Dose reduction in computed tomography: the effect of eye and testicle shielding on radiation dose measured in patients with beryllium oxide-based optically stimulated luminescence dosimetry.

Henrik Grobe1, Marian Sommer, Arne Koch, Volker Hietschold, Jürgen Henniger, Nasreddin Abolmaali.   

Abstract

The aim of this study was to assess the effect of eye and testicle shielding on radiation dose to the lens and the testes of patients undergoing CT examinations. Fifty-one male patients underwent CT twice with identical protocols initially without, the second time with protective garments. Doses to the testes and the lenses were recorded with beryllium oxide-based dosimeters. The dose to the testes and lenses from CT exposure was reduced by 96.2% +/- 1.7% and 28.2% +/- 18.5%, when testicle and eye shielding was used, respectively. The effect of the eye shielding on the eye lens dose was found to depend on the x-ray tube position when the eye is primarily exposed during the scan. The maximum eye lens dose reduction achieved was found to be 43.2% +/- 6.5% corresponding to the anterior position of the tube. A significant correlation between the patient's body mass index and dose exposure could not be found. Eye and testicle shields, apart from being inexpensive and easy to use, were proven to be effective in reducing eye lens and testicle radiation dose burden from CT exposures.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19082601     DOI: 10.1007/s00330-008-1241-1

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  13 in total

1.  Reproducibility of multi-slice spiral computed tomography scans: an experimental study.

Authors:  Marcel van Straten; Henk W Venema; Joris Hartman; Gerard J den Heeten; Cornelis A Grimbergen
Journal:  Med Phys       Date:  2004-10       Impact factor: 4.071

2.  The effect of z overscanning on patient effective dose from multidetector helical computed tomography examinations.

Authors:  A Tzedakis; J Damilakis; K Perisinakis; J Stratakis; N Gourtsoyiannis
Journal:  Med Phys       Date:  2005-06       Impact factor: 4.071

3.  Investigation of a BeO-based optically stimulated luminescence dosemeter.

Authors:  M Sommer; J Henniger
Journal:  Radiat Prot Dosimetry       Date:  2006-05-30       Impact factor: 0.972

4.  Radiation dose reduction to the male gonads during MDCT: the effectiveness of a lead shield.

Authors:  Christian Hohl; Andreas H Mahnken; Ernst Klotz; Marco Das; Achim Stargardt; Georg Mühlenbruch; Thorsten Schmidt; Rolf W Günther; Joachim E Wildberger
Journal:  AJR Am J Roentgenol       Date:  2005-01       Impact factor: 3.959

5.  Quantification of beta+ activity generated by hard photons by means of PET.

Authors:  D Möckel; H Müller; J Pawelke; M Sommer; E Will; W Enghardt
Journal:  Phys Med Biol       Date:  2007-04-10       Impact factor: 3.609

6.  Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions.

Authors:  H Greess; H Wolf; U Baum; M Lell; M Pirkl; W Kalender; W A Bautz
Journal:  Eur Radiol       Date:  2000       Impact factor: 5.315

7.  Risk of cataract after exposure to low doses of ionizing radiation: a 20-year prospective cohort study among US radiologic technologists.

Authors:  Gabriel Chodick; Nural Bekiroglu; Michael Hauptmann; Bruce H Alexander; D Michal Freedman; Michele Morin Doody; Li C Cheung; Steven L Simon; Robert M Weinstock; André Bouville; Alice J Sigurdson
Journal:  Am J Epidemiol       Date:  2008-07-29       Impact factor: 4.897

8.  Radiation dose to the lens and cataract formation.

Authors:  J M Henk; R A Whitelocke; A P Warrington; E M Bessell
Journal:  Int J Radiat Oncol Biol Phys       Date:  1993-04-02       Impact factor: 7.038

9.  [Computed tomography: influence of varying tube current on patient dose and correctness of effective dose calculations].

Authors:  V Hietschold; A Koch; M Laniado; N D Abolmaali
Journal:  Rofo       Date:  2008-05

10.  Radiation dose reduction at a price: the effectiveness of a male gonadal shield during helical CT scans.

Authors:  Lawrence T Dauer; Kevin A Casciotta; Yusuf E Erdi; Lawrence N Rothenberg
Journal:  BMC Med Imaging       Date:  2007-03-16       Impact factor: 1.930

View more
  6 in total

Review 1.  [Strategies for reducing the CT radiation dose].

Authors:  S T Schindera; C Nauer; R Treier; P Trueb; G von Allmen; P Vock; Z Szucs-Farkas
Journal:  Radiologe       Date:  2010-12       Impact factor: 0.635

2.  Prevalence of Protective Shielding Utilization for Radiation Dose Reduction in Adult Patients Undergoing Body Scanning Using Computed Tomography.

Authors:  Shoaib Safiullah; Roshan Patel; Brittany Uribe; Kyle Spradling; Chandana Lall; Lishi Zhang; Zhamshid Okhunov; Ralph V Clayman; Jaime Landman
Journal:  J Endourol       Date:  2017-08-14       Impact factor: 2.942

3.  Signal-to-noise ratio and dose to the lens of the eye for computed tomography examination of the brain using an automatic tube current modulation system.

Authors:  Supawitoo Sookpeng; Chitsanupong Butdee
Journal:  Emerg Radiol       Date:  2016-12-02

4.  Can Common Lead Apron in Testes Region Cause Radiation Dose Reduction during Chest CT Scan? A Patient Study.

Authors:  Mohammad Kiapour; Kourosh Ebrahimnejad Gorji; Rahele Mehraeen; Naser Ghaemian; Fatemeh Niksirat Sustani; Razzagh Abedi-Firouzjah; Ali Shabestani Monfared
Journal:  J Biomed Phys Eng       Date:  2021-08-01

5.  Catheter ablation of arrhythmias exclusively using electroanatomic mapping: a series of cases.

Authors:  Leonardo Martins Pires; Tiago Luiz Luz Leiria; Marcelo Lapa Kruse; Rafael Ronsoni; Caroline Saltz Gensas; Gustavo Glotz de Lima
Journal:  Arq Bras Cardiol       Date:  2013-07-23       Impact factor: 2.000

6.  Lower abdominal and pelvic radiation and testicular germ cell tumor risk.

Authors:  Kevin T Nead; Nandita Mitra; Benita Weathers; Louisa Pyle; Nnadozie Emechebe; Donna A Pucci; Linda A Jacobs; David J Vaughn; Katherine L Nathanson; Peter A Kanetsky
Journal:  PLoS One       Date:  2020-11-11       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.