Literature DB >> 17534903

Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint.

Kai Tobias Block1, Martin Uecker, Jens Frahm.   

Abstract

The reconstruction of artifact-free images from radially encoded MRI acquisitions poses a difficult task for undersampled data sets, that is for a much lower number of spokes in k-space than data samples per spoke. Here, we developed an iterative reconstruction method for undersampled radial MRI which (i) is based on a nonlinear optimization, (ii) allows for the incorporation of prior knowledge with use of penalty functions, and (iii) deals with data from multiple coils. The procedure arises as a two-step mechanism which first estimates the coil profiles and then renders a final image that complies with the actual observations. Prior knowledge is introduced by penalizing edges in coil profiles and by a total variation constraint for the final image. The latter condition leads to an effective suppression of undersampling (streaking) artifacts and further adds a certain degree of denoising. Apart from simulations, experimental results for a radial spin-echo MRI sequence are presented for phantoms and human brain in vivo at 2.9 T using 24, 48, and 96 spokes with 256 data samples. In comparison to conventional reconstructions (regridding) the proposed method yielded visually improved image quality in all cases.

Entities:  

Mesh:

Year:  2007        PMID: 17534903     DOI: 10.1002/mrm.21236

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  187 in total

Review 1.  Real-time magnetic resonance imaging of cardiac function and flow-recent progress.

Authors:  Shuo Zhang; Arun A Joseph; Dirk Voit; Sebastian Schaetz; Klaus-Dietmar Merboldt; Christina Unterberg-Buchwald; Anja Hennemuth; Joachim Lotz; Jens Frahm
Journal:  Quant Imaging Med Surg       Date:  2014-10

Review 2.  Imaging sequences in cardiovascular magnetic resonance: current role, evolving applications, and technical challenges.

Authors:  El-Sayed H Ibrahim
Journal:  Int J Cardiovasc Imaging       Date:  2012-03-25       Impact factor: 2.357

3.  MODEL-BASED IMAGE RECONSTRUCTION FOR MRI.

Authors:  Jeffrey A Fessler
Journal:  IEEE Signal Process Mag       Date:  2010-07-01       Impact factor: 12.551

4.  Self-gated MRI of multiple beat morphologies in the presence of arrhythmias.

Authors:  Francisco Contijoch; Srikant Kamesh Iyer; James J Pilla; Paul Yushkevich; Joseph H Gorman; Robert C Gorman; Harold Litt; Yuchi Han; Walter R T Witschey
Journal:  Magn Reson Med       Date:  2016-08-31       Impact factor: 4.668

5.  Improving non-contrast-enhanced steady-state free precession angiography with compressed sensing.

Authors:  Tolga Cukur; Michael Lustig; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2009-05       Impact factor: 4.668

6.  Correlated spectroscopic imaging of calf muscle in three spatial dimensions using group sparse reconstruction of undersampled single and multichannel data.

Authors:  Neil E Wilson; Brian L Burns; Zohaib Iqbal; M Albert Thomas
Journal:  Magn Reson Med       Date:  2015-09-18       Impact factor: 4.668

Review 7.  Fast, free-breathing and motion-minimized techniques for pediatric body magnetic resonance imaging.

Authors:  Camilo Jaimes; John E Kirsch; Michael S Gee
Journal:  Pediatr Radiol       Date:  2018-08-04

8.  Scan-specific robust artificial-neural-networks for k-space interpolation (RAKI) reconstruction: Database-free deep learning for fast imaging.

Authors:  Mehmet Akçakaya; Steen Moeller; Sebastian Weingärtner; Kâmil Uğurbil
Journal:  Magn Reson Med       Date:  2018-09-18       Impact factor: 4.668

9.  Respiratory motion-compensated radial dynamic contrast-enhanced (DCE)-MRI of chest and abdominal lesions.

Authors:  Wei Lin; Junyu Guo; Mark A Rosen; Hee Kwon Song
Journal:  Magn Reson Med       Date:  2008-11       Impact factor: 4.668

10.  Low-rank plus sparse compressed sensing for accelerated proton resonance frequency shift MR temperature imaging.

Authors:  Zhipeng Cao; John C Gore; William A Grissom
Journal:  Magn Reson Med       Date:  2019-01-31       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.