Literature DB >> 18561681

Management of three-dimensional intrafraction motion through real-time DMLC tracking.

Amit Sawant1, Raghu Venkat, Vikram Srivastava, David Carlson, Sergey Povzner, Herb Cattell, Paul Keall.   

Abstract

Tumor tracking using a dynamic multileaf collimator (DMLC) represents a promising approach for intrafraction motion management in thoracic and abdominal cancer radiotherapy. In this work, we develop, empirically demonstrate, and characterize a novel 3D tracking algorithm for real-time, conformal, intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT)-based radiation delivery to targets moving in three dimensions. The algorithm obtains real-time information of target location from an independent position monitoring system and dynamically calculates MLC leaf positions to account for changes in target position. Initial studies were performed to evaluate the geometric accuracy of DMLC tracking of 3D target motion. In addition, dosimetric studies were performed on a clinical linac to evaluate the impact of real-time DMLC tracking for conformal, step-and-shoot (S-IMRT), dynamic (D-IMRT), and VMAT deliveries to a moving target. The efficiency of conformal and IMRT delivery in the presence of tracking was determined. Results show that submillimeter geometric accuracy in all three dimensions is achievable with DMLC tracking. Significant dosimetric improvements were observed in the presence of tracking for conformal and IMRT deliveries to moving targets. A gamma index evaluation with a 3%-3 mm criterion showed that deliveries without DMLC tracking exhibit between 1.7 (S-IMRT) and 4.8 (D-IMRT) times more dose points that fail the evaluation compared to corresponding deliveries with tracking. The efficiency of IMRT delivery, as measured in the lab, was observed to be significantly lower in case of tracking target motion perpendicular to MLC leaf travel compared to motion parallel to leaf travel. Nevertheless, these early results indicate that accurate, real-time DMLC tracking of 3D tumor motion is feasible and can potentially result in significant geometric and dosimetric advantages leading to more effective management of intrafraction motion.

Entities:  

Mesh:

Year:  2008        PMID: 18561681      PMCID: PMC2809733          DOI: 10.1118/1.2905355

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  50 in total

1.  The use of active breathing control (ABC) to reduce margin for breathing motion.

Authors:  J W Wong; M B Sharpe; D A Jaffray; V R Kini; J M Robertson; J S Stromberg; A A Martinez
Journal:  Int J Radiat Oncol Biol Phys       Date:  1999-07-01       Impact factor: 7.038

2.  Respiratory gating for liver tumors: use in dose escalation.

Authors:  Raquel Wagman; Ellen Yorke; Eric Ford; Philippe Giraud; Gikas Mageras; Bruce Minsky; Kenneth Rosenzweig
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-03-01       Impact factor: 7.038

3.  Stereotactic body radiation therapy of early-stage non-small-cell lung carcinoma: phase I study.

Authors:  Ronald C McGarry; Lech Papiez; Mark Williams; Tia Whitford; Robert D Timmerman
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-08-22       Impact factor: 7.038

4.  Geometric accuracy of a real-time target tracking system with dynamic multileaf collimator tracking system.

Authors:  Paul J Keall; Herbert Cattell; Damodar Pokhrel; Sonja Dieterich; Kenneth H Wong; Martin J Murphy; S Sastry Vedam; Krishni Wijesooriya; Radhe Mohan
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-08-01       Impact factor: 7.038

5.  The correlation evaluation of a tumor tracking system using multiple external markers.

Authors:  Hui Yan; Fang-Fang Yin; Guo-Pei Zhu; Munther Ajlouni; Jae Ho Kim
Journal:  Med Phys       Date:  2006-11       Impact factor: 4.071

6.  Intensity modulation with respiratory gating for radiotherapy of the pleural space.

Authors:  Raef S Ahmed; Sui Shen; Roger Ove; Jun Duan; John B Fiveash; Suzanne M Russo
Journal:  Med Dosim       Date:  2007       Impact factor: 1.482

7.  Tracking 'differential organ motion' with a 'breathing' multileaf collimator: magnitude of problem assessed using 4D CT data and a motion-compensation strategy.

