Mitigating errors in external respiratory surrogate-based models of tumor position.

Kathleen T Malinowski1, Thomas J McAvoy, Rohini George, Sonja Dieterich, Warren D D'Souza.   

Abstract

PURPOSE: To investigate the effect of tumor site, measurement precision, tumor-surrogate correlation, training data selection, model design, and interpatient and interfraction variations on the accuracy of external marker-based models of tumor position. METHODS AND MATERIALS: Cyberknife Synchrony system log files comprising synchronously acquired positions of external markers and the tumor from 167 treatment fractions were analyzed. The accuracy of Synchrony, ordinary-least-squares regression, and partial-least-squares regression models for predicting the tumor position from the external markers was evaluated. The quantity and timing of the data used to build the predictive model were varied. The effects of tumor-surrogate correlation and the precision in both the tumor and the external surrogate position measurements were explored by adding noise to the data.
RESULTS: The tumor position prediction errors increased during the duration of a fraction. Increasing the training data quantities did not always lead to more accurate models. Adding uncorrelated noise to the external marker-based inputs degraded the tumor-surrogate correlation models by 16% for partial-least-squares and 57% for ordinary-least-squares. External marker and tumor position measurement errors led to tumor position prediction changes 0.3-3.6 times the magnitude of the measurement errors, varying widely with model algorithm. The tumor position prediction errors were significantly associated with the patient index but not with the fraction index or tumor site. Partial-least-squares was as accurate as Synchrony and more accurate than ordinary-least-squares.
CONCLUSIONS: The accuracy of surrogate-based inferential models of tumor position was affected by all the investigated factors, except for the tumor site and fraction index. Copyright Â
© 2012 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22429333      PMCID: PMC3346954          DOI: 10.1016/j.ijrobp.2011.05.042

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  28 in total

1.  Issues in respiratory motion compensation during external-beam radiotherapy.

Authors:  Cihat Ozhasoglu; Martin J Murphy
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-04-01       Impact factor: 7.038

2.  Quantitation of respiratory motion during 4D-PET/CT acquisition.

Authors:  S A Nehmeh; Y E Erdi; T Pan; E Yorke; G S Mageras; K E Rosenzweig; H Schoder; H Mostafavi; O Squire; A Pevsner; S M Larson; J L Humm
Journal:  Med Phys       Date:  2004-06       Impact factor: 4.071

3.  The correlation between internal and external markers for abdominal tumors: implications for respiratory gating.

Authors:  David P Gierga; Johanna Brewer; Gregory C Sharp; Margrit Betke; Christopher G Willett; George T Y Chen
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-04-01       Impact factor: 7.038

4.  Determining parameters for respiration-gated radiotherapy.

Authors:  S S Vedam; P J Keall; V R Kini; R Mohan
Journal:  Med Phys       Date:  2001-10       Impact factor: 4.071

5.  Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor.

Authors:  H Shirato; S Shimizu; K Kitamura; T Nishioka; K Kagei; S Hashimoto; H Aoyama; T Kunieda; N Shinohara; H Dosaka-Akita; K Miyasaka
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-09-01       Impact factor: 7.038

6.  Commissioning an image-guided localization system for radiotherapy.

Authors:  M H Phillips; K Singer; E Miller; K Stelzer
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-08-01       Impact factor: 7.038

7.  Image localization for frameless stereotactic radiotherapy.

Authors:  S L Meeks; F J Bova; T H Wagner; J M Buatti; W A Friedman; K D Foote
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-03-15       Impact factor: 7.038

8.  Correlation of lung tumor motion with external surrogate indicators of respiration.

Authors:  Jeremy D P Hoisak; Katharina E Sixel; Romeo Tirona; Patrick C F Cheung; Jean-Philippe Pignol
Journal:  Int J Radiat Oncol Biol Phys       Date:  2004-11-15       Impact factor: 7.038

9.  Residual motion of lung tumours in gated radiotherapy with external respiratory surrogates.

Authors:  Ross I Berbeco; Seiko Nishioka; Hiroki Shirato; George T Y Chen; Steve B Jiang
Journal:  Phys Med Biol       Date:  2005-07-28       Impact factor: 3.609

10.  Quantifying the predictability of diaphragm motion during respiration with a noninvasive external marker.

Authors:  S S Vedam; V R Kini; P J Keall; V Ramakrishnan; H Mostafavi; R Mohan
Journal:  Med Phys       Date:  2003-04       Impact factor: 4.071

View more
  7 in total

1.  Online monitoring and error detection of real-time tumor displacement prediction accuracy using control limits on respiratory surrogate statistics.

Authors:  Kathleen Malinowski; Thomas J McAvoy; Rohini George; Sonja Dieterich; Warren D D'Souza
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

2.  Breathing-motion-compensated robotic guided stereotactic body radiation therapy : Patterns of failure analysis.

Authors:  Susanne Stera; Panagiotis Balermpas; Mark K H Chan; Stefan Huttenlocher; Stefan Wurster; Christian Keller; Detlef Imhoff; Dirk Rades; Jürgen Dunst; Claus Rödel; Guido Hildebrandt; Oliver Blanck
Journal:  Strahlenther Onkol       Date:  2017-09-05       Impact factor: 3.621

3.  Maintaining tumor targeting accuracy in real-time motion compensation systems for respiration-induced tumor motion.

Authors:  Kathleen Malinowski; Thomas J McAvoy; Rohini George; Sonja Dieterich; Warren D D'Souza
Journal:  Med Phys       Date:  2013-07       Impact factor: 4.071

4.  Retrospective assessment of a single fiducial marker tracking regimen with robotic stereotactic body radiation therapy for liver tumours.

Authors:  Masao Nakayama; Kazuyuki Uehara; Hideki Nishimura; Shuhei Tamura; Yoshiki Munetomo; Shinji Tsudou; Hiroshi Mayahara; Naritoshi Mukumoto; Moshi Geso; Ryohei Sasaki
Journal:  Rep Pract Oncol Radiother       Date:  2019-06-21

Review 5.  The potential role of respiratory motion management and image guidance in the reduction of severe toxicities following stereotactic ablative radiation therapy for patients with centrally located early stage non-small cell lung cancer or lung metastases.

Authors:  Alexander Chi; Nam Phong Nguyen; Ritsuko Komaki
Journal:  Front Oncol       Date:  2014-06-25       Impact factor: 6.244

6.  Evaluation of tracking accuracy of the CyberKnife system using a webcam and printed calibrated grid.

Authors:  Iori Sumida; Hiroya Shiomi; Naokazu Higashinaka; Yoshikazu Murashima; Youichi Miyamoto; Hideya Yamazaki; Nobuhisa Mabuchi; Eimei Tsuda; Kazuhiko Ogawa
Journal:  J Appl Clin Med Phys       Date:  2016-03-08       Impact factor: 2.102

7.  Image quality of 4D in-treatment CBCT acquired during lung SBRT using FFF beam: a phantom study.

Authors:  Jihun Kim; Ki Chang Keum; Ho Lee; Chae-Seon Hong; Kwangwoo Park; Jin Sung Kim
Journal:  Radiat Oncol       Date:  2020-09-25       Impact factor: 3.481

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.