Literature DB >> 20922439

Influence of the fabrication process on the in vitro performance of fixed dental prostheses with zirconia substructures.

Martin Rosentritt1, Carola Kolbeck, Gerhard Handel, Sibylle Schneider-Feyrer, Michael Behr.   

Abstract

Chipping of the applied veneering ceramic is reported to be a main clinical failure type of computer-aided design/computer-aided manufacturing- or manually copy-milled zirconia restorations. The aim of this in vitro study was to investigate whether different substructure designs and veneering processes done by different dental technicians do significantly influence chipping in zirconia-based all-ceramic fixed dental prostheses during simulated oral service. Five groups (n = 8 per group) of three-unit zirconia substructures were fabricated in three different laboratories using copy-milling technique. Three series were veneered with identical porcelain (groups 1-3) and one with a second different porcelain (group 4). The fifth group was milled to final contour design without veneering. Dimensions of the connector areas were determined. All fixed partial dentures (FPDs) were adhesively boned on human teeth and thermally cycled and mechanically loaded (1.2 × 10(6) × 50 N; 6,000 × 5°C/55°C) using human antagonists. Restorations were monitored during thermal cycling and mechanical loading (TCML). FPDs which survived were loaded to fracture. FPDs which failed during TCML were investigated with fractographic means. During TCML, chipping took place in groups 1 (two times), 2 (four times) and 3 (five times) (Table 1). Chipping areas varied between 2.3 mm(2) (group 3) and 58.7 mm(2) (group 2). Groups 4 and 5 provided no failures during TCML. Failure in all cases started from contact points, where superficial wear and disruption of the porcelain were found. No significant correlation could be determined between connector thickness and number of failures. Median fracture results varied between 1,011 N (group 3) and 2,126 N (group 2). The results show the necessity of considering individual design and manufacturing of restorations as well as contact situation. Advanced technical training on zirconia-based restorations is recommended.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20922439     DOI: 10.1007/s00784-010-0469-8

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  27 in total

Review 1.  Clinically relevant approach to failure testing of all-ceramic restorations.

Authors:  J R Kelly
Journal:  J Prosthet Dent       Date:  1999-06       Impact factor: 3.426

2.  Dental ceramics and the molar crown testing ground.

Authors:  Van P Thompson; Dianne E Rekow
Journal:  J Appl Oral Sci       Date:  2004       Impact factor: 2.698

3.  The influence of design parameters on the FEA-determined stress distribution in CAD-CAM produced all-ceramic dental crowns.

Authors:  Niek De Jager; Prem Pallav; Albert J Feilzer
Journal:  Dent Mater       Date:  2005-03       Impact factor: 5.304

4.  Failure analysis of ceramic clinical cases using qualitative fractography.

Authors:  Susanne S Scherrer; Janet B Quinn; George D Quinn; J Robert Kelly
Journal:  Int J Prosthodont       Date:  2006 Mar-Apr       Impact factor: 1.681

5.  Flexural strength of veneering ceramics for zirconia.

Authors:  J Fischer; B Stawarczyk; C H F Hämmerle
Journal:  J Dent       Date:  2008-03-14       Impact factor: 4.379

6.  Five-year clinical results of zirconia frameworks for posterior fixed partial dentures.

Authors:  Irena Sailer; Aurel Fehér; Frank Filser; Ludwig J Gauckler; Heinz Lüthy; Christoph Hans Franz Hämmerle
Journal:  Int J Prosthodont       Date:  2007 Jul-Aug       Impact factor: 1.681

7.  Clinical behavior of zirconia-based fixed partial dentures made of DC-Zirkon: 3-year results.

Authors:  Joachim Tinschert; Karen A Schulze; Gerd Natt; Peter Latzke; Nicole Heussen; Hubertus Spiekermann
Journal:  Int J Prosthodont       Date:  2008 May-Jun       Impact factor: 1.681

Review 8.  Clinical trials in zirconia: a systematic review.

Authors:  B Al-Amleh; K Lyons; M Swain
Journal:  J Oral Rehabil       Date:  2010-04-09       Impact factor: 3.837

9.  Approach for valuating the significance of laboratory simulation.

Authors:  Martin Rosentritt; Georgios Siavikis; Michael Behr; Carola Kolbeck; Gerhard Handel
Journal:  J Dent       Date:  2008-10-09       Impact factor: 4.379

10.  Effects of geometry on fracture initiation and propagation in all-ceramic crowns.

Authors:  E Dianne Rekow; Guangming Zhang; Van Thompson; Jae-Won Kim; Paulo Coehlo; Yu Zhang
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2009-02       Impact factor: 3.368

View more
  4 in total

1.  Influence of cusp inclination and curvature on the in vitro failure and fracture resistance of veneered zirconia crowns.

Authors:  Verena Preis; Thomas Dowerk; Michael Behr; Carola Kolbeck; Martin Rosentritt
Journal:  Clin Oral Investig       Date:  2013-07-12       Impact factor: 3.573

2.  Influence of the supporting die structures on the fracture strength of all-ceramic materials.

Authors:  Munir Tolga Yucel; Isa Yondem; Filiz Aykent; Oğuz Eraslan
Journal:  Clin Oral Investig       Date:  2011-08-16       Impact factor: 3.573

3.  In vitro performance and fracture resistance of CAD/CAM-fabricated implant supported molar crowns.

Authors:  Martin Rosentritt; Sebastian Hahnel; Frank Engelhardt; Michael Behr; Verena Preis
Journal:  Clin Oral Investig       Date:  2016-07-01       Impact factor: 3.573

4.  Maxillary rehabilitation of periodontally compromised patients with extensive one-piece fixed prostheses supported by natural teeth: a retrospective longitudinal study.

Authors:  Alexander Heschl; Michael Haas; Josef Haas; Michael Payer; Walther Wegscheider; Raoul Polansky
Journal:  Clin Oral Investig       Date:  2013-01       Impact factor: 3.573

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.