Authors:  J R McClelland; S Webb; D McQuaid; D M Binnie; D J Hawkes
Journal:  Phys Med Biol       Date:  2007-07-24       Impact factor: 3.609

8.  Volumetric modulated arc therapy: IMRT in a single gantry arc.

Authors:  Karl Otto
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

9.  Evaluation of respiratory movement during gated radiotherapy using film and electronic portal imaging.

Authors:  E C Ford; G S Mageras; E Yorke; K E Rosenzweig; R Wagman; C C Ling
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-02-01       Impact factor: 7.038

10.  Intrafraction prostate motion during IMRT for prostate cancer.

Authors:  Eugene Huang; Lei Dong; Anurag Chandra; Deborah A Kuban; Isaac I Rosen; Anissa Evans; Alan Pollack
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-06-01       Impact factor: 7.038

View more
  55 in total

1.  Image-based dynamic multileaf collimator tracking of moving targets during intensity-modulated arc therapy.

Authors:  Per Rugaard Poulsen; Walther Fledelius; Byungchul Cho; Paul Keall
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-03-06       Impact factor: 7.038

2.  The dosimetric impact of inversely optimized arc radiotherapy plan modulation for real-time dynamic MLC tracking delivery.

Authors:  Marianne Falk; Tobias Larsson; Paul Keall; Byung Chul Cho; Marianne Aznar; Stine Korreman; Per Poulsen; Per Munck Af Rosenschold
Journal:  Med Phys       Date:  2012-03       Impact factor: 4.071

3.  Verification of MLC based real-time tumor tracking using an electronic portal imaging device.

Authors:  Sarah Han-Oh; Byong Yong Yi; Fritz Lerma; Barry L Berman; Minzhi Gui; Cedric Yu
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

4.  Detailed analysis of latencies in image-based dynamic MLC tracking.

Authors:  Per Rugaard Poulsen; Byungchul Cho; Amit Sawant; Dan Ruan; Paul J Keall
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

5.  The impact of leaf width and plan complexity on DMLC tracking of prostate intensity modulated arc therapy.

Authors:  Tobias Pommer; Marianne Falk; Per Rugaard Poulsen; Paul J Keall; Ricky T O'Brien; Per Munck af Rosenschöld
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

6.  Time-resolved dose distributions to moving targets during volumetric modulated arc therapy with and without dynamic MLC tracking.

Authors:  Thomas Ravkilde; Paul J Keall; Cai Grau; Morten Høyer; Per R Poulsen
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

7.  Radio frequency noise from an MLC: a feasibility study of the use of an MLC for linac-MR systems.

Authors:  M Lamey; J Yun; B Burke; S Rathee; B G Fallone
Journal:  Phys Med Biol       Date:  2010-01-20       Impact factor: 3.609

8.  Experimental investigation of a general real-time 3D target localization method using sequential kV imaging combined with respiratory monitoring.

Authors:  Byungchul Cho; Per Poulsen; Dan Ruan; Amit Sawant; Paul J Keall
Journal:  Phys Med Biol       Date:  2012-10-24       Impact factor: 3.609

9.  Dosimetric benefit of DMLC tracking for conventional and sub-volume boosted prostate intensity-modulated arc radiotherapy.

Authors:  Tobias Pommer; Marianne Falk; Per R Poulsen; Paul J Keall; Ricky T O'Brien; Peter Meidahl Petersen; Per Munck af Rosenschöld
Journal:  Phys Med Biol       Date:  2013-03-14       Impact factor: 3.609

10.  Real-time dynamic MLC tracking for inversely optimized arc radiotherapy.

Authors:  Marianne Falk; Per Munck af Rosenschöld; Paul Keall; Herbert Cattell; Byung Chul Cho; Per Poulsen; Sergey Povzner; Amit Sawant; Jens Zimmerman; Stine Korreman
Journal:  Radiother Oncol       Date:  2010-01-19       Impact factor: 6.280

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.