Sparse MRI: The application of compressed sensing for rapid MR imaging.

Michael Lustig1, David Donoho, John M Pauly.   

Abstract

The sparsity which is implicit in MR images is exploited to significantly undersample k-space. Some MR images such as angiograms are already sparse in the pixel representation; other, more complicated images have a sparse representation in some transform domain-for example, in terms of spatial finite-differences or their wavelet coefficients. According to the recently developed mathematical theory of compressed-sensing, images with a sparse representation can be recovered from randomly undersampled k-space data, provided an appropriate nonlinear recovery scheme is used. Intuitively, artifacts due to random undersampling add as noise-like interference. In the sparse transform domain the significant coefficients stand out above the interference. A nonlinear thresholding scheme can recover the sparse coefficients, effectively recovering the image itself. In this article, practical incoherent undersampling schemes are developed and analyzed by means of their aliasing interference. Incoherence is introduced by pseudo-random variable-density undersampling of phase-encodes. The reconstruction is performed by minimizing the l(1) norm of a transformed image, subject to data fidelity constraints. Examples demonstrate improved spatial resolution and accelerated acquisition for multislice fast spin-echo brain imaging and 3D contrast enhanced angiography. (c) 2007 Wiley-Liss, Inc.

Mesh:

Year:  2007        PMID: 17969013     DOI: 10.1002/mrm.21391

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  1065 in total

1.  Quantitative two-dimensional ultrashort echo time magnetization transfer (2D UTE-MT) imaging of cortical bone.

Authors:  Ya-Jun Ma; Anthony Tadros; Jiang Du; Eric Y Chang
Journal:  Magn Reson Med       Date:  2017-08-03       Impact factor: 4.668

2.  Fast cardiac T1 mapping in mice using a model-based compressed sensing method.

Authors:  Wen Li; Mark Griswold; Xin Yu
Journal:  Magn Reson Med       Date:  2011-12-09       Impact factor: 4.668

3.  Reconstruction of dynamic image series from undersampled MRI data using data-driven model consistency condition (MOCCO).

Authors:  Julia V Velikina; Alexey A Samsonov
Journal:  Magn Reson Med       Date:  2014-11-14       Impact factor: 4.668

4.  Metal artifact reduction MRI of total ankle arthroplasty implants.

Authors:  Cesar de Cesar Netto; Lucas F Fonseca; Benjamin Fritz; Steven E Stern; Esther Raithel; Mathias Nittka; Lew C Schon; Jan Fritz
Journal:  Eur Radiol       Date:  2017-12-07       Impact factor: 5.315

5.  Rotator cuff tendon assessment using magic-angle insensitive 3D ultrashort echo time cones magnetization transfer (UTE-Cones-MT) imaging and modeling with histological correlation.

Authors:  Yanchun Zhu; Xin Cheng; Yajun Ma; Jonathan H Wong; Yaoqin Xie; Jiang Du; Eric Y Chang
Journal:  J Magn Reson Imaging       Date:  2017-12-08       Impact factor: 4.813

6.  PCLR: phase-constrained low-rank model for compressive diffusion-weighted MRI.

Authors:  Hao Gao; Longchuan Li; Kai Zhang; Weifeng Zhou; Xiaoping Hu
Journal:  Magn Reson Med       Date:  2013-12-10       Impact factor: 4.668

7.  Improving non-contrast-enhanced steady-state free precession angiography with compressed sensing.

Authors:  Tolga Cukur; Michael Lustig; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2009-05       Impact factor: 4.668

8.  Ramped hybrid encoding for improved ultrashort echo time imaging.

Authors:  Hyungseok Jang; Curtis N Wiens; Alan B McMillan
Journal:  Magn Reson Med       Date:  2015-09-18       Impact factor: 4.668

9.  3D Cine Magnetic Resonance Imaging of Rat Lung ARDS using Gradient-modulated SWIFT with Retrospective Respiratory Gating.

Authors:  Naoharu Kobayashi; Jianxun Lei; Lynn Utecht; Michael Garwood; David Ingbar; Maneesh Bhargava
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-02-21

10.  Correlated spectroscopic imaging of calf muscle in three spatial dimensions using group sparse reconstruction of undersampled single and multichannel data.

Authors:  Neil E Wilson; Brian L Burns; Zohaib Iqbal; M Albert Thomas
Journal:  Magn Reson Med       Date:  2015-09-18       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.