Cardiac CINE MR imaging with a 32-channel cardiac coil and parallel imaging: impact of acceleration factors on image quality and volumetric accuracy.

Bernd J Wintersperger1, Scott B Reeder, Konstantin Nikolaou, Olaf Dietrich, Armin Huber, Andreas Greiser, Titus Lanz, Maximilian F Reiser, Stefan O Schoenberg.   

Abstract

PURPOSE: To assess the impact of parallel imaging algorithms on image quality and volumetric accuracy of CINE magnetic resonance imaging (MRI) with high temporal and spatial resolution using a new 32-channel dedicated cardiac phased array coil.
MATERIALS AND METHODS: Fourteen individuals underwent steady-state free precession (SSFP) CINE MRI using a 32-element phased-array coil and parallel imaging acceleration using spatiotemporal sensitivity encoding (TSENSE). Acquisition acceleration ranged from R = 2 to 7. In conjunction with data extracted from phantom measurements, contrast-to-noise ratio (CNR) performance was evaluated for each acceleration factor and subjective image quality was evaluated by two independent readers. In addition, volumetric assessment was performed for each acceleration factor based on a single breath-hold multi-slice data acquisition. Results were compared to nonTSENSE measurements.
RESULTS: CNR for non-accelerated CINE (R = 1) was 45.7 +/- 12.8 and showed a constant decrease with increase in acceleration of 51% at R = 4 and 86% at R = 7. CNR losses accompanied reductions in subjective image quality. Volumetric evaluation was accurate for R <or= 4, with significant underestimation of ejection fraction (EF) at higher accelerations.
CONCLUSION: This study shows that one-dimensional acceleration factors up to R = 4 allow accurate SSFP CINE MRI even though CNR is significantly reduced. This allows for a marked reduction in scan time and allows for multi-slice CINE imaging with high spatial and temporal resolution. (c) 2005 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16374875     DOI: 10.1002/jmri.20484

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  25 in total

1.  Single breath-hold magnetic resonance cine imaging for fast assessment of global and regional left ventricular function in clinical routine.

Authors:  Kai Nassenstein; Holger Eberle; Stefan Maderwald; Christoph J Jensen; Christina Heilmaier; Thomas Schlosser; Oliver Bruder
Journal:  Eur Radiol       Date:  2010-06-09       Impact factor: 5.315

Review 2.  Novel techniques for assessment of left ventricular systolic function.

Authors:  Sonal Chandra; Hicham Skali; Ron Blankstein
Journal:  Heart Fail Rev       Date:  2011-07       Impact factor: 4.214

3.  Evaluation of image quality of a 32-channel versus a 12-channel head coil at 1.5T for MR imaging of the brain.

Authors:  P T Parikh; G S Sandhu; K A Blackham; M D Coffey; D Hsu; K Liu; J Jesberger; M Griswold; J L Sunshine
Journal:  AJNR Am J Neuroradiol       Date:  2010-12-16       Impact factor: 3.825

4.  Dual-contrast single breath-hold 3D abdominal MR imaging.

Authors:  Richard Winkelmann; Peter Börnert; Jan De Becker; Romhild Hoogeveen; Peter Mazurkewitz; Olaf Dössel
Journal:  MAGMA       Date:  2006-11-24       Impact factor: 2.310

5.  Custom-fitted 16-channel bilateral breast coil for bidirectional parallel imaging.

Authors:  Anderson N Nnewihe; Thomas Grafendorfer; Bruce L Daniel; Paul Calderon; Marcus T Alley; Fraser Robb; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2011-02-01       Impact factor: 4.668

6.  Improved radial GRAPPA calibration for real-time free-breathing cardiac imaging.

Authors:  Nicole Seiberlich; Philipp Ehses; Jeff Duerk; Robert Gilkeson; Mark Griswold
Journal:  Magn Reson Med       Date:  2010-09-24       Impact factor: 4.668

Review 7.  Parallel magnetic resonance imaging.

Authors:  Ulrich Katscher; Peter Börnert
Journal:  Neurotherapeutics       Date:  2007-07       Impact factor: 7.620

8.  A 128-channel receive-only cardiac coil for highly accelerated cardiac MRI at 3 Tesla.

Authors:  Melanie Schmitt; Andreas Potthast; David E Sosnovik; Jonathan R Polimeni; Graham C Wiggins; Christina Triantafyllou; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2008-06       Impact factor: 4.668

Review 9.  Highly accelerated cardiovascular MR imaging using many channel technology: concepts and clinical applications.

Authors:  Thoralf Niendorf; Daniel K Sodickson
Journal:  Eur Radiol       Date:  2007-06-12       Impact factor: 5.315

10.  Comparison of two single-breath-held 3-D acquisitions with multi-breath-held 2-D cine steady-state free precession MRI acquisition in children with single ventricles.

Authors:  Lamya A Atweh; Nicholas A Dodd; Ramkumar Krishnamurthy; Amol Pednekar; Zili D Chu; Rajesh Krishnamurthy
Journal:  Pediatr Radiol       Date:  2016-02-22