Literature DB >> 18491510

Combined kV and MV imaging for real-time tracking of implanted fiducial markers.

R D Wiersma1, Weihua Mao, L Xing.   

Abstract

In the presence of intrafraction organ motion, target localization uncertainty can greatly hamper the advantage of highly conformal dose techniques such as intensity modulated radiation therapy (IMRT). To minimize the adverse dosimetric effect caused by tumor motion, a real-time knowledge of the tumor position is required throughout the beam delivery process. The recent integration of onboard kV diagnostic imaging together with MV electronic portal imaging devices on linear accelerators can allow for real-time three-dimensional (3D) tumor position monitoring during a treatment delivery. The aim of this study is to demonstrate a near real-time 3D internal fiducial tracking system based on the combined use of kV and MV imaging. A commercially available radiotherapy system equipped with both kV and MV imaging systems was used in this work. A hardware video frame grabber was used to capture both kV and MV video streams simultaneously through independent video channels at 30 frames per second. The fiducial locations were extracted from the kV and MV images using a software tool. The geometric tracking capabilities of the system were evaluated using a pelvic phantom with embedded fiducials placed on a moveable stage. The maximum tracking speed of the kV/MV system is approximately 9 Hz, which is primarily limited by the frame rate of the MV imager. The geometric accuracy of the system is found to be on the order of less than 1 mm in all three spatial dimensions. The technique requires minimal hardware modification and is potentially useful for image-guided radiation therapy systems.

Entities:  

Mesh:

Year:  2008        PMID: 18491510      PMCID: PMC2811551          DOI: 10.1118/1.2842072

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  26 in total

1.  Breathing-synchronized radiotherapy program at the University of California Davis Cancer Center.

Authors:  H D Kubo; P M Len; S Minohara; H Mostafavi
Journal:  Med Phys       Date:  2000-02       Impact factor: 4.071

2.  Robotic motion compensation for respiratory movement during radiosurgery.

Authors:  A Schweikard; G Glosser; M Bodduluri; M J Murphy; J R Adler
Journal:  Comput Aided Surg       Date:  2000

3.  Multi-institutional clinical experience with the Calypso System in localization and continuous, real-time monitoring of the prostate gland during external radiotherapy.

Authors:  Patrick Kupelian; Twyla Willoughby; Arul Mahadevan; Toufik Djemil; Geoffrey Weinstein; Shirish Jani; Charles Enke; Timothy Solberg; Nicholas Flores; David Liu; David Beyer; Lisa Levine
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-12-21       Impact factor: 7.038

Review 4.  Overview of image-guided radiation therapy.

Authors:  Lei Xing; Brian Thorndyke; Eduard Schreibmann; Yong Yang; Tian-Fang Li; Gwe-Ya Kim; Gary Luxton; Albert Koong
Journal:  Med Dosim       Date:  2006       Impact factor: 1.482

5.  Examination of geometric and dosimetric accuracies of gated step-and-shoot intensity modulated radiation therapy.

Authors:  R D Wiersma; L Xing
Journal:  Med Phys       Date:  2007-10       Impact factor: 4.071

6.  Technical and dosimetric aspects of respiratory gating using a pressure-sensor motion monitoring system.

Authors:  X Allen Li; Christopher Stepaniak; Elizabeth Gore
Journal:  Med Phys       Date:  2006-01       Impact factor: 4.071

7.  Fluoroscopic tracking of multiple implanted fiducial markers using multiple object tracking.

Authors:  Xiaoli Tang; Greg C Sharp; Steve B Jiang
Journal:  Phys Med Biol       Date:  2007-06-11       Impact factor: 3.609

8.  On the use of EPID-based implanted marker tracking for 4D radiotherapy.

Authors:  P J Keall; A D Todor; S S Vedam; C L Bartee; J V Siebers; V R Kini; R Mohan
Journal:  Med Phys       Date:  2004-12       Impact factor: 4.071

9.  Lung volume assessment for a cross-comparison of two breathing-adapted techniques in radiotherapy.

Authors:  Luc Simon; Philippe Giraud; Vincent Servois; Jean-Claude Rosenwald
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-10-01       Impact factor: 7.038

10.  Individualized gating windows based on four-dimensional CT information for respiration-gated radiotherapy.

Authors:  Nicole M Wink; Ming Chao; Jiji Antony; Lei Xing
Journal:  Phys Med Biol       Date:  2007-12-19       Impact factor: 3.609

View more
  44 in total

1.  Feasibility of low-dose single-view 3D fiducial tracking concurrent with external beam delivery.

Authors:  Michael A Speidel; Brian P Wilfley; Annie Hsu; Dimitre Hristov
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

2.  Evaluating the image quality of cone beam CT acquired during rotational delivery.

Authors:  S A Yoganathan; K J Maria Das; K Maria Midunvaleja; D Gowtham Raj; Arpita Agarwal; J Velmurugan; Shaleen Kumar
Journal:  Br J Radiol       Date:  2015-07-30       Impact factor: 3.039

3.  Optimized hybrid megavoltage-kilovoltage imaging protocol for volumetric prostate arc therapy.

Authors:  Wu Liu; Rodney D Wiersma; Lei Xing
Journal:  Int J Radiat Oncol Biol Phys       Date:  2010-05-14       Impact factor: 7.038

4.  Fast internal marker tracking algorithm for onboard MV and kV imaging systems.

Authors:  W Mao; R D Wiersma; L Xing
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

5.  Four-dimensional inverse treatment planning with inclusion of implanted fiducials in IMRT segmented fields.

Authors:  Yunzhi Ma; Louis Lee; O Keshet; Paul Keall; Lei Xing
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

6.  A Bayesian approach to real-time 3D tumor localization via monoscopic x-ray imaging during treatment delivery.

Authors:  Ruijiang Li; Benjamin P Fahimian; Lei Xing
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

7.  Metal artifact correction for x-ray computed tomography using kV and selective MV imaging.

Authors:  Meng Wu; Andreas Keil; Dragos Constantin; Josh Star-Lack; Lei Zhu; Rebecca Fahrig
Journal:  Med Phys       Date:  2014-12       Impact factor: 4.071

8.  Monitoring external beam radiotherapy using real-time beam visualization.

Authors:  Cesare H Jenkins; Dominik J Naczynski; Shu-Jung S Yu; Lei Xing
Journal:  Med Phys       Date:  2015-01       Impact factor: 4.071

9.  Optimizing fiducial visibility on periodically acquired megavoltage and kilovoltage image pairs during prostate volumetric modulated arc therapy.

Authors:  Pengpeng Zhang; Laura Happersett; Bosky Ravindranath; Michael Zelefsky; Gig Mageras; Margie Hunt
Journal:  Med Phys       Date:  2016-05       Impact factor: 4.071

10.  Optimizing monoscopic kV fluoro acquisition for prostate intrafraction motion evaluation.

Authors:  Justus Adamson; Qiuwen Wu
Journal:  Phys Med Biol       Date:  2008-12-10       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.