Literature DB >> 18561671

Dedicated breast computed tomography: volume image denoising via a partial-diffusion equation based technique.

Jessie Q Xia1, Joseph Y Lo, Kai Yang, Carey E Floyd, John M Boone.   

Abstract

Dedicated breast computed tomography (CT) imaging possesses the potential for improved lesion detection over conventional mammograms, especially for women with dense breasts. The breast CT images are acquired with a glandular dose comparable to that of standard two-view mammography for a single breast. Due to dose constraints, the reconstructed volume has a non-negligible quantum noise when thin section CT slices are visualized. It is thus desirable to reduce noise in the reconstructed breast volume without loss of spatial resolution. In this study, partial diffusion equation (PDE) based denoising techniques specifically for breast CT were applied at different steps along the reconstruction process and it was found that denoising performed better when applied to the projection data rather than reconstructed data. Simulation results from the contrast detail phantom show that the PDE technique outperforms Wiener denoising as well as adaptive trimmed mean filter. The PDE technique increases its performance advantage relative to Wiener techniques when the photon fluence is reduced. With the PDE technique, the sensitivity for lesion detection using the contrast detail phantom drops by less than 7% when the dose is cut down to 40% of the two-view mammography. For subjective evaluation, the PDE technique was applied to two human subject breast data sets acquired on a prototype breast CT system. The denoised images had appealing visual characteristics with much lower noise levels and improved tissue textures while maintaining sharpness of the original reconstructed volume.

Entities:  

Mesh:

Year:  2008        PMID: 18561671      PMCID: PMC2809732          DOI: 10.1118/1.2903436

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  22 in total

1.  Dedicated breast CT: radiation dose and image quality evaluation.

Authors:  J M Boone; T R Nelson; K K Lindfors; J A Seibert
Journal:  Radiology       Date:  2001-12       Impact factor: 11.105

Review 2.  Clinical practice. Mammographic screening for breast cancer.

Authors:  Suzanne W Fletcher; Joann G Elmore
Journal:  N Engl J Med       Date:  2003-04-24       Impact factor: 91.245

Review 3.  Digital x-ray tomosynthesis: current state of the art and clinical potential.

Authors:  James T Dobbins; Devon J Godfrey
Journal:  Phys Med Biol       Date:  2003-10-07       Impact factor: 3.609

4.  Why should breast tumour detection go three dimensional?

Authors:  Zikuan Chen; Ruola Ning
Journal:  Phys Med Biol       Date:  2003-07-21       Impact factor: 3.609

5.  Simulation study of a quasi-monochromatic beam for x-ray computed mammotomography.

Authors:  Randolph L McKinley; Martin P Tornai; Ehsan Samei; Marques L Bradshaw
Journal:  Med Phys       Date:  2004-04       Impact factor: 4.071

6.  Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography.

Authors:  Jing Wang; Tianfang Li; Hongbing Lu; Zhengrong Liang
Journal:  IEEE Trans Med Imaging       Date:  2006-10       Impact factor: 10.048

7.  Experimental spectral measurements of heavy K-edge filtered beams for x-ray computed mammotomography.

Authors:  D J Crotty; R L McKinley; M P Tornai
Journal:  Phys Med Biol       Date:  2007-01-10       Impact factor: 3.609

Review 8.  Long-term effects of mammography screening: updated overview of the Swedish randomised trials.

Authors:  Lennarth Nyström; Ingvar Andersson; Nils Bjurstam; Jan Frisell; Bo Nordenskjöld; Lars Erik Rutqvist
Journal:  Lancet       Date:  2002-03-16       Impact factor: 79.321

9.  Cone-beam volume CT breast imaging: feasibility study.

Authors:  Biao Chen; Ruola Ning
Journal:  Med Phys       Date:  2002-05       Impact factor: 4.071

10.  Dedicated breast CT: initial clinical experience.

Authors:  Karen K Lindfors; John M Boone; Thomas R Nelson; Kai Yang; Alexander L C Kwan; DeWitt F Miller
Journal:  Radiology       Date:  2008-01-14       Impact factor: 11.105

View more
  11 in total

1.  An analysis of the mechanical parameters used for finite element compression of a high-resolution 3D breast phantom.

Authors:  Christina M L Hsu; Mark L Palmeri; W Paul Segars; Alexander I Veress; James T Dobbins
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

2.  Population of 224 realistic human subject-based computational breast phantoms.

Authors:  David W Erickson; Jered R Wells; Gregory M Sturgeon; Ehsan Samei; James T Dobbins; W Paul Segars; Joseph Y Lo
Journal:  Med Phys       Date:  2016-01       Impact factor: 4.071

3.  Methodology for generating a 3D computerized breast phantom from empirical data.

Authors:  Christina M Li; W Paul Segars; Georgia D Tourassi; John M Boone; James T Dobbins
Journal:  Med Phys       Date:  2009-07       Impact factor: 4.071

4.  The incidence and outcome of incidental breast lesions detected by computed tomography.

Authors:  A Hussain; A Gordon-Dixon; H Almusawy; P Sinha; A Desai
Journal:  Ann R Coll Surg Engl       Date:  2009-12-07       Impact factor: 1.891

5.  Investigation of iterative image reconstruction in low-dose breast CT.

Authors:  Junguo Bian; Kai Yang; John M Boone; Xiao Han; Emil Y Sidky; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2014-05-01       Impact factor: 3.609

6.  Effect of slice thickness on detectability in breast CT using a prewhitened matched filter and simulated mass lesions.

Authors:  Nathan J Packard; Craig K Abbey; Kai Yang; John M Boone
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

Review 7.  Applications of nonlocal means algorithm in low-dose X-ray CT image processing and reconstruction: A review.

Authors:  Hao Zhang; Dong Zeng; Hua Zhang; Jing Wang; Zhengrong Liang; Jianhua Ma
Journal:  Med Phys       Date:  2017-03       Impact factor: 4.071

8.  Deformable image registration with local rigidity constraints for cone-beam CT-guided spine surgery.

Authors:  S Reaungamornrat; A S Wang; A Uneri; Y Otake; A J Khanna; J H Siewerdsen
Journal:  Phys Med Biol       Date:  2014-06-17       Impact factor: 3.609

9.  Value of tomography in detecting breast masses and discriminating malign and benign lesions.

Authors:  Hatice Ayça Ata Korkmaz; Miraç İsmet Çakır; Eser Bulut; Sibel Kul
Journal:  Turk J Surg       Date:  2019-12-16

10.  Rapamycin and mTOR: a serendipitous discovery and implications for breast cancer.

Authors:  Belinda Seto
Journal:  Clin Transl Med       Date:  2012-11-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.