Literature DB >> 18561647

Tumor trailing strategy for intensity-modulated radiation therapy of moving targets.

Alexei Trofimov1, Christian Vrancic, Timothy C Y Chan, Gregory C Sharp, Thomas Bortfeld.   

Abstract

Internal organ motion during the course of radiation therapy of cancer affects the distribution of the delivered dose and, generally, reduces its conformality to the targeted volume. Previously proposed approaches aimed at mitigating the effect of internal motion in intensity-modulated radiation therapy (IMRT) included expansion of the target margins, motion-correlated delivery (e.g., respiratory gating, tumor tracking), and adaptive treatment plan optimization employing a probabilistic description of motion. We describe and test the tumor trailing strategy, which utilizes the synergy of motion-adaptive treatment planning and delivery methods. We regard the (rigid) target motion as a superposition of a relatively fast cyclic component (e.g., respiratory) and slow aperiodic trends (e.g., the drift of exhalation baseline). In the trailing approach, these two components of motion are decoupled and dealt with separately. Real-time motion monitoring is employed to identify the "slow" shifts, which are then corrected by applying setup adjustments. The delivery does not track the target position exactly, but trails the systematic trend due to the delay between the time a shift occurs, is reliably detected, and, subsequently, corrected. The "fast" cyclic motion is accounted for with a robust motion-adaptive treatment planning, which allows for variability in motion parameters (e.g., mean and extrema of the tidal volume, variable period of respiration, and expiratory duration). Motion-surrogate data from gated IMRT treatments were used to provide probability distribution data for motion-adaptive planning and to test algorithms that identified systematic trends in the character of motion. Sample IMRT fields were delivered on a clinical linear accelerator to a programmable moving phantom. Dose measurements were performed with a commercial two-dimensional ion-chamber array. The results indicate that by reducing intrafractional motion variability, the trailing strategy enhances relevance and applicability of motion-adaptive planning methods, and improves conformality of the delivered dose to the target in the presence of irregular motion. Trailing strategy can be applied to respiratory-gated treatments, in which the correction for the slow motion can increase the duty cycle, while robust probabilistic planning can improve management of the residual motion within the gate window. Similarly, trailing may improve the dose conformality in treatment of patients who exhibit detectable target motion of low amplitude, which is considered insufficient to provide a clinical indication for the use of respiratory-gated treatment (e.g., peak-to-peak motion of less than 10 mm). The mechanical limitations of implementing tumor trailing are less rigorous than those of real-time tracking, and the same technology could be used for both.

Entities:  

Mesh:

Year:  2008        PMID: 18561647      PMCID: PMC2809728          DOI: 10.1118/1.2900108

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  55 in total

Review 1.  Errors and margins in radiotherapy.

Authors:  Marcel van Herk
Journal:  Semin Radiat Oncol       Date:  2004-01       Impact factor: 5.934

2.  Effects of motion on the total dose distribution.

Authors:  Thomas Bortfeld; Steve B Jiang; Eike Rietzel
Journal:  Semin Radiat Oncol       Date:  2004-01       Impact factor: 5.934

Review 3.  4-dimensional computed tomography imaging and treatment planning.

Authors:  Paul Keall
Journal:  Semin Radiat Oncol       Date:  2004-01       Impact factor: 5.934

4.  A fluence convolution method to account for respiratory motion in three-dimensional dose calculations of the liver: a Monte Carlo study.

Authors:  Indrin J Chetty; Mihaela Rosu; Neelam Tyagi; Lon H Marsh; Daniel L McShan; James M Balter; Benedick A Fraass; Randall K Ten Haken
Journal:  Med Phys       Date:  2003-07       Impact factor: 4.071

5.  Treatment plan optimization incorporating respiratory motion.

Authors:  Tiezhi Zhang; Robert Jeraj; Harry Keller; Weiguo Lu; Gustavo H Olivera; Todd R McNutt; Thomas R Mackie; Bhudatt Paliwal
Journal:  Med Phys       Date:  2004-06       Impact factor: 4.071

6.  4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT.

Authors:  Tinsu Pan; Ting-Yim Lee; Eike Rietzel; George T Y Chen
Journal:  Med Phys       Date:  2004-02       Impact factor: 4.071

7.  Clinical experience using respiratory gated radiation therapy: comparison of free-breathing and breath-hold techniques.

