Literature DB >> 24347677

Finding Optimized Conditions of Slit-Slat and Multislit-Slat Collimation for Breast Imaging.

Daekwang Kau1, Scott D Metzler1.   

Abstract

In order to develop a breast-imaging system for Single Photon Emission Computed Tomography (SPECT) using slit-slat and multislit-slat collimators, we searched for optimized geometric parameters of the collimators. For this study, we employed two independent metrics to validate each result: 1) Signal to Noise Ratio (SNR) based on the Cramer-Rao lower Bound (CRB) and 2) contrast at the same noise level from an ensemble. We calculated SNR values using forward-projection data of an anthropomorphic digital phantom containing two lesions in the breast (one at the chest wall and the other at the center) with a simulated slit-slat collimator as a function of the collimator's geometric parameters. We also calculated contrast values from reconstructed images with noise. Based on the results from the slit-slat case, we investigated angular range, SNR, and contrast for the multislit-slat. We saw similar trends of the two metrics. One interesting property of the multislit-slat is that the imaging performance depends on the orientation of the field of view (FOV) of the side slits. When we compared the metric values for the slit-slat and multislit-slat, improvement was seen only when the lesion was in the FOV of the side slits. Therefore, tuning the parameters of the multislit-slat to optimally detect lesions at the chest wall might be a sensible option since the slit-slat already provides good image quality for center and superficial lesions.

Entities:  

Keywords:  sensitivity; single photon emission computed tomography (SPECT); slit-slat

Year:  2012        PMID: 24347677      PMCID: PMC3863385          DOI: 10.1109/TNS.2011.2177912

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  14 in total

1.  Analytic derivation of pinhole collimation sensitivity for a general source model using spherical harmonics.

Authors:  Yu-Sheng Li; James E Oldendick; Wei Chang
Journal:  Phys Med Biol       Date:  2010-04-19       Impact factor: 3.609

2.  C-SPECT - a Clinical Cardiac SPECT/Tct Platform: Design Concepts and Performance Potential.

Authors:  Wei Chang; Caesar E Ordonez; Haoning Liang; Yusheng Li; Jingai Liu
Journal:  IEEE Trans Nucl Sci       Date:  2009-10-06       Impact factor: 1.679

3.  Collimator optimization for detection and quantitation tasks: application to gallium-67 imaging.

Authors:  Stephen C Moore; Marie Foley Kijewski; Georges El Fakhri
Journal:  IEEE Trans Med Imaging       Date:  2005-10       Impact factor: 10.048

4.  Verification of the sensitivity and resolution dependence on the incidence angle for slit-slat collimation.

Authors:  J R Novak; A S Ayan; R Accorsi; S D Metzler
Journal:  Phys Med Biol       Date:  2008-01-23       Impact factor: 3.609

5.  SPRINT: A Stationary Detector Single Photon Ring Tomograph for Brain Imaging.

Authors:  W L Rogers; N H Clinthorne; J Stamos; K F Koral; R Mayans; J W Keyes; J J Williams; W P Snapp; G F Knoll
Journal:  IEEE Trans Med Imaging       Date:  1982       Impact factor: 10.048

6.  SPRINT II: a second generation single photon ring tomograph.

Authors:  W L Rogers; N H Clinthorne; L Shao; P Chiao; Y Ding; J A Stamos; K F Koral
Journal:  IEEE Trans Med Imaging       Date:  1988       Impact factor: 10.048

7.  Design of a novel slit-slat collimator system for SPECT imaging of the human brain.

Authors:  S T Mahmood; K Erlandsson; I Cullum; B F Hutton
Journal:  Phys Med Biol       Date:  2009-05-13       Impact factor: 3.609

8.  Slit-Slat and Multislit-Slat Collimator Design and Experimentally Acquired Phantom Images from a Rotating Prototype.

Authors:  Scott D Metzler; Roberto Accorsi; Ahmet S Ayan; Ronald J Jaszczak
Journal:  IEEE Trans Nucl Sci       Date:  2010-02-01       Impact factor: 1.679

9.  The geometric response function for convergent slit-slat collimators.

Authors:  Yusheng Li; James Oldendick; Caesar E Ordonez; Wei Chang
Journal:  Phys Med Biol       Date:  2009-02-13       Impact factor: 3.609

10.  Performance evaluation of SPRINT, a single photon ring tomography for brain imaging.

Authors:  W L Rogers; N H Clinthorne; J Stamos; K F Koral; R Mayans; G F Knoll; J Juni; J W Keyes; B A Harkness
Journal:  J Nucl Med       Date:  1984-09       Impact factor: 10.057

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.