Literature DB >> 15465214

Correlation between the respiratory waveform measured using a respiratory sensor and 3D tumor motion in gated radiotherapy.

Yoshikazu Tsunashima1, Takeji Sakae, Yoshiyuki Shioyama, Kenji Kagei, Toshiyuki Terunuma, Akihiro Nohtomi, Yasuyuki Akine.   

Abstract

PURPOSE: The purpose of this study is to investigate the correlation between the respiratory waveform measured using a respiratory sensor and three-dimensional (3D) tumor motion. METHODS AND MATERIALS: A laser displacement sensor (LDS: KEYENCE LB-300) that measures distance using infrared light was used as the respiratory sensor. This was placed such that the focus was in an area around the patient's navel. When the distance from the LDS to the body surface changes as the patient breathes, the displacement is detected as a respiratory waveform. To obtain the 3D tumor motion, a biplane digital radiography unit was used. For the tumor in the lung, liver, and esophagus of 26 patients, the waveform was compared with the 3D tumor motion. The relationship between the respiratory waveform and the 3D tumor motion was analyzed by means of the Fourier transform and a cross-correlation function.
RESULTS: The respiratory waveform cycle agreed with that of the cranial-caudal and dorsal-ventral tumor motion. A phase shift observed between the respiratory waveform and the 3D tumor motion was principally in the range 0.0 to 0.3 s, regardless of the organ being measured, which means that the respiratory waveform does not always express the 3D tumor motion with fidelity. For this reason, the standard deviation of the tumor position in the expiration phase, as indicated by the respiratory waveform, was derived, which should be helpful in suggesting the internal margin required in the case of respiratory gated radiotherapy.
CONCLUSION: Although obtained from only a few breathing cycles for each patient, the correlation between the respiratory waveform and the 3D tumor motion was evident in this study. If this relationship is analyzed carefully and an internal margin is applied, the accuracy and convenience of respiratory gated radiotherapy could be improved by use of the respiratory sensor.Thus, it is expected that this procedure will come into wider use.

Entities:  

Mesh:

Year:  2004        PMID: 15465214     DOI: 10.1016/j.ijrobp.2004.06.026

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  43 in total

1.  Static versus prospective gated non-breath hold volumetric MDCT imaging of the lungs.

Authors:  Osama I Saba; Deokiee Chon; Kenneth Beck; Geoffrey McLennan; Jered Sieren; Joseph Reinhardt; Eric A Hoffman
Journal:  Acad Radiol       Date:  2005-11       Impact factor: 3.173

2.  Experimental verification of the utility of positron emitter nuclei generated by photonuclear reactions for X-ray beam monitoring in a phantom.

Authors:  Teiji Nishio; Taku Inaniwa; Kazumasa Inoue; Aya Miyatake; Keiichi Nakagawa; Kiyoshi Yoda; Takashi Ogino
Journal:  Radiat Med       Date:  2007-12-25

3.  Esophagus and spinal cord motion relative to GTV motion in four-dimensional CTs of lung cancer patients.

Authors:  Elisabeth Weiss; Krishni Wijesooriya; Paul Keall
Journal:  Radiother Oncol       Date:  2008-02-21       Impact factor: 6.280

4.  Technical note: Correlation of respiratory motion between external patient surface and internal anatomical landmarks.

Authors:  Hadi Fayad; Tinsu Pan; Jean François Clement; Dimitris Visvikis
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

5.  Factors affecting the accuracy of respiratory tracking of the image-guided robotic radiosurgery system.

Authors:  Mitsuhiro Inoue; Kohei Okawa; Junichi Taguchi; Yoshifumi Hirota; Yohei Yanagiya; Chie Kikuchi; Michio Iwabuchi; Taro Murai; Hiromitsu Iwata; Hiroya Shiomi; Izumi Koike; Koshi Tatewaki; Seiji Ohta
Journal:  Jpn J Radiol       Date:  2019-07-31       Impact factor: 2.374

6.  Higher-order singular value decomposition-based lung parcellation for breathing motion management.

Authors:  Samadrita Roy Chowdhury; Joyita Dutta
Journal:  J Med Imaging (Bellingham)       Date:  2019-05-03

Review 7.  Proton Beam Therapy for Hepatocellular Carcinoma: A Review of the University of Tsukuba Experience.

Authors:  Masashi Mizumoto; Yoshiko Oshiro; Toshiyuki Okumura; Nobuyoshi Fukumitsu; Haruko Numajiri; Kayoko Ohnishi; Teruhito Aihara; Hitoshi Ishikawa; Koji Tsuboi; Hideyuki Sakurai
Journal:  Int J Part Ther       Date:  2016-03-24

8.  Effects of audio coaching and visual feedback on the stability of respiration during radiotherapy.

Authors:  Fumiya Baba; Satoshi Tanaka; Yoshinori Nonogaki; Shinji Hasegawa; Minami Nishihashi; Shiho Ayakawa; Maho Yamada; Yuta Shibamoto
Journal:  Jpn J Radiol       Date:  2016-06-17       Impact factor: 2.374

9.  Tumor trailing strategy for intensity-modulated radiation therapy of moving targets.

Authors:  Alexei Trofimov; Christian Vrancic; Timothy C Y Chan; Gregory C Sharp; Thomas Bortfeld
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

10.  Technical considerations for noncoplanar proton-beam therapy of patients with tumors proximal to the optic nerve.

Authors:  Masashi Mizumoto; Hidetsugu Nakayama; Mari Tokita; Shinji Sugahara; Haruko Hashii; Takeji Sakae; Koji Tsuboi; Hideyuki Sakurai; Koichi Tokuuye
Journal:  Strahlenther Onkol       Date:  2009-12-28       Impact factor: 3.621

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.