Literature DB >> 20809172

A monoblock porous tantalum acetabular cup has no osteolysis on CT at 10 years.

Todd C Moen1, Raju Ghate, Noel Salaz, Jason Ghodasra, S David Stulberg.   

Abstract

BACKGROUND: Aseptic osteolysis has been the single most important factor limiting the longevity of a THA. A great deal of attention has been focused on the development of implants and materials that minimize the development of osteolysis. The monoblock porous tantalum acetabular cup was designed to minimize osteolysis, but whether it does so is unclear. QUESTIONS/PURPOSES: We evaluated the incidence of osteolytic lesions after THA using a monoblock porous tantalum acetabular component.
METHODS: We retrospectively reviewed 51 patients who had a THA using a monoblock porous tantalum acetabular cup. At a minimum of 9.6 years postoperatively (average, 10.3 years; SD, 0.2 years; range, 9.6-10.8 years), a helical CT scan of the pelvis using a metal suppression protocol was obtained. This scan was evaluated for the presence of osteolysis.
RESULTS: We found no evidence of osteolysis on CT scan at an average of 10.3 years.
CONCLUSIONS: Osteolysis appears not to be a major problem at 10 years with this monoblock porous tantalum acetabular component, but longer term followup will be required to determine whether these findings persist. LEVEL OF EVIDENCE: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 20809172      PMCID: PMC3018208          DOI: 10.1007/s11999-010-1500-8

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  38 in total

1.  Monitoring pelvic osteolysis following total hip replacement surgery: an algorithm for surveillance.

Authors:  S David Stulberg; Richard L Wixson; Angela D Adams; Ronald W Hendrix; Jeffrey B Bernfield
Journal:  J Bone Joint Surg Am       Date:  2002       Impact factor: 5.284

2.  Underestimation of pelvic osteolysis: the value of the iliac oblique radiograph.

Authors:  R H Zimlich; T K Fehring
Journal:  J Arthroplasty       Date:  2000-09       Impact factor: 4.757

3.  The acetabular component: an elliptical monoblock alternative.

Authors:  Thomas P Sculco
Journal:  J Arthroplasty       Date:  2002-06       Impact factor: 4.757

Review 4.  Mechanisms of failure of total hip replacements: lessons learned from retrieval studies.

Authors:  Kazuo Hirakawa; Joshua J Jacobs; Robert Urban; Tomoyuki Saito
Journal:  Clin Orthop Relat Res       Date:  2004-03       Impact factor: 4.176

5.  Bone remodeling around porous metal cementless acetabular components.

Authors:  R Michael Meneghini; Kerry S Ford; Cynthia H McCollough; Arlen D Hanssen; David G Lewallen
Journal:  J Arthroplasty       Date:  2009-05-26       Impact factor: 4.757

Review 6.  Clinical applications of Trabecular Metal.

Authors:  Michael J Christie
Journal:  Am J Orthop (Belle Mead NJ)       Date:  2002-04

7.  Use of helical computed tomography for the assessment of acetabular osteolysis after total hip arthroplasty.

Authors:  Lalit Puri; Richard L Wixson; Steven H Stern; Joe Kohli; Ronald W Hendrix; S David Stulberg
Journal:  J Bone Joint Surg Am       Date:  2002-04       Impact factor: 5.284

8.  Polyethylene wear in total hip arthroplasty in patient-matched groups. A comparison of stainless steel, cobalt chrome, and titanium-bearing surfaces.

Authors:  A B Bankston; P M Faris; E M Keating; M A Ritter
Journal:  J Arthroplasty       Date:  1993-06       Impact factor: 4.757

9.  Computed tomography to assess pelvic lysis after total hip replacement.

Authors:  Alexandra M Claus; Saara M Totterman; Christi J Sychterz; José G Tamez-Peña; R John Looney; Charles A Engh
Journal:  Clin Orthop Relat Res       Date:  2004-05       Impact factor: 4.176

10.  Interobserver and intraobserver variability in radiographic assessment of osteolysis.

Authors:  C Anderson Engh; Christi J Sychterz; Anthony M Young; David C Pollock; Sean D Toomey; Charles A Engh
Journal:  J Arthroplasty       Date:  2002-09       Impact factor: 4.757

View more
  7 in total

1.  Low incidence of groin pain and early failure with large metal articulation total hip arthroplasty.

Authors:  John B Meding; Lindsey K Meding; E Michael Keating; Michael E Berend
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

2.  Radiostereometric analysis study of tantalum compared with titanium acetabular cups and highly cross-linked compared with conventional liners in young patients undergoing total hip replacement.

Authors:  David C Ayers; Meridith Greene; Benjamin Snyder; Michelle Aubin; Jacob Drew; Charles Bragdon
Journal:  J Bone Joint Surg Am       Date:  2015-04-15       Impact factor: 5.284

Review 3.  Properties of open-cell porous metals and alloys for orthopaedic applications.

Authors:  Gladius Lewis
Journal:  J Mater Sci Mater Med       Date:  2013-07-13       Impact factor: 3.896

Review 4.  Additive manufacturing technique-designed metallic porous implants for clinical application in orthopedics.

Authors:  Chaohua Gao; Chenyu Wang; Hui Jin; Zhonghan Wang; Zuhao Li; Chenyu Shi; Yi Leng; Fan Yang; He Liu; Jincheng Wang
Journal:  RSC Adv       Date:  2018-07-16       Impact factor: 4.036

5.  Multicup reconstruction technique for the management of severe protrusio acetabular defects.

Authors:  Baochao Ji; Guoqing Li; Xiaogang Zhang; Yang Wang; Wenbo Mu; Li Cao
Journal:  Arthroplasty       Date:  2021-07-06

6.  LY450139 Inhibited Ti-Particle-Induced Bone Dissolution via Suppressing Notch and NF-κB Signaling Pathways.

Authors:  Jijian Gao; Peng Wu; Yingjun Chi; Hongyu Xu; Yong Zhao; Nanyan Song; Yuanqing Mao
Journal:  Calcif Tissue Int       Date:  2022-05-19       Impact factor: 4.000

7.  Survival of uncemented acetabular monoblock cups: evaluation of 210 hips in the Swedish Hip Arthroplasty Register.

Authors:  Rüdiger J Weiss; Nils P Hailer; André Stark; Johan Kärrholm
Journal:  Acta Orthop       Date:  2012-05-10       Impact factor: 3.717

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.