Literature DB >> 18506789

A 128-channel receive-only cardiac coil for highly accelerated cardiac MRI at 3 Tesla.

Melanie Schmitt1, Andreas Potthast, David E Sosnovik, Jonathan R Polimeni, Graham C Wiggins, Christina Triantafyllou, Lawrence L Wald.   

Abstract

A 128-channel receive-only array coil is described and tested for cardiac imaging at 3T. The coil is closely contoured to the body with a "clam-shell" geometry with 68 posterior and 60 anterior elements, each 75 mm in diameter, and arranged in a continuous overlapped array of hexagonal symmetry to minimize nearest neighbor coupling. Signal-to-noise ratio (SNR) and noise amplification for parallel imaging (G-factor) were evaluated in phantom and volunteer experiments. These results were compared to those of commercially available 24-channel and 32-channel coils in routine use for cardiac imaging. The in vivo measurements with the 128-channel coil resulted in SNR gains compared to the 24-channel coil (up to 2.2-fold in the apex). The 128- and 32-channel coils showed similar SNR in the heart, likely dominated by the similar element diameters of these coils. The maximum G-factor values were up to seven times better for a seven-fold acceleration factor (R=7) compared to the 24-channel coil and up to two-fold improved compared to the 32-channel coil. The ability of the 128-channel coil to facilitate highly accelerated cardiac imaging was demonstrated in four volunteers using acceleration factors up to seven-fold (R=7) in a single spatial dimension. Copyright (c) 2008 Wiley-Liss, Inc.

Mesh:

Year:  2008        PMID: 18506789      PMCID: PMC2548273          DOI: 10.1002/mrm.21598

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  12 in total

1.  MR evaluation of ventricular function: true fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: feasibility study.

Authors:  J Barkhausen; S G Ruehm; M Goyen; T Buck; G Laub; J F Debatin
Journal:  Radiology       Date:  2001-04       Impact factor: 11.105

2.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

3.  Analysis of wave behavior in lossy dielectric samples at high field.

Authors:  Qing X Yang; Jinghua Wang; Xiaoliang Zhang; Christopher M Collins; Michael B Smith; Haiying Liu; Xiao-Hong Zhu; J Thomas Vaughan; Kamil Ugurbil; Wei Chen
Journal:  Magn Reson Med       Date:  2002-05       Impact factor: 4.668

4.  Image brightening in samples of high dielectric constant.

Authors:  James Tropp
Journal:  J Magn Reson       Date:  2004-03       Impact factor: 2.229

5.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

6.  Cardiac CINE MR imaging with a 32-channel cardiac coil and parallel imaging: impact of acceleration factors on image quality and volumetric accuracy.

Authors:  Bernd J Wintersperger; Scott B Reeder; Konstantin Nikolaou; Olaf Dietrich; Armin Huber; Andreas Greiser; Titus Lanz; Maximilian F Reiser; Stefan O Schoenberg
Journal:  J Magn Reson Imaging       Date:  2006-02       Impact factor: 4.813

7.  64-channel array coil for single echo acquisition magnetic resonance imaging.

Authors:  Mary Preston McDougall; Steven M Wright
Journal:  Magn Reson Med       Date:  2005-08       Impact factor: 4.668

8.  32-channel 3 Tesla receive-only phased-array head coil with soccer-ball element geometry.

Authors:  G C Wiggins; C Triantafyllou; A Potthast; A Reykowski; M Nittka; L L Wald
Journal:  Magn Reson Med       Date:  2006-07       Impact factor: 4.668

9.  Proton spectroscopic imaging of the human brain using phased array detectors.

Authors:  L L Wald; S E Moyher; M R Day; S J Nelson; D B Vigneron
Journal:  Magn Reson Med       Date:  1995-09       Impact factor: 4.668

10.  Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays.

Authors:  D K Sodickson; W J Manning
Journal:  Magn Reson Med       Date:  1997-10       Impact factor: 4.668

View more
  56 in total

1.  An Improved Element Design for 64-Channel Planar Imaging.

Authors:  Chieh-Wei Chang; Katherine Lynn Moody; Mary Preston McDougall
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2011-08       Impact factor: 1.176

2.  Coil compression for accelerated imaging with Cartesian sampling.

Authors:  Tao Zhang; John M Pauly; Shreyas S Vasanawala; Michael Lustig
Journal:  Magn Reson Med       Date:  2012-04-09       Impact factor: 4.668

3.  Medusa: a scalable MR console using USB.

Authors:  Pascal P Stang; Steven M Conolly; Juan M Santos; John M Pauly; Greig C Scott
Journal:  IEEE Trans Med Imaging       Date:  2011-09-26       Impact factor: 10.048

4.  Finite element analysis applied to 3-T MR imaging of proximal femur microarchitecture: lower bone strength in patients with fragility fractures compared with control subjects.

Authors:  Gregory Chang; Stephen Honig; Ryan Brown; Cem M Deniz; Kenneth A Egol; James S Babb; Ravinder R Regatte; Chamith S Rajapakse
Journal:  Radiology       Date:  2014-04-02       Impact factor: 11.105

5.  Custom-fitted 16-channel bilateral breast coil for bidirectional parallel imaging.

Authors:  Anderson N Nnewihe; Thomas Grafendorfer; Bruce L Daniel; Paul Calderon; Marcus T Alley; Fraser Robb; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2011-02-01       Impact factor: 4.668

6.  Design of an MR image processing module on an FPGA chip.

Authors:  Limin Li; Alice M Wyrwicz
Journal:  J Magn Reson       Date:  2015-03-23       Impact factor: 2.229

7.  Size-adaptable "Trellis" structure for tailored MRI coil arrays.

Authors:  Bei Zhang; Ryan Brown; Martijn Cloos; Riccardo Lattanzi; Daniel Sodickson; Graham Wiggins
Journal:  Magn Reson Med       Date:  2018-12-21       Impact factor: 4.668

8.  Clinical performance of contrast enhanced abdominal pediatric MRI with fast combined parallel imaging compressed sensing reconstruction.

Authors:  Tao Zhang; Shilpy Chowdhury; Michael Lustig; Richard A Barth; Marcus T Alley; Thomas Grafendorfer; Paul D Calderon; Fraser J L Robb; John M Pauly; Shreyas S Vasanawala
Journal:  J Magn Reson Imaging       Date:  2013-10-11       Impact factor: 4.813

Review 9.  Massively parallel MRI detector arrays.

Authors:  Boris Keil; Lawrence L Wald
Journal:  J Magn Reson       Date:  2013-02-07       Impact factor: 2.229

Review 10.  Diffusion MR tractography of the heart.

Authors:  David E Sosnovik; Ruopeng Wang; Guangping Dai; Timothy G Reese; Van J Wedeen
Journal:  J Cardiovasc Magn Reson       Date:  2009-11-13       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.