Literature DB >> 2312565

The effect of a stem on the tibial component of knee arthroplasty. A roentgen stereophotogrammetric study of uncemented tibial components in the Freeman-Samuelson knee arthroplasty.

B E Albrektsson1, L Ryd, L V Carlsson, M A Freeman, P Herberts, L Regnér, G Selvik.   

Abstract

We studied the effect of a metal tray with an intramedullary stem on the micromotion of the tibial component in total knee arthroplasty. Of 32 uncemented Freeman-Samuelson knee arthroplasties performed in London and Gothenburg, nine had a metal backing and stem added to the tibial component. Micromotion of the tibial components, expressed as migration and inducible displacement, was analysed using roentgen stereophotogrammetric analysis up to two years follow-up. The addition of a metal back and a 110 mm stem to the standard polyethylene component significantly reduced both migration over two years and inducible displacement.

Entities:  

Mesh:

Year:  1990        PMID: 2312565

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  13 in total

1.  Extent of vertical cementing as a predictive factor for radiolucency in revision total knee arthroplasty.

Authors:  Du Hyun Ro; Yool Cho; Sahnghoon Lee; Kee Yun Chung; Seong Hwan Kim; Young Min Lee; Joon Kyu Lee; Myung Chul Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-02-01       Impact factor: 4.342

2.  The influence of metal backing in unicompartmental tibial component fixation. An in vivo roentgen stereophotogrammetric analysis of micromotion.

Authors:  L Ryd; A Lindstrand; A Stenström; G Selvik
Journal:  Arch Orthop Trauma Surg       Date:  1992       Impact factor: 3.067

3.  Modified hybrid stem fixation in revision TKA is durable at 2 to 10 years.

Authors:  Alexander P Sah; Sanjai Shukla; Craig J Della Valle; Aaron G Rosenberg; Wayne G Paprosky
Journal:  Clin Orthop Relat Res       Date:  2010-09-28       Impact factor: 4.176

4.  Results of press-fit stems in revision knee arthroplasties.

Authors:  Gavin C Wood; Douglas D R Naudie; Steven J MacDonald; Richard W McCalden; Robert B Bourne
Journal:  Clin Orthop Relat Res       Date:  2008-11-26       Impact factor: 4.176

5.  Average 10.1-year follow-up of cementless total knee arthroplasty in patients with rheumatoid arthritis.

Authors:  Young Kyun Woo; Ki Won Kim; Jin Wha Chung; Hwa Sung Lee
Journal:  Can J Surg       Date:  2011-06       Impact factor: 2.089

Review 6.  All-polyethylene tibial components are equal to metal-backed components: systematic review and meta-regression.

Authors:  Klaas Auke Nouta; Wiebe C Verra; Bart G Pijls; Jan W Schoones; Rob G H H Nelissen
Journal:  Clin Orthop Relat Res       Date:  2012-09-13       Impact factor: 4.176

7.  Are cementless stems more durable than cemented stems in two-stage revisions of infected total knee arthroplasties?

Authors:  Paul K Edwards; Thomas K Fehring; William G Hamilton; Brett Perricelli; Walter B Beaver; Susan M Odum
Journal:  Clin Orthop Relat Res       Date:  2014-01       Impact factor: 4.176

Review 8.  Early migration of tibial components is associated with late revision: a systematic review and meta-analysis of 21,000 knee arthroplasties.

Authors:  Bart G Pijls; Edward R Valstar; Klaas-Auke Nouta; Josepha Wm Plevier; Marta Fiocco; Saskia Middeldorp; Rob Ghh Nelissen
Journal:  Acta Orthop       Date:  2012-11-09       Impact factor: 3.717

9.  Results of revision total knee arthroplasty using press-fit cementless stem.

Authors:  Maurício Masasi Iamaguchi; Fernando Bley Vicente de Castro; Riccardo Gomes Gobbi; Luis Eduardo Passarelli Tirico; José Ricardo Pécora; Gilberto Luis Camanho
Journal:  Acta Ortop Bras       Date:  2013-01       Impact factor: 0.513

10.  Non-Sagittal Knee Joint Kinematics and Kinetics during Gait on Level and Sloped Grounds with Unicompartmental and Total Knee Arthroplasty Patients.

Authors:  Igor Komnik; Markus Peters; Johannes Funken; Sina David; Stefan Weiss; Wolfgang Potthast
Journal:  PLoS One       Date:  2016-12-21       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.