Literature DB >> 22267961

An Improved Element Design for 64-Channel Planar Imaging.

Chieh-Wei Chang1, Katherine Lynn Moody, Mary Preston McDougall.   

Abstract

Investigation of highly accelerated MRI has developed into a lively corner in the hardware and methodology arena in recent years. At the extreme of (one-dimensional) acceleration, our group introduced Single Echo Acquisition (SEA) imaging, in which the need to phase encode a 64×N(readout) image is eliminated and replaced with the well-localized spatial information obtained from an array of 64 very narrow, long, parallel coils. The narrow coil width (2mm) that facilitates this is accompanied by a concomitant constraint on the useful imaging depth. This note describes a 64-element planar array, constructed within the same 8×13cm total footprint as the original SEA array, still enabling full acceleration in one dimension, but with an element design modified to increase the imaging depth. This was accomplished by lowering the outer conducting legs of the planar pair with respect to the center conductor and adding a geometric decoupling configuration away from the imaging field of view. The element has been called a dual-plane pair in that the current carrying rungs in the imaging FOV function exactly as the planar pair, but are simply placed in two separate planes (sides of PCB in this case).

Entities:  

Year:  2011        PMID: 22267961      PMCID: PMC3259609          DOI: 10.1002/cmr.b.20203

Source DB:  PubMed          Journal:  Concepts Magn Reson Part B Magn Reson Eng        ISSN: 1552-5031            Impact factor:   1.176


  11 in total

1.  Partially parallel imaging with localized sensitivities (PILS).

Authors:  M A Griswold; P M Jakob; M Nittka; J W Goldfarb; A Haase
Journal:  Magn Reson Med       Date:  2000-10       Impact factor: 4.668

2.  A decoupled coil detector array for fast image acquisition in magnetic resonance imaging.

Authors:  D Kwiat; S Einav; G Navon
Journal:  Med Phys       Date:  1991 Mar-Apr       Impact factor: 4.071

3.  64-channel array coil for single echo acquisition magnetic resonance imaging.

Authors:  Mary Preston McDougall; Steven M Wright
Journal:  Magn Reson Med       Date:  2005-08       Impact factor: 4.668

4.  32-element receiver-coil array for cardiac imaging.

Authors:  Christopher J Hardy; Harvey E Cline; Randy O Giaquinto; Thoralf Niendorf; Aaron K Grant; Daniel K Sodickson
Journal:  Magn Reson Med       Date:  2006-05       Impact factor: 4.668

5.  Single echo acquisition MRI using RF encoding.

Authors:  Steven M Wright; Mary Preston McDougall
Journal:  NMR Biomed       Date:  2009-11       Impact factor: 4.044

6.  128-channel body MRI with a flexible high-density receiver-coil array.

Authors:  Christopher J Hardy; Randy O Giaquinto; Joseph E Piel; Kenneth W Rohling; Luca Marinelli; Daniel J Blezek; Eric W Fiveland; Robert D Darrow; Thomas K F Foo
Journal:  J Magn Reson Imaging       Date:  2008-11       Impact factor: 4.813

7.  A 128-channel receive-only cardiac coil for highly accelerated cardiac MRI at 3 Tesla.

Authors:  Melanie Schmitt; Andreas Potthast; David E Sosnovik; Jonathan R Polimeni; Graham C Wiggins; Christina Triantafyllou; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2008-06       Impact factor: 4.668

8.  A flow quantification method using fluid dynamics regularization and MR tagging.

Authors:  Yuttapong Jiraraksopakun; Mary P McDougall; Steven M Wright; Jim X Ji
Journal:  IEEE Trans Biomed Eng       Date:  2010-02-17       Impact factor: 4.538

9.  Fast MRI data acquisition using multiple detectors.

Authors:  M Hutchinson; U Raff
Journal:  Magn Reson Med       Date:  1988-01       Impact factor: 4.668

10.  Progress in visualizing turbulent flow using single-echo acquisition imaging.

Authors:  Steven M Wright; Mary Preston McDougall; John C Bosshard
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2006
View more
  2 in total

1.  A parallel imaging approach to wide-field MR microscopy.

Authors:  Mary Preston McDougall; Steven M Wright
Journal:  Magn Reson Med       Date:  2011-12-02       Impact factor: 4.668

Review 2.  Massively parallel MRI detector arrays.

Authors:  Boris Keil; Lawrence L Wald
Journal:  J Magn Reson       Date:  2013-02-07       Impact factor: 2.229

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.