Literature DB >> 19034597

Results of press-fit stems in revision knee arthroplasties.

Gavin C Wood1, Douglas D R Naudie, Steven J MacDonald, Richard W McCalden, Robert B Bourne.   

Abstract

The ideal method of stem fixation in revision knee arthroplasty is controversial with advantages and disadvantages for cemented and press-fit designs. Studies have suggested cemented revision knee stems may provide better long-term survival. The aim of this study was to report our experience with press-fit uncemented stems and metaphyseal cement fixation in a selected series of patients undergoing revision total knee arthroplasty. One hundred twenty-seven patients (135 knees) who underwent revision total knee arthroplasty using a press-fit technique (press-fit diaphyseal fixation and cemented metaphyseal fixation) were reviewed. Minimum followup was 2 years (mean, 5 years; range, 2-12 years). A Kaplan-Meier survivorship analysis using an end point of revision surgery or radiographic loosening was used to determine probability of survival at 5 and 10 years. Of the 127 patients (135 knees), 31 patients (36 knees) died and two patients (two knees) were lost to followup. Six patients (six knees) had revisions at a mean of 3.5 years (range, 1-8 years). Kaplan-Meier survivorship analysis revealed a probability of survival free of revision for aseptic loosening of 98% at 12 years. Survivorship of press-fit stems for revision knee arthroplasty is comparable to reported survivorship of cemented stem revision knee arthroplasty. Radiographic analysis has shown continued satisfactory appearances regardless of constraint, stem size, and augmentations.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19034597      PMCID: PMC2635433          DOI: 10.1007/s11999-008-0621-9

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  21 in total

1.  Revision total knee arthroplasty with use of modular components with stems inserted without cement.

Authors:  S B Haas; J N Insall; W Montgomery; R E Windsor
Journal:  J Bone Joint Surg Am       Date:  1995-11       Impact factor: 5.284

2.  The effect of a stem on the tibial component of knee arthroplasty. A roentgen stereophotogrammetric study of uncemented tibial components in the Freeman-Samuelson knee arthroplasty.

Authors:  B E Albrektsson; L Ryd; L V Carlsson; M A Freeman; P Herberts; L Regnér; G Selvik
Journal:  J Bone Joint Surg Br       Date:  1990-03

3.  Total condylar III knee prosthesis. Long-term follow-up study.

Authors:  W F Donaldson; T P Sculco; J N Insall; C S Ranawat
Journal:  Clin Orthop Relat Res       Date:  1988-01       Impact factor: 4.176

4.  Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic review.

Authors:  R L Barrack; R D Mulroy; W H Harris
Journal:  J Bone Joint Surg Br       Date:  1992-05

5.  The influence of tibial component intramedullary stems and implant-cortex contact on the strain distribution of the proximal tibia following total knee arthroplasty. An in vitro study.

Authors:  R B Bourne; J B Finlay
Journal:  Clin Orthop Relat Res       Date:  1986-07       Impact factor: 4.176

Review 6.  Bone loss with revision total knee arthroplasty: defect classification and alternatives for reconstruction.

Authors:  G A Engh; D J Ammeen
Journal:  Instr Course Lect       Date:  1999

7.  Hybrid component fixation in revision total knee arthroplasty.

Authors:  Friedrich Bottner; Richard Laskin; Russell E Windsor; Steven B Haas
Journal:  Clin Orthop Relat Res       Date:  2006-05       Impact factor: 4.176

8.  Tibial component fixation in deficient tibial bone stock.

Authors:  P J Brooks; P S Walker; R D Scott
Journal:  Clin Orthop Relat Res       Date:  1984-04       Impact factor: 4.176

9.  Cemented long-stem revision total knee arthroplasty.

Authors:  P B Murray; J A Rand; A D Hanssen
Journal:  Clin Orthop Relat Res       Date:  1994-12       Impact factor: 4.176

10.  Femoral component loosening using contemporary techniques of femoral cement fixation.

Authors:  W H Harris; J C McCarthy; D A O'Neill
Journal:  J Bone Joint Surg Am       Date:  1982-09       Impact factor: 5.284

View more
  23 in total

Review 1.  Fixation of revision TKA: a review of the literature.

Authors:  J Beckmann; C Lüring; R Springorum; F X Köck; J Grifka; M Tingart
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-09-07       Impact factor: 4.342

2.  Extent of vertical cementing as a predictive factor for radiolucency in revision total knee arthroplasty.

Authors:  Du Hyun Ro; Yool Cho; Sahnghoon Lee; Kee Yun Chung; Seong Hwan Kim; Young Min Lee; Joon Kyu Lee; Myung Chul Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-02-01       Impact factor: 4.342

3.  Modified hybrid stem fixation in revision TKA is durable at 2 to 10 years.

Authors:  Alexander P Sah; Sanjai Shukla; Craig J Della Valle; Aaron G Rosenberg; Wayne G Paprosky
Journal:  Clin Orthop Relat Res       Date:  2010-09-28       Impact factor: 4.176

4.  [Defect Reconstruction in Total Knee Arthroplasty with wedges and blocks]. [Corrected].

Authors:  R Hube; T Pfitzner; P von Roth; H O Mayr
Journal:  Oper Orthop Traumatol       Date:  2015-02-04       Impact factor: 1.154

5.  Computer-assisted navigation is beneficial both in primary and revision surgery with modular rotating-hinge knee arthroplasty.

Authors:  Björn G Ochs; Anna J Schreiner; Peter M de Zwart; Ulrich Stöckle; Christoph Emanuel Gonser
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-09-20       Impact factor: 4.342

6.  [TKA revision of semiconstraint components using the 3-step technique].

Authors:  R Hube; G Matziolis; T Kalteis; H O Mayr
Journal:  Oper Orthop Traumatol       Date:  2011-02       Impact factor: 1.154

7.  Handheld computer-navigated constrained total knee arthroplasty for complex extra-articular deformities.

Authors:  M Pietsch; M Hochegger; O Djahani; G Mlaker; M Eder-Halbedl; Th Hofstädter
Journal:  Arch Orthop Trauma Surg       Date:  2021-07-13       Impact factor: 3.067

8.  Comparison between uncemented and cemented fixation for the tibial component in distal femoral replacement: a clinical and radiological study.

Authors:  Haijie Liang; Wei Guo; Rongli Yang; Xiaodong Tang; Taiqiang Yan
Journal:  Int Orthop       Date:  2018-02-24       Impact factor: 3.075

Review 9.  Fixation of stem in revision of total knee arthroplasty: cemented versus cementless-a meta-analysis.

Authors:  Changyao Wang; Tilman Pfitzner; Philipp von Roth; Hermann O Mayr; Michael Sostheim; Robert Hube
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-12-19       Impact factor: 4.342

10.  A sliding stem in revision total knee arthroplasty provides stability and reduces stress shielding.

Authors:  Huub J Meijerink; Corné J M van Loon; Maarten C de Waal Malefijt; Albert van Kampen; Nico Verdonschot
Journal:  Acta Orthop       Date:  2010-06       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.