Low-dose 4D cardiac imaging in small animals using dual source micro-CT.

M Holbrook1, D P Clark, C T Badea.   

Abstract

Micro-CT is widely used in preclinical studies, generating substantial interest in extending its capabilities in functional imaging applications such as blood perfusion and cardiac function. However, imaging cardiac structure and function in mice is challenging due to their small size and rapid heart rate. To overcome these challenges, we propose and compare improvements on two strategies for cardiac gating in dual-source, preclinical micro-CT: fast prospective gating (PG) and uncorrelated retrospective gating (RG). These sampling strategies combined with a sophisticated iterative image reconstruction algorithm provide faster acquisitions and high image quality in low-dose 4D (i.e. 3D  +  Time) cardiac micro-CT. Fast PG is performed under continuous subject rotation which results in interleaved projection angles between cardiac phases. Thus, fast PG provides a well-sampled temporal average image for use as a prior in iterative reconstruction. Uncorrelated RG incorporates random delays during sampling to prevent correlations between heart rate and sampling rate. We have performed both simulations and animal studies to validate these new sampling protocols. Sampling times for 1000 projections using fast PG and RG were 2 and 3 min, respectively, and the total dose was 170 mGy each. Reconstructions were performed using a 4D iterative reconstruction technique based on the split Bregman method. To examine undersampling robustness, subsets of 500 and 250 projections were also used for reconstruction. Both sampling strategies in conjunction with our iterative reconstruction method are capable of resolving cardiac phases and provide high image quality. In general, for equal numbers of projections, fast PG shows fewer errors than RG and is more robust to undersampling. Our results indicate that only 1000-projection based reconstruction with fast PG satisfies a 5% error criterion in left ventricular volume estimation. These methods promise low-dose imaging with a wide range of preclinical applications in cardiac imaging.

Entities:  

Mesh:

Year:  2018        PMID: 29148430      PMCID: PMC5831335          DOI: 10.1088/1361-6560/aa9b45

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  38 in total

1.  Image quality assessment: from error visibility to structural similarity.

Authors:  Zhou Wang; Alan Conrad Bovik; Hamid Rahim Sheikh; Eero P Simoncelli
Journal:  IEEE Trans Image Process       Date:  2004-04       Impact factor: 10.856

2.  Iterative 4D cardiac micro-CT image reconstruction using an adaptive spatio-temporal sparsity prior.

Authors:  Ludwig Ritschl; Stefan Sawall; Michael Knaup; Andreas Hess; Marc Kachelriess
Journal:  Phys Med Biol       Date:  2012-03-05       Impact factor: 3.609

3.  Least-error projection sorting to optimize retrospectively gated cardiac micro-CT of free-breathing mice.

Authors:  Stephen E J Armitage; Steven I Pollmann; Sarah A Detombe; Maria Drangova
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

4.  Temporal resolution improvement in cardiac CT using PICCS (TRI-PICCS): performance studies.

Authors:  Jie Tang; Jiang Hsieh; Guang-Hong Chen
Journal:  Med Phys       Date:  2010-08       Impact factor: 4.071

5.  Cardiorespiratory motion-compensated micro-CT image reconstruction using an artifact model-based motion estimation.

Authors:  Marcus Brehm; Stefan Sawall; Joscha Maier; Sebastian Sauppe; Marc Kachelrieß
Journal:  Med Phys       Date:  2015-04       Impact factor: 4.071

6.  3D forward and back-projection for X-ray CT using separable footprints.

Authors:  Yong Long; Jeffrey A Fessler; James M Balter
Journal:  IEEE Trans Med Imaging       Date:  2010-06-07       Impact factor: 10.048

7.  4D micro-CT for cardiac and perfusion applications with view under sampling.

Authors:  Cristian T Badea; Samuel M Johnston; Yi Qi; G Allan Johnson
Journal:  Phys Med Biol       Date:  2011-05-10       Impact factor: 3.609

8.  Prospective-gated cardiac micro-CT imaging of free-breathing mice using carbon nanotube field emission x-ray.

Authors:  Guohua Cao; Laurel M Burk; Yueh Z Lee; Xiomara Calderon-Colon; Shabana Sultana; Jianping Lu; Otto Zhou
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

9.  Multi-energy CT based on a prior rank, intensity and sparsity model (PRISM).

Authors:  Hao Gao; Hengyong Yu; Stanley Osher; Ge Wang
Journal:  Inverse Probl       Date:  2011-11-01       Impact factor: 2.407

10.  A registration based approach for 4D cardiac micro-CT using combined prospective and retrospective gating.

Authors:  Cristian T Badea; Eduard Schreibmann; Tim Fox
Journal:  Med Phys       Date:  2008-04       Impact factor: 4.071

View more
  6 in total

1.  Sensitization of Vascular Endothelial Cells to Ionizing Radiation Promotes the Development of Delayed Intestinal Injury in Mice.

Authors:  Chang-Lung Lee; Andrea R Daniel; Matt Holbrook; Jeremy Brownstein; Lorraine Da Silva Campos; Stephanie Hasapis; Yan Ma; Luke B Borst; Cristian T Badea; David G Kirsch
Journal:  Radiat Res       Date:  2019-07-02       Impact factor: 2.841

Review 2.  Advances in micro-CT imaging of small animals.

Authors:  D P Clark; C T Badea
Journal:  Phys Med       Date:  2021-07-17       Impact factor: 3.119

3.  Photon-counting cine-cardiac CT in the mouse.

Authors:  Darin P Clark; Matthew Holbrook; Chang-Lung Lee; Cristian T Badea
Journal:  PLoS One       Date:  2019-09-19       Impact factor: 3.240

Review 4.  Emerging methods for the characterization of ischemic heart disease: ultrafast Doppler angiography, micro-CT, photon-counting CT, novel MRI and PET techniques, and artificial intelligence.

Authors:  Martin J Willemink; Akos Varga-Szemes; U Joseph Schoepf; Marina Codari; Koen Nieman; Dominik Fleischmann; Domenico Mastrodicasa
Journal:  Eur Radiol Exp       Date:  2021-03-25

5.  Design and Simulation Study of a CNT-Based Multisource Cubical CT System for Dynamic Objects.

Authors:  Changcheng Gong; Li Zeng; Chengxiang Wang; Lei Ran
Journal:  Scanning       Date:  2018-08-30       Impact factor: 1.932

6.  The impact of respiratory gating on improving volume measurement of murine lung tumors in micro-CT imaging.

Authors:  S J Blocker; M D Holbrook; Y M Mowery; D C Sullivan; C T Badea
Journal:  PLoS One       Date:  2020-02-25       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.