29       Impact factor: 3.573

5.  Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs).

Authors:  Florian Beuer; Daniel Edelhoff; Wolfgang Gernet; John A Sorensen
Journal:  Clin Oral Investig       Date:  2009-01-24       Impact factor: 3.573

6.  In vitro evaluation of fracture strength of zirconia restoration veneered with various ceramic materials.

Authors:  Yu-Sung Choi; Sung-Hun Kim; Jai-Bong Lee; Jung-Suk Han; In-Sung Yeo
Journal:  J Adv Prosthodont       Date:  2012-08-28       Impact factor: 1.904

7.  Marginal and internal fit evaluation of conventional metal-ceramic versus zirconia CAD/CAM crowns.

Authors:  Nayana Paul; K N Raghavendra Swamy; M R Dhakshaini; Sanjukta Sowmya; M B Ravi
Journal:  J Clin Exp Dent       Date:  2020-01-01

8.  Comparison of marginal and internal fit of three-unit implant-supported fixed prosthetic substructures fabricated using CAD/CAM systems.

Authors:  Ozlem Kayikci; Sabit Melih Ates
Journal:  Clin Oral Investig       Date:  2021-07-31       Impact factor: 3.573

9.  Marginal and internal fit of zirconia based fixed dental prostheses fabricated with different concepts.

Authors:  Florian Beuer; Natalie Korczynski; Antonia Rezac; Michael Naumann; Wolfgang Gernet; John A Sorensen
Journal:  Clin Cosmet Investig Dent       Date:  2010-02-25

10.  Evaluation of marginal fit of 2 CAD-CAM anatomic contour zirconia crown systems and lithium disilicate glass-ceramic crown.

Authors:  Min-Kyung Ji; Ji-Hee Park; Sang-Won Park; Kwi-Dug Yun; Gye-Jeong Oh; Hyun-Pil Lim
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.