An evaluation of a two-dimensional array detector for high resolution PET.

M Dahlbom1, E J Hoffman.   

Abstract

A two-dimensional array detector system, consisting of 4x8 matrices of bismuth germanate (BGO) crystals coupled to four photomultipliers, was evaluated. Coincidence timing resolution of a pair of array detectors was 6.1 ns FWHM and 11.3 ns FWTM. Energy resolution per individual crystal ranged from 16.8 to 24.1% FWHM at 511 keV for an amplitude variation of a factor of 2.8. The signals from the photomultipliers were summed pairwise, the pairs in each dimension subtracted, and the differences divided by the amplitude of the signal summed from all four photomultipliers. The resulting two-pulse-height spectra contained peaks corresponding to the row or column containing the detector of interaction. Six conditions of detector identification were tested. The correct identification of detector ranged from 76% to 87% of the events. The largest single factor in improving crystal identification and spatial resolution was energy discrimination.

Entities:  

Year:  1988        PMID: 18230478     DOI: 10.1109/42.14508

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  9 in total

Review 1.  3D acquisition and reconstruction in positron emission tomography.

Authors:  D L Bailey
Journal:  Ann Nucl Med       Date:  1992-08       Impact factor: 2.668

2.  Realistic PET Monte Carlo Simulation With Pixelated Block Detectors, Light Sharing, Random Coincidences and Dead-Time Modeling.

Authors:  Bastein Guérin; Georges El Fakhri
Journal:  IEEE Trans Nucl Sci       Date:  2008       Impact factor: 1.679

3.  Parametric positioning of a continuous crystal PET detector with depth of interaction decoding.

Authors:  T Ling; T H Burnett; T K Lewellen; R S Miyaoka
Journal:  Phys Med Biol       Date:  2008-03-10       Impact factor: 3.609

4.  Multiplexing strategies for monolithic crystal PET detector modules.

Authors:  L A Pierce; W C J Hunter; D R Haynor; L R MacDonald; P E Kinahan; R S Miyaoka
Journal:  Phys Med Biol       Date:  2014-08-22       Impact factor: 3.609

Review 5.  Assessment of myocardial perfusion and function with PET and PET/CT.

Authors:  Mouaz H Al-Mallah; Arkadiusz Sitek; Stephen C Moore; Marcelo Di Carli; Sharmila Dorbala
Journal:  J Nucl Cardiol       Date:  2010-06       Impact factor: 5.952

6.  Performance evaluation of the inveon dedicated PET preclinical tomograph based on the NEMA NU-4 standards.

Authors:  Qinan Bao; Danny Newport; Mu Chen; David B Stout; Arion F Chatziioannou
Journal:  J Nucl Med       Date:  2009-02-17       Impact factor: 10.057

7.  Development of a Cost-Effective Modular Pixelated NaI(Tl) Detector for Clinical SPECT Applications.

Authors:  Mike Rozler; Haoning Liang; Wei Chang
Journal:  IEEE Trans Nucl Sci       Date:  2012-08-30       Impact factor: 1.679

8.  Crystal identification in positron emission tomography using nonrigid registration to a Fourier-based template.

Authors:  Abhijit J Chaudhari; Anand A Joshi; Spencer L Bowen; Richard M Leahy; Simon R Cherry; Ramsey D Badawi
Journal:  Phys Med Biol       Date:  2008-08-22       Impact factor: 3.609

9.  Spatial distortion correction and crystal identification for MRI-compatible position-sensitive avalanche photodiode-based PET scanners.

Authors:  Abhijit J Chaudhari; Anand A Joshi; Yibao Wu; Richard M Leahy; Simon R Cherry; Ramsey D Badawi
Journal:  IEEE Trans Nucl Sci       Date:  2009-06-01       Impact factor: 1.679

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.