Literature DB >> 18509638

Multicentre use of a porous tantalum monoblock acetabular component.

Th A Xenakis1, G A Macheras, K S Stafilas, A T Kostakos, K Bargiotas, K N Malizos.   

Abstract

The purpose of this study was to evaluate the minimum five-year prospective results from the multicentre use of a porous tantalum monoblock acetabular component for primary total hip arthroplasty (THA). A multicentre study was performed in 253 consecutive primary THAs in three separate surgical centres. All patients underwent identical postoperative protocols including radiological and clinical evaluation. The average preoperative total HHS score was 44.0 +/- 13.8 and increased at one-year follow-up to 95.2 +/- 4.8 (p <0.05), remaining constant through the five-year follow-up at 97.0 +/- 6.2 (p < 0.05). There was no radiographic evidence of gross polyethylene wear, progressive radiolucencies, osteolytic lesions, acetabular fracture, or component subsidence. From these results, we can recommend the continued use of this material for acetabular components in primary THA and that further review of the current multicentre population is warranted to determine the long-term durability of the acetabular composite.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18509638      PMCID: PMC2898972          DOI: 10.1007/s00264-008-0581-4

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  25 in total

1.  Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial.

Authors:  J D Bobyn; G J Stackpool; S A Hacking; M Tanzer; J J Krygier
Journal:  J Bone Joint Surg Br       Date:  1999-09

Review 2.  A porous tantalum trabecular metal: basic science.

Authors:  Robert Cohen
Journal:  Am J Orthop (Belle Mead NJ)       Date:  2002-04

3.  Tissue response to porous tantalum acetabular cups: a canine model.

Authors:  J D Bobyn; K K Toh; S A Hacking; M Tanzer; J J Krygier
Journal:  J Arthroplasty       Date:  1999-04       Impact factor: 4.757

4.  Evaluation of the design and clinical performance of cementless acetabular components.

Authors:  D A Fisher; T H Mallory; T J Kraus; M B Mitchell
Journal:  Semin Arthroplasty       Date:  1990-07

5.  Porous-coated acetabular components with screw fixation. Five to ten-year results.

Authors:  H A Latimer; P F Lachiewicz
Journal:  J Bone Joint Surg Am       Date:  1996-07       Impact factor: 5.284

6.  Limb salvage and abductor reattachment using a custom prosthesis with porous tantalum components.

Authors:  Brian Chalkin; Jon Minter
Journal:  J Arthroplasty       Date:  2005-01       Impact factor: 4.757

7.  Middle-term results of threaded acetabular cups. High failure rates five years after surgery.

Authors:  H G Simank; D R Brocai; D Reiser; M Thomsen; D Sabo; M Lukoschek
Journal:  J Bone Joint Surg Br       Date:  1997-05

8.  EBRA: a method to measure migration of acetabular components.

Authors:  M Krismer; R Bauer; J Tschupik; P Mayrhofer
Journal:  J Biomech       Date:  1995-10       Impact factor: 2.712

9.  The relationship between cup design and the radiological signs of aseptic loosening in total hip arthroplasty.

Authors:  U Müller; E Gautier; C Roeder; A Busato
Journal:  J Bone Joint Surg Br       Date:  2003-01

10.  Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty.

Authors:  D H Sochart
Journal:  Clin Orthop Relat Res       Date:  1999-06       Impact factor: 4.176

View more
  6 in total

1.  Radiostereometric analysis study of tantalum compared with titanium acetabular cups and highly cross-linked compared with conventional liners in young patients undergoing total hip replacement.

Authors:  David C Ayers; Meridith Greene; Benjamin Snyder; Michelle Aubin; Jacob Drew; Charles Bragdon
Journal:  J Bone Joint Surg Am       Date:  2015-04-15       Impact factor: 5.284

Review 2.  Properties of open-cell porous metals and alloys for orthopaedic applications.

Authors:  Gladius Lewis
Journal:  J Mater Sci Mater Med       Date:  2013-07-13       Impact factor: 3.896

3.  Smoking may be a harbinger of early failure with ultraporous metal acetabular reconstruction.

Authors:  Adolph V Lombardi; Keith R Berend; Joanne B Adams; Ryan C Jefferson; Michael A Sneller
Journal:  Clin Orthop Relat Res       Date:  2013-02       Impact factor: 4.176

4.  A monoblock porous tantalum acetabular cup has no osteolysis on CT at 10 years.

Authors:  Todd C Moen; Raju Ghate; Noel Salaz; Jason Ghodasra; S David Stulberg
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

5.  Bone ingrowth in well-fixed retrieved porous tantalum implants.

Authors:  Josa A Hanzlik; Judd S Day
Journal:  J Arthroplasty       Date:  2013-03-18       Impact factor: 4.757

6.  Comparison of trabecular metal cups and titanium fiber-mesh cups in primary hip arthroplasty: a randomized RSA and bone mineral densitometry study of 50 hips.

Authors:  Thomas Baad-Hansen; Søren Kold; Poul Torben Nielsen; Mogens Berg Laursen; Poul Hedevang Christensen; Kjeld Soballe
Journal:  Acta Orthop       Date:  2011-03-25       Impact factor: 3.717

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.