Literature DB >> 19673185

Multidivergent-beam stationary cardiac SPECT.

Gengsheng L Zeng1, Andrew M Stevens.   

Abstract

This article develops a stationary cardiac single photon emission computed tomography (SPECT) system using a novel multidivergent-beam collimator. This stationary SPECT system is inexpensive to build, small, and able to acquire true dynamic SPECT data. Stationary cardiac SPECT systems with multipinhole technology already exist. The proposed approach is to replace the multipinhole collimators with the originally designed multidivergent-beam collimators. The motivation for replacing the pinhole technology by divergent-beam technology is based on the following facts. The resolution/sensitivity trade-off for the pinhole is excellent (good resolution and good sensitivity) only in small object (e.g., small animal) imaging when it operates in the image magnifying mode. However, in large object (e.g., human) imaging, the resolution/sensitivity trade-off is poor (poor resolution and poor sensitivity) when the pinhole operates in the image reducing mode. In a stationary system, the number of angular views is limited; thus, image reduction is necessary to obtain more view angles. In this image reducing situation, divergent-beam collimation is able to provide better resolution and detection sensitivity than pinhole collimation. Computer simulations are carried out to verified the claims.

Entities:  

Mesh:

Year:  2009        PMID: 19673185      PMCID: PMC2832036          DOI: 10.1118/1.3134245

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  7 in total

1.  Analytic determination of pinhole collimator sensitivity with penetration.

Authors:  S D Metzler; J E Bowsher; M F Smith; R J Jaszczak
Journal:  IEEE Trans Med Imaging       Date:  2001-08       Impact factor: 10.048

2.  Analytic determination of the resolution-equivalent effective diameter of a pinhole collimator.

Authors:  Roberto Accorsi; Scott D Metzler
Journal:  IEEE Trans Med Imaging       Date:  2004-06       Impact factor: 10.048

3.  A novel approach to multipinhole SPECT for myocardial perfusion imaging.

Authors:  Tobias Funk; Dennis L Kirch; John E Koss; Elias Botvinick; Bruce H Hasegawa
Journal:  J Nucl Med       Date:  2006-04       Impact factor: 10.057

4.  SPRINT II: a second generation single photon ring tomograph.

Authors:  W L Rogers; N H Clinthorne; L Shao; P Chiao; Y Ding; J A Stamos; K F Koral
Journal:  IEEE Trans Med Imaging       Date:  1988       Impact factor: 10.048

5.  Comparison of simultaneous dual-isotope multipinhole SPECT with rotational SPECT in a group of patients with coronary artery disease.

Authors:  Peter P Steele; Dennis L Kirch; John E Koss
Journal:  J Nucl Med       Date:  2008-06-13       Impact factor: 10.057

6.  A low-energy multihole converging collimator compared with a pinhole collimator.

Authors:  R A Moyer
Journal:  J Nucl Med       Date:  1974-02       Impact factor: 10.057

7.  A diverging collimator for gamma-ray imaging cameras.

Authors:  G Muehllehner
Journal:  J Nucl Med       Date:  1969-04       Impact factor: 10.057

  7 in total
  2 in total

1.  Ready, shoot, aim? Summary justice for small hearts in nuclear cardiology.

Authors:  Guido Germano; Paul B Kavanagh
Journal:  J Nucl Cardiol       Date:  2016-05-20       Impact factor: 5.952

2.  New Imaging Protocols for New Single Photon Emission CT Technologies.

Authors:  Piotr J Slomka; Daniel S Berman; Guido Germano
Journal:  Curr Cardiovasc Imaging Rep       Date:  2010-04-20
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.