Literature DB >> 20352062

Analytic Derivation and Monte Carlo Validation of a Sensitivity Formula for Slit-Slit Collimation With Penetration.

Ahmet S Ayan1, Scott D Metzler, Roberto Accorsi.   

Abstract

A slit-slit collimator consists of two orthogonal slits and can be conceptualized as a generalized pinhole. Since the two slits are independent of each other, there can be independent axial and transaxial acceptance angles. A small axial acceptance angle may help mitigate axial blurring with circular orbits, allowing multiple copies axially. In addition, since the two slit planes can be placed at different distances with respect to the source, a better detector usage can be achieved, especially in the case of detectors and imaged objects with different aspect ratios. In this paper an analytical expression is derived for the sensitivity of slit-slit collimation including effective slit widths for photon penetration. An analytical expression for sensitivity is necessary in order to accurately model the system response. This expression could also be useful for comparing the slit-slit's sensitivity performance with others. When the effective slit width is used instead of the geometric slit width, the derived analytical expression accurately accounts for photon penetration of the aperture. The derived expression for the sensitivity was validated by Monte Carlo simulation for both geometric and penetrative cases.

Entities:  

Year:  2010        PMID: 20352062      PMCID: PMC2844737          DOI: 10.1109/TNS.2009.2030580

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  11 in total

1.  The performance of a gamma camera for the visualization of radioactive isotope in vivo.

Authors:  J R MALLARD; M J MYERS
Journal:  Phys Med Biol       Date:  1963-06       Impact factor: 3.609

2.  An analytical algorithm for skew-slit collimator SPECT with uniform attenuation correction.

Authors:  Qiulin Tang; Gengsheng L Zeng; Qiu Huang
Journal:  Phys Med Biol       Date:  2006-11-09       Impact factor: 3.609

3.  An analytical algorithm for skew-slit imaging geometry with nonuniform attenuation correction.

Authors:  Qiu Huang; Gengsheng L Zeng
Journal:  Med Phys       Date:  2006-04       Impact factor: 4.071

4.  On-axis sensitivity and resolution of a slit-slat collimator.

Authors:  Scott D Metzler; Roberto Accorsi; John R Novak; Ahmet S Ayan; Ronald J Jaszczak
Journal:  J Nucl Med       Date:  2006-11       Impact factor: 10.057

5.  Image reconstruction from cone-beam projections: necessary and sufficient conditions and reconstruction methods.

Authors:  B D Smith
Journal:  IEEE Trans Med Imaging       Date:  1985       Impact factor: 10.048

6.  SPRINT: A Stationary Detector Single Photon Ring Tomograph for Brain Imaging.

Authors:  W L Rogers; N H Clinthorne; J Stamos; K F Koral; R Mayans; J W Keyes; J J Williams; W P Snapp; G F Knoll
Journal:  IEEE Trans Med Imaging       Date:  1982       Impact factor: 10.048

7.  SPRINT II: a second generation single photon ring tomograph.

Authors:  W L Rogers; N H Clinthorne; L Shao; P Chiao; Y Ding; J A Stamos; K F Koral
Journal:  IEEE Trans Med Imaging       Date:  1988       Impact factor: 10.048

8.  Derivation and validation of a sensitivity formula for slit-slat collimation.

Authors:  R Accorsi; J R Novak; A S Ayan; S D Metzler
Journal:  IEEE Trans Med Imaging       Date:  2008-05       Impact factor: 10.048

9.  Evaluation of novel whole-body high-resolution rodent SPECT (Linoview) based on direct acquisition of linogram projections.

Authors:  Stephan Walrand; François Jamar; Marion de Jong; Stanislas Pauwels
Journal:  J Nucl Med       Date:  2005-11       Impact factor: 10.057

10.  Performance evaluation of SPRINT, a single photon ring tomography for brain imaging.

Authors:  W L Rogers; N H Clinthorne; J Stamos; K F Koral; R Mayans; G F Knoll; J Juni; J W Keyes; B A Harkness
Journal:  J Nucl Med       Date:  1984-09       Impact factor: 10.057

View more
  2 in total

1.  High-Resolution Anamorphic SPECT Imaging.

Authors:  Heather L Durko; Harrison H Barrett; Lars R Furenlid
Journal:  IEEE Trans Nucl Sci       Date:  2014-06       Impact factor: 1.679

2.  Adaptive SPECT imaging with crossed-slit apertures.

Authors:  Heather L Durko; Lars R Furenlid
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-08-17
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.