Rapid calibration for 3-D freehand ultrasound.

R W Prager1, R N Rohling, A H Gee, L Berman.   

Abstract

3-D freehand ultrasound is a new imaging technique that is rapidly finding clinical applications. A position-sensing device is attached to a conventional ultrasound probe so that, as B-scans are acquired, they can be labelled with their relative positions and orientations. This allows a 3-D data set to be constructed from the B-scans. A key requirement of all freehand imaging systems is calibration; that is, determining the position and orientation of the B-scan with respect to the position sensor. This is typically a lengthy and tedious process that may need repeating every time a sensor is mounted on a probe. This paper describes a new calibration technique that takes only a few minutes to perform and produces results that compare favourably (in terms of both accuracy and precision) with previously published alternatives.

Mesh:

Year:  1998        PMID: 9740387     DOI: 10.1016/s0301-5629(98)00044-1

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  44 in total

1.  Effects of growth on geometry of gastrocnemius muscle in children: a three-dimensional ultrasound analysis.

Authors:  Menno R Bénard; Jaap Harlaar; Jules G Becher; Peter A Huijing; Richard T Jaspers
Journal:  J Anat       Date:  2011-06-02       Impact factor: 2.610

2.  A motion constrained cross-wire phantom for tracked 2D ultrasound calibration.

Authors:  Eivind Lyche Melvaer; Knut Mørken; Eigil Samset
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-10-19       Impact factor: 2.924

3.  Adaptive spatial calibration of a 3D ultrasound system.

Authors:  Alex Hartov; Keith Paulsen; Songbai Ji; Kathryn Fontaine; Marie-Laure Furon; Andrea Borsic; David Roberts
Journal:  Med Phys       Date:  2010-05       Impact factor: 4.071

4.  New prototype neuronavigation system based on preoperative imaging and intraoperative freehand ultrasound: system description and validation.

Authors:  Laurence Mercier; Rolando F Del Maestro; Kevin Petrecca; Anna Kochanowska; Simon Drouin; Charles X B Yan; Andrew L Janke; Sean Jy-Shyang Chen; D Louis Collins
Journal:  Int J Comput Assist Radiol Surg       Date:  2010-10-01       Impact factor: 2.924

5.  Robot-assisted automatic ultrasound calibration.

Authors:  Fereshteh Aalamifar; Alexis Cheng; Younsu Kim; Xiao Hu; Haichong K Zhang; Xiaoyu Guo; Emad M Boctor
Journal:  Int J Comput Assist Radiol Surg       Date:  2016-01-11       Impact factor: 2.924

6.  Medial gastrocnemius muscle growth during adolescence is mediated by increased fascicle diameter rather than by longitudinal fascicle growth.

Authors:  Guido Weide; Peter A Huijing; Josina C Maas; Jules G Becher; Jaap Harlaar; Richard T Jaspers
Journal:  J Anat       Date:  2015-04-16       Impact factor: 2.610

7.  Implementing cost-effective 3-dimensional ultrasound using visual probe localization.

Authors:  Aziah Ali; Rajasvaran Logeswaran
Journal:  J Digit Imaging       Date:  2007-12       Impact factor: 4.056

8.  GPU based real-time instrument tracking with three-dimensional ultrasound.

Authors:  Paul M Novotny; Jeff A Stoll; Nikolay V Vasilyev; Pedro J del Nido; Pierre E Dupont; Todd E Zickler; Robert D Howe
Journal:  Med Image Anal       Date:  2007-07-05       Impact factor: 8.545

9.  Muscle-tendon length and force affect human tibialis anterior central aponeurosis stiffness in vivo.

Authors:  Brent James Raiteri; Andrew Graham Cresswell; Glen Anthony Lichtwark
Journal:  Proc Natl Acad Sci U S A       Date:  2018-03-19       Impact factor: 11.205

10.  A freehand ultrasound elastography system with tracking for in vivo applications.

Authors:  Pezhman Foroughi; Hyun-Jae Kang; Daniel A Carnegie; Mark G van Vledder; Michael A Choti; Gregory D Hager; Emad M Boctor
Journal:  Ultrasound Med Biol       Date:  2012-12-17       Impact factor: 2.998

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.