Literature DB >> 18230481

SPRINT II: a second generation single photon ring tomograph.

W L Rogers1, N H Clinthorne, L Shao, P Chiao, Y Ding, J A Stamos, K F Koral.   

Abstract

SPRINT II is a stationary detector ring tomograph designed for brain imaging. Eleven two-dimensional sodium iodide camera modules that use maximum-likelihood position logic are arranged in a 50-cm-diameter ring with a scintillator packing fraction of 96%. A 34-cm-diameter rotating lead aperture ring containing either 10 or 12 slits is used for in-plane collimation, while the z-axis collimator is constructed of parallel lead foil rings. The field of view is 22 cm in diameter by 12 cm long. Sensitivity is 10 count/s/muCi for an on-axis (99m)Tc point source and 8500 count/s/muCi/cm(3) for 19.8-cm-diameter by 6.2-cm-long cylindrical source. Longitudinal resolution is 10 mm FWHM, and in-plane resolution varies from 8 mm FWHM on-axis to 5 mm FWHM at a radius of 9 cm. Performance results are presented.

Entities:  

Year:  1988        PMID: 18230481     DOI: 10.1109/42.14511

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  10 in total

Review 1.  Dynamic single photon emission computed tomography--basic principles and cardiac applications.

Authors:  Grant T Gullberg; Bryan W Reutter; Arkadiusz Sitek; Jonathan S Maltz; Thomas F Budinger
Journal:  Phys Med Biol       Date:  2010-09-22       Impact factor: 3.609

2.  C-SPECT - a Clinical Cardiac SPECT/Tct Platform: Design Concepts and Performance Potential.

Authors:  Wei Chang; Caesar E Ordonez; Haoning Liang; Yusheng Li; Jingai Liu
Journal:  IEEE Trans Nucl Sci       Date:  2009-10-06       Impact factor: 1.679

Review 3.  The origins of SPECT and SPECT/CT.

Authors:  Brian F Hutton
Journal:  Eur J Nucl Med Mol Imaging       Date:  2013-11-12       Impact factor: 9.236

4.  Analytic Derivation and Monte Carlo Validation of a Sensitivity Formula for Slit-Slit Collimation With Penetration.

Authors:  Ahmet S Ayan; Scott D Metzler; Roberto Accorsi
Journal:  IEEE Trans Nucl Sci       Date:  2010-02-08       Impact factor: 1.679

Review 5.  Brain single-photon emission CT physics principles.

Authors:  R Accorsi
Journal:  AJNR Am J Neuroradiol       Date:  2008-06-26       Impact factor: 3.825

6.  Multidivergent-beam stationary cardiac SPECT.

Authors:  Gengsheng L Zeng; Andrew M Stevens
Journal:  Med Phys       Date:  2009-07       Impact factor: 4.071

7.  Slit-Slat and Multislit-Slat Collimator Design and Experimentally Acquired Phantom Images from a Rotating Prototype.

Authors:  Scott D Metzler; Roberto Accorsi; Ahmet S Ayan; Ronald J Jaszczak
Journal:  IEEE Trans Nucl Sci       Date:  2010-02-01       Impact factor: 1.679

8.  The geometric response function for convergent slit-slat collimators.

Authors:  Yusheng Li; James Oldendick; Caesar E Ordonez; Wei Chang
Journal:  Phys Med Biol       Date:  2009-02-13       Impact factor: 3.609

9.  Is absolute quantification of dopaminergic neurotransmission studies with 123I SPECT ready for clinical use?

Authors:  Habib Zaidi; Georges El Fakhri
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-07       Impact factor: 9.236

10.  Finding Optimized Conditions of Slit-Slat and Multislit-Slat Collimation for Breast Imaging.

Authors:  Daekwang Kau; Scott D Metzler
Journal:  IEEE Trans Nucl Sci       Date:  2012-02-01       Impact factor: 1.679

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.