Literature DB >> 18560046

An analysis of thoracic and abdominal tumour motion for stereotactic body radiotherapy patients.

Yelin Suh1, Sonja Dieterich, Byungchul Cho, Paul J Keall.   

Abstract

An analysis of thoracic and abdominal tumour motion for stereotactic body radiotherapy patients was performed using more than 70 h of tumour motion estimated from the correlation between the external and internal motion for 143 treatment fractions in 42 patients. The tumour sites included lungs (30 patients) and retroperitoneum (12 patients). The overall mean respiratory-induced peak-to-trough distance was 0.48 cm, with individual treatment fraction means ranging from 0.02 to 1.44 cm. The overall mean respiratory period was 3.8 s, with individual treatment fraction means ranging from 2.2 to 6.4 s. In 57 treatment fractions (40%), the mean respiratory-induced peak-to-trough distance was greater than 0.5 cm. In general, tumour motion was predominantly superior-inferior (60% of all the treatment fractions), while anterior-posterior and left-right motion were 22% and 18%, respectively. The motion was predominantly linear, and the overall mean of the first principal component was 94%. However, for motion magnitude, direction and linearity, large variations were observed from patient to patient, fraction to fraction and cycle to cycle.

Entities:  

Mesh:

Year:  2008        PMID: 18560046     DOI: 10.1088/0031-9155/53/13/016

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  55 in total

1.  Image-based dynamic multileaf collimator tracking of moving targets during intensity-modulated arc therapy.

Authors:  Per Rugaard Poulsen; Walther Fledelius; Byungchul Cho; Paul Keall
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-03-06       Impact factor: 7.038

2.  Feasibility of low-dose single-view 3D fiducial tracking concurrent with external beam delivery.

Authors:  Michael A Speidel; Brian P Wilfley; Annie Hsu; Dimitre Hristov
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

3.  Time-resolved dose distributions to moving targets during volumetric modulated arc therapy with and without dynamic MLC tracking.

Authors:  Thomas Ravkilde; Paul J Keall; Cai Grau; Morten Høyer; Per R Poulsen
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

4.  Characterizing spatiotemporal information loss in sparse-sampling-based dynamic MRI for monitoring respiration-induced tumor motion in radiotherapy.

Authors:  Tatsuya J Arai; Joris Nofiele; Ananth J Madhuranthakam; Qing Yuan; Ivan Pedrosa; Rajiv Chopra; Amit Sawant
Journal:  Med Phys       Date:  2016-06       Impact factor: 4.071

5.  Failure mode and effect analysis-based quality assurance for dynamic MLC tracking systems.

Authors:  Amit Sawant; Sonja Dieterich; Michelle Svatos; Paul Keall
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

6.  Experimental investigation of a moving averaging algorithm for motion perpendicular to the leaf travel direction in dynamic MLC target tracking.

Authors:  Jai-Woong Yoon; Amit Sawant; Yelin Suh; Byung-Chul Cho; Tae-Suk Suh; Paul Keall
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

7.  An externally and internally deformable, programmable lung motion phantom.

Authors:  Yam Cheung; Amit Sawant
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

8.  Mitigating errors in external respiratory surrogate-based models of tumor position.

Authors:  Kathleen T Malinowski; Thomas J McAvoy; Rohini George; Sonja Dieterich; Warren D D'Souza
Journal:  Int J Radiat Oncol Biol Phys       Date:  2012-04-01       Impact factor: 7.038

9.  Experimental investigation of a general real-time 3D target localization method using sequential kV imaging combined with respiratory monitoring.

Authors:  Byungchul Cho; Per Poulsen; Dan Ruan; Amit Sawant; Paul J Keall
Journal:  Phys Med Biol       Date:  2012-10-24       Impact factor: 3.609

10.  Accuracy in the localization of thoracic and abdominal tumors using respiratory displacement, velocity, and phase.

Authors:  U W Langner; P J Keall
Journal:  Med Phys       Date:  2009-02       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.