Porous-coated acetabular components with screw fixation. Five to ten-year results.

H A Latimer1, P F Lachiewicz.   

Abstract

The results of 136 consecutive primary total hip arthroplasties performed by one surgeon with the Harris-Galante-I porous-coated acetabular component were reviewed at a mean of seven years (range, five to ten years). In all hips, the outer diameter of the acetabular component was the same as the diameter of the final reamer used in the preparation of the acetabulum. However, this reamer was used only briefly at the rim of the acetabulum, and therefore the components had so-called press-fit stability. A mean of four screws (range, three to six screws) were used for additional fixation of the component. The clinical evaluation was performed with use of the Harris hip score. Standardized anteroposterior radiographs of the pelvis were assessed for migration of the component, radiolucent and radiodense lines, linear wear of the polyethylene, and osteolysis. No acetabular component had been revised for loosening and none were radiographically loose at the time of the most recent follow-up evaluation. There were no complications related to the use of the screws, and no screw had bent or broken. A non-progressive radiolucent line was seen in one acetabular zone in thirty-four hips (25 per cent) and in two acetabular zones in six hips (4 per cent). No hip had a radiolucent line in all three acetabular zones. The mean rate of linear wear of the polyethylene was 0.1 millimeter per year. There was no dissociation of the acetabular liner from the metal shell. Two hips (1 per cent) had asymptomatic osteolysis in the ischium and adjacent to the rim of the acetabular component; this was treated with grafting at the site of the lesion and exchange of the femoral head and the worn polyethylene liner. Five femoral components inserted without cement and one inserted with cement were revised because of loosening. The data suggest that, at a mean of seven years, fixation of this porous-coated component was uniformly excellent. The low prevalence of radiolucent lines and the absence of loosening are probably related, in part, to the technique of implantation. The low prevalence of polyethylene wear and pelvic osteolysis is a notable improvement compared with the results of arthroplasty with other porous-coated acetabular components. Although the results of the present study are encouraging, longer follow-up is necessary to determine the prevalence of late loosening and osteolysis.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8698733     DOI: 10.2106/00004623-199607000-00001

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  29 in total

1.  How long should patients be followed-up after total hip replacement? Current practice in the UK.

Authors:  M J Bankes; R Coull; B D Ferris
Journal:  Ann R Coll Surg Engl       Date:  1999-09       Impact factor: 1.891

2.  Acetabular component positioning using anatomic landmarks of the acetabulum.

Authors:  Yong-Chan Ha; Jeong Joon Yoo; Young-Kyun Lee; Jin Young Kim; Kyung-Hoi Koo
Journal:  Clin Orthop Relat Res       Date:  2012-07-10       Impact factor: 4.176

3.  Total hip arthroplasty performed in patients with residual poliomyelitis: does it work?

Authors:  Byung-Ho Yoon; Young-Kyun Lee; Jeong Joon Yoo; Hee Joong Kim; Kyung-Hoi Koo
Journal:  Clin Orthop Relat Res       Date:  2013-11-08       Impact factor: 4.176

4.  Multicentre use of a porous tantalum monoblock acetabular component.

Authors:  Th A Xenakis; G A Macheras; K S Stafilas; A T Kostakos; K Bargiotas; K N Malizos
Journal:  Int Orthop       Date:  2008-05-29       Impact factor: 3.075

5.  Ten-year results with the Morscher press-fit cup: an uncemented, non-modular, porous-coated cup inserted without screws.

Authors:  Guido Garavaglia; Anne Lübbeke; Christophe Barea; Constantinos Roussos; Robin Peter; Pierre Hoffmeyer
Journal:  Int Orthop       Date:  2010-06-04       Impact factor: 3.075

6.  Accumulation of fatty marrow in the osteonecrotic hip mimicking joint infection.

Authors:  Tae-Young Kim; Sun-Joo Kim; Young-Kyun Lee; Kyung-Hoi Koo
Journal:  Clin Orthop Relat Res       Date:  2011-08-31       Impact factor: 4.176

7.  Second-generation modular acetabular components provide fixation at 10 to 16 years.

Authors:  Paul F Lachiewicz; Elizabeth S Soileau
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

8.  Clinical and radiological results of hydroxyapatite-coated acetabular cups.

Authors:  J Blacha; J Gagała
Journal:  Int Orthop       Date:  2004-08-14       Impact factor: 3.075

9.  Trochanter/calcar preserving reconstruction in tumors involving the femoral head and neck.

Authors:  Hwan Seong Cho; Young-Kyun Lee; Yong-Chan Ha; Kyung-Hoi Koo
Journal:  World J Orthop       Date:  2016-07-18

10.  Survivorship of monoblock trabecular metal cups in primary THA : midterm results.

Authors:  Konstantinos N Malizos; Konstantinos Bargiotas; Loukia Papatheodorou; Michael Hantes; Theofilos Karachalios
Journal:  Clin Orthop Relat Res       Date:  2008-01-03       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.