Literature DB >> 19218734

The geometric response function for convergent slit-slat collimators.

Yusheng Li1, James Oldendick, Caesar E Ordonez, Wei Chang.   

Abstract

We have derived an analytic geometric transfer function (GTF) for a convergent slit-slat collimator that treats the parallel slit-slat collimator as a special case. The effective point spread function (EPSF) is then derived from the GTF through the Fourier transform. The results of these derivations give an accurate description of the complete geometric response for a slit-slat collimator that includes the effects of the shape and orientation of the slit and slats. We have also derived exact and approximate sensitivity formulae and spatial resolution formulae using the EPSF.

Entities:  

Mesh:

Year:  2009        PMID: 19218734      PMCID: PMC3699207          DOI: 10.1088/0031-9155/54/6/006

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  12 in total

Review 1.  Review of convergent beam tomography in single photon emission computed tomography.

Authors:  G T Gullberg; G L Zeng; F L Datz; P E Christian; C H Tung; H T Morgan
Journal:  Phys Med Biol       Date:  1992-03       Impact factor: 3.609

2.  On-axis sensitivity and resolution of a slit-slat collimator.

Authors:  Scott D Metzler; Roberto Accorsi; John R Novak; Ahmet S Ayan; Ronald J Jaszczak
Journal:  J Nucl Med       Date:  2006-11       Impact factor: 10.057

3.  Fourier correction for spatially variant collimator blurring in SPECT.

Authors:  W Xia; R M Lewitt; P R Edholm
Journal:  IEEE Trans Med Imaging       Date:  1995       Impact factor: 10.048

4.  Verification of the sensitivity and resolution dependence on the incidence angle for slit-slat collimation.

Authors:  J R Novak; A S Ayan; R Accorsi; S D Metzler
Journal:  Phys Med Biol       Date:  2008-01-23       Impact factor: 3.609

5.  SPRINT: A Stationary Detector Single Photon Ring Tomograph for Brain Imaging.

Authors:  W L Rogers; N H Clinthorne; J Stamos; K F Koral; R Mayans; J W Keyes; J J Williams; W P Snapp; G F Knoll
Journal:  IEEE Trans Med Imaging       Date:  1982       Impact factor: 10.048

6.  SPRINT II: a second generation single photon ring tomograph.

Authors:  W L Rogers; N H Clinthorne; L Shao; P Chiao; Y Ding; J A Stamos; K F Koral
Journal:  IEEE Trans Med Imaging       Date:  1988       Impact factor: 10.048

7.  The geometric transfer function for cone and fan beam collimators.

Authors:  B M Tsui; G T Gullberg
Journal:  Phys Med Biol       Date:  1990-01       Impact factor: 3.609

8.  Derivation and validation of a sensitivity formula for slit-slat collimation.

Authors:  R Accorsi; J R Novak; A S Ayan; S D Metzler
Journal:  IEEE Trans Med Imaging       Date:  2008-05       Impact factor: 10.048

9.  Improved estimation of the detector response function for converging beam collimators.

Authors:  E C Frey; B M Tsui; G T Gullberg
Journal:  Phys Med Biol       Date:  1998-04       Impact factor: 3.609

10.  Compensation of spatial system response in SPECT with conjugate gradient reconstruction technique.

Authors:  A R Formiconi; A Pupi; A Passeri
Journal:  Phys Med Biol       Date:  1989-01       Impact factor: 3.609

View more
  5 in total

1.  Analytic derivation of pinhole collimation sensitivity for a general source model using spherical harmonics.

Authors:  Yu-Sheng Li; James E Oldendick; Wei Chang
Journal:  Phys Med Biol       Date:  2010-04-19       Impact factor: 3.609

2.  Slit-Slat and Multislit-Slat Collimator Design and Experimentally Acquired Phantom Images from a Rotating Prototype.

Authors:  Scott D Metzler; Roberto Accorsi; Ahmet S Ayan; Ronald J Jaszczak
Journal:  IEEE Trans Nucl Sci       Date:  2010-02-01       Impact factor: 1.679

3.  LOR-interleaving image reconstruction for PET imaging with fractional-crystal collimation.

Authors:  Yusheng Li; Samuel Matej; Joel S Karp; Scott D Metzler
Journal:  Phys Med Biol       Date:  2015-01-02       Impact factor: 3.609

4.  Fourier rebinning and consistency equations for time-of-flight PET planograms.

Authors:  Yusheng Li; Michel Defrise; Samuel Matej; Scott D Metzler
Journal:  Inverse Probl       Date:  2016-07-06       Impact factor: 2.407

5.  Finding Optimized Conditions of Slit-Slat and Multislit-Slat Collimation for Breast Imaging.

Authors:  Daekwang Kau; Scott D Metzler
Journal:  IEEE Trans Nucl Sci       Date:  2012-02-01       Impact factor: 1.679

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.