Literature DB >> 10663775

Dose reduction in computed tomography by attenuation-based on-line modulation of tube current: evaluation of six anatomical regions.

H Greess1, H Wolf, U Baum, M Lell, M Pirkl, W Kalender, W A Bautz.   

Abstract

This study investigated the potential of attenuation-based on-line modulation of tube current to reduce the dose of computed tomography (in milliamperes) without loss in image quality. The dose can be reduced for non-circular patient cross-sections by reducing the tube current at the angular positions at which the diameter through the patient diameter is smallest. We investigated a new technical approach with attenuation-based on-line modulation of tube current. Computed tomographic projection data were analyzed to determine the optimal milliampere values for each projection angle in real time, instead of performing prior measurements with localizer radiographs. We compared image quality, noise pattern, and dose for standard scans and for scans with attenuation-based on-line modulation of tube current in a group of 30 radiation therapy patients. Six different anatomical regions were examined: head, shoulder, thorax, abdomen, pelvis, and extremities (knee). Image quality was evaluated by four radiologists in a blinded fashion. We found the dose to be reduced typically by 15-50 %. In general, no deterioration in image quality was observed. Thus the dose in computed tomography be reduced substantially by technical measures without sacrificing image quality. Attenuation-based on-line modulation of tube current is an efficient and practical means for this.

Entities:  

Mesh:

Year:  2000        PMID: 10663775     DOI: 10.1007/s003300050062

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  55 in total

1.  Management of patient dose and image noise in routine pediatric CT abdominal examinations.

Authors:  Francis R Verdun; D Lepori; Pascal Monnin; Jean-François Valley; Pierre Schnyder; F Gudinchet
Journal:  Eur Radiol       Date:  2004-01-13       Impact factor: 5.315

Review 2.  Contrast-enhanced MDCT of the thorax.

Authors:  A F Kopp; A Küttner; T Trabold; M Heuschmid; S Schröder; C D Claussen
Journal:  Eur Radiol       Date:  2003-11       Impact factor: 5.315

Review 3.  Cardiac and vascular MDCT: thoracic imaging.

Authors:  Andreas F Kopp; Axel Küttner; Tobias Trabold; Martin Heuschmid; Stephen Schröder; C D Claussen
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

Review 4.  Optimizing technique for multi-slice CT.

Authors:  Sanjay Saini; Roy V Dsouza
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

Review 5.  Multislice CT: update on radiation and screening.

Authors:  Mannudeep K Kalra; Michael M Maher; Sanjay Saini
Journal:  Eur Radiol       Date:  2003-12       Impact factor: 5.315

6.  Automatic tube current modulation technique for multidetector CT: is it effective with a 64-detector CT?

Authors:  Yoshinori Funama; Kazuo Awai; Masahiro Hatemura; Masamitchi Shimamura; Yumi Yanaga; Seitaro Oda; Yasuyuki Yamashita
Journal:  Radiol Phys Technol       Date:  2007-11-01

Review 7.  Reducing radiation dose in emergency computed tomography with automatic exposure control techniques.

Authors:  Mannudeep K Kalra; Stefania M R Rizzo; Robert A Novelline
Journal:  Emerg Radiol       Date:  2005-05-12

8.  The influences of tube voltage and scan direction on combined tube current modulation: a phantom study.

Authors:  Hyun Woo Goo; Dong Soo Suh
Journal:  Pediatr Radiol       Date:  2006-04-27

9.  Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer.

Authors:  Rebecca Smith-Bindman; Jafi Lipson; Ralph Marcus; Kwang-Pyo Kim; Mahadevappa Mahesh; Robert Gould; Amy Berrington de González; Diana L Miglioretti
Journal:  Arch Intern Med       Date:  2009-12-14

10.  Improvement of image quality of multislice spiral CT scans of the head and neck region using a raw data-based multidimensional adaptive filtering (MAF) technique.

Authors:  Ulrich Baum; Katharina Anders; Gregor Steinbichler; Michael Lell; Holger Greess; Thomas Riedel; Marc Kachelriess; Willi A Kalender; Werner A Bautz
Journal:  Eur Radiol       Date:  2004-08-24       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.