Authors:  Anthony M Berson; Richard Emery; Lara Rodriguez; Gregory M Richards; Tracy Ng; Seema Sanghavi; Jean Barsa
Journal:  Int J Radiat Oncol Biol Phys       Date:  2004-10-01       Impact factor: 7.038

8.  A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing.

Authors:  Daniel A Low; Michelle Nystrom; Eugene Kalinin; Parag Parikh; James F Dempsey; Jeffrey D Bradley; Sasa Mutic; Sasha H Wahab; Tareque Islam; Gary Christensen; David G Politte; Bruce R Whiting
Journal:  Med Phys       Date:  2003-06       Impact factor: 4.071

9.  Application of real-time tumor-tracking and gated radiotherapy system for unresectable pancreatic cancer.

Authors:  Yong Chan Ahn; Shinichi Shimizu; Hiroki Shirato; Takayuki Hashimoto; Yasuhiro Osaka; Xiao Qing Zhang; Tatsuya Abe; Masao Hosokawa; Kazuo Miyasaka
Journal:  Yonsei Med J       Date:  2004-08-31       Impact factor: 2.759

10.  Correlation between the respiratory waveform measured using a respiratory sensor and 3D tumor motion in gated radiotherapy.

Authors:  Yoshikazu Tsunashima; Takeji Sakae; Yoshiyuki Shioyama; Kenji Kagei; Toshiyuki Terunuma; Akihiro Nohtomi; Yasuyuki Akine
Journal:  Int J Radiat Oncol Biol Phys       Date:  2004-11-01       Impact factor: 7.038

View more
  11 in total

1.  Use of dMLC for implementation of dynamic respiratory-gated radiation therapy.

Authors:  Eric W Pepin; Huanmei Wu; Hiroki Shirato
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

2.  Experimental investigation of a moving averaging algorithm for motion perpendicular to the leaf travel direction in dynamic MLC target tracking.

Authors:  Jai-Woong Yoon; Amit Sawant; Yelin Suh; Byung-Chul Cho; Tae-Suk Suh; Paul Keall
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

3.  Toward correcting drift in target position during radiotherapy via computer-controlled couch adjustments on a programmable Linac.

Authors:  Joseph E McNamara; Rajesh Regmi; D Michael Lovelock; Ellen D Yorke; Karyn A Goodman; Andreas Rimner; Hassan Mostafavi; Gig S Mageras
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

4.  Feasibility of automated pancreas segmentation based on dynamic MRI.

Authors:  S Gou; J Wu; F Liu; P Lee; S Rapacchi; P Hu; K Sheng
Journal:  Br J Radiol       Date:  2014-10-01       Impact factor: 3.039

5.  Marker-free lung tumor trajectory estimation from a cone beam CT sinogram.

Authors:  Geoffrey D Hugo; Jian Liang; Di Yan
Journal:  Phys Med Biol       Date:  2010-04-14       Impact factor: 3.609

6.  Potential underestimation of the internal target volume (ITV) from free-breathing CBCT.

Authors:  Irina Vergalasova; Jacqueline Maurer; Fang-Fang Yin
Journal:  Med Phys       Date:  2011-08       Impact factor: 4.071

7.  Management of three-dimensional intrafraction motion through real-time DMLC tracking.

Authors:  Amit Sawant; Raghu Venkat; Vikram Srivastava; David Carlson; Sergey Povzner; Herb Cattell; Paul Keall
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

Review 8.  Particle therapy of moving targets-the strategies for tumour motion monitoring and moving targets irradiation.

Authors:  Tomasz Kubiak
Journal:  Br J Radiol       Date:  2016-07-19       Impact factor: 3.039

9.  Markerless tumor tracking using short kilovoltage imaging arcs for lung image-guided radiotherapy.

Authors:  Chun-Chien Shieh; Paul J Keall; Zdenka Kuncic; Chen-Yu Huang; Ilana Feain
Journal:  Phys Med Biol       Date:  2015-11-19       Impact factor: 3.609

10.  Evaluation and commissioning of a surface based system for respiratory sensing in 4D CT.

Authors:  Maria Francesca Spadea; Guido Baroni; David P Gierga; Julie C Turcotte; George T Y Chen; Gregory C Sharp
Journal:  J Appl Clin Med Phys       Date:  2010-12-04       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.