Literature DB >> 17681371

Fatigue and fracture properties of yttria partially stabilized zirconia crown systems.

Eleftheria Tsalouchou1, Mike J Cattell, Jonathan C Knowles, Piyapanna Pittayachawan, Ailbhe McDonald.   

Abstract

OBJECTIVES: The purpose of this study was to test in vitro the fatigue and fracture properties of the Zirconia Everest core material after being veneered with a sintered or a heat-pressed veneer material.
METHODS: Fifty zirconium copings were made using Kavo Everest ZS-blanks and the CAD/CAM technology. These were divided equally into two groups. Group one was veneered by a heat-pressed material (IPS e.max ZirPress) and group two was veneered by a sintered material (IPS e.max Ceram). All the crown shapes were subjected to 50,000 cycles of cyclic loading in water between 20 and 200 N, at a rate of 1 Hz and then loaded dynamically at a crosshead speed of 1 mm/min, until failure. Specimens of the core and the veneering materials were characterized using X-ray diffraction (XRD) and secondary electron imaging (SEI).
RESULTS: There was no statistically significant difference in the mean failure load (N+/-S.D.) between group 1: 2135.6+/-330.1 and group 2: 2189.9.1+/-317.6 (p>0.05). No difference was found in the Weibull modulus and characteristic failure load values between the two groups (p>0.05). The specimens displayed mainly cohesive failure within the veneering material. XRD of the zirconium powder before sintering revealed tetragonal and monoclinic phases while after sintering only tetragonal zirconia could be identified. SIGNIFICANCE: There was no difference in the fatigue properties of the Zirconia Everest core material following sintering or heat pressing of the veneering material (p>0.05).

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17681371     DOI: 10.1016/j.dental.2007.05.011

Source DB:  PubMed          Journal:  Dent Mater        ISSN: 0109-5641            Impact factor:   5.304


  17 in total

1.  Laboratory simulation of Y-TZP all-ceramic crown clinical failures.

Authors:  P G Coelho; E A Bonfante; N R F Silva; E D Rekow; V P Thompson
Journal:  J Dent Res       Date:  2009-04       Impact factor: 6.116

Review 2.  Evaluation of success rate of Zirconia based restorations: A systematic review.

Authors:  Aditee Apte; Seema Sathe; Rewa Kawade
Journal:  J Clin Exp Dent       Date:  2022-09-01

3.  Comparison of fracture toughness of all-ceramic and metal-ceramic cement retained implant crowns: an in vitro study.

Authors:  S Rao; R Chowdhary
Journal:  J Indian Prosthodont Soc       Date:  2014-01-21

4.  Fracture resistance and failure mode of posterior fixed dental prostheses fabricated with two zirconia CAD/CAM systems.

Authors:  Carlos López-Suárez; Esther Gonzalo; Jesús Peláez; Verónica Rodríguez; María-Jesús Suárez
Journal:  J Clin Exp Dent       Date:  2015-04-01

5.  Three-year clinical prospective evaluation of zirconia-based posterior fixed dental prostheses (FDPs).

Authors:  Florian Beuer; Daniel Edelhoff; Wolfgang Gernet; John A Sorensen
Journal:  Clin Oral Investig       Date:  2009-01-24       Impact factor: 3.573

6.  Long-term fracture load of all-ceramic crowns: Effects of veneering ceramic thickness, application techniques, and cooling protocol.

Authors:  Júlia-Magalhães-da Costa Lima; João-Paulo-Mendes Tribst; Lilian-Costa Anami; Renata-Marques de Melo; Dayanne-Monielle-Duarte Moura; Rodrigo-Othávio-Assunção Souza; Marco-Antonio Bottino
Journal:  J Clin Exp Dent       Date:  2020-11-01

7.  In vitro evaluation of fracture strength of zirconia restoration veneered with various ceramic materials.

Authors:  Yu-Sung Choi; Sung-Hun Kim; Jai-Bong Lee; Jung-Suk Han; In-Sung Yeo
Journal:  J Adv Prosthodont       Date:  2012-08-28       Impact factor: 1.904

8.  The effect of various veneering techniques on the marginal fit of zirconia copings.

Authors:  Kianoosh Torabi; Mahroo Vojdani; Rashin Giti; Masumeh Taghva; Soheil Pardis
Journal:  J Adv Prosthodont       Date:  2015-06-23       Impact factor: 1.904

9.  Post-fatigue fracture resistance of metal core crowns: press-on metal ceramic versus a conventional veneering system.

Authors:  M Fernanda Solá-Ruiz; Rubén Agustín-Panadero; Carlos Campos-Estellés; Carlos Labaig-Rueda
Journal:  J Clin Exp Dent       Date:  2015-04-01

Review 10.  Zirconia in fixed prosthesis. A literature review.

Authors:  Rubén Agustín-Panadero; Juan L Román-Rodríguez; Alberto Ferreiroa; María F Solá-Ruíz; Antonio Fons-Font
Journal:  J Clin Exp Dent       Date:  2014-02-01
View more