Literature DB >> 10379315

Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty.

D H Sochart1.   

Abstract

Polyethylene wear and the subsequent development of periprosthetic osteolysis are the major factors limiting the longevity of total hip arthroplasties. A minority eventually loosen, but no clinically applicable system exists for accurate early prediction of failure. The relationship between acetabular wear and the development of loosening, osteolysis, and revision was investigated in 235 Charnley low friction arthroplasties. The average age of the patient at surgery was 31.7 years (range, 17-39 years), and the duration of followup averaged 234 months (19.5 years; range, 74-364 months). Total wear averaged 2.1 mm (range, 0-7.2 mm), and the average wear rate was 0.11 mm per year (range, 0-0.55 mm/year), with the wear rate of revised components being twice that of surviving ones (0.19 mm/year versus 0.09 mm/year). The prevalence of osteolysis (33 hips, 14%) and of acetabular and femoral component loosening and revision rose significantly with increasing wear. Osteolysis also was associated significantly with femoral component loosening and revision, but the presence of calcar changes was not (90 hips, 38%). Twenty-five year survivorship exceeded 90% for arthroplasties with a wear rate less than 0.1 mm per year, but 20-year survivorship of acetabular components with a rate greater than 0.2 mm per year was below 30%, and none survived 25 years. For every additional millimeter of wear, the risk of acetabular revision in any one year increased by 45% and for the femur increased by 32%.

Entities:  

Mesh:

Year:  1999        PMID: 10379315

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  46 in total

1.  Implant wear and osteolysis with a hydroxylapatite-coated screw cup.

Authors:  E H van Haaren; I C Heyligers
Journal:  Int Orthop       Date:  2003-07-04       Impact factor: 3.075

2.  Wear analysis of chamfered elongated acetabular cup liners.

Authors:  Hsiao-Che Lin; Tzuo-Liang Luo; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2011-12-22       Impact factor: 2.602

3.  The prevalence of groin pain after metal-on-metal total hip arthroplasty and total hip resurfacing.

Authors:  Robert B Bartelt; Brandon J Yuan; Robert T Trousdale; Rafael J Sierra
Journal:  Clin Orthop Relat Res       Date:  2010-09       Impact factor: 4.176

4.  Highly crosslinked polyethylene reduces wear in total hip arthroplasty at 5 years.

Authors:  Jonathan Mutimer; Peter A Devane; Kathryn Adams; J Geoffrey Horne
Journal:  Clin Orthop Relat Res       Date:  2010-12       Impact factor: 4.176

5.  Changes of bone mineral density after cementless total hip arthroplasty with two different stems.

Authors:  Keiji Sano; Kouji Ito; Kengo Yamamoto
Journal:  Int Orthop       Date:  2007-01-16       Impact factor: 3.075

Review 6.  A systematic review of radiological outcomes of highly cross-linked polyethylene versus conventional polyethylene in total hip arthroplasty.

Authors:  Zongyou Mu; Jialiang Tian; Taixiang Wu; Jing Yang; Fuxing Pei
Journal:  Int Orthop       Date:  2009-01-29       Impact factor: 3.075

7.  Ideal femoral head size in total hip arthroplasty balances stability and volumetric wear.

Authors:  Michael B Cross; Denis Nam; David J Mayman
Journal:  HSS J       Date:  2012-09-13

8.  Suppression of wear-particle-induced pro-inflammatory cytokine and chemokine production in macrophages via NF-κB decoy oligodeoxynucleotide: a preliminary report.

Authors:  Tzu-Hua Lin; Zhenyu Yao; Taishi Sato; Michael Keeney; Chenguang Li; Jukka Pajarinen; Fan Yang; Kensuke Egashira; Stuart B Goodman
Journal:  Acta Biomater       Date:  2014-05-09       Impact factor: 8.947

Review 9.  Chronic inflammation in biomaterial-induced periprosthetic osteolysis: NF-κB as a therapeutic target.

Authors:  Tzu-hua Lin; Yasunobu Tamaki; Jukka Pajarinen; Heather A Waters; Deanna K Woo; Zhenyu Yao; Stuart B Goodman
Journal:  Acta Biomater       Date:  2013-10-01       Impact factor: 8.947

10.  Similar wear in total hip arthroplasties with metallic or zirconia femoral heads.

Authors:  Randy M Cohn; Alejandro González Della Valle; Margaret Peterson; Charles N Cornell
Journal:  HSS J       Date:  2008-07-